Eaton BR Series Main Circuit B...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$844.33

Eaton BR Series Main Circuit Breaker Loadcenter 100A Single-Phase 120/240V with Plug-On Neutral

(No reviews yet) Write a Review

Model: BRP10B100
$844.33

In Stock (leaves warehouse same day if ordered before 3pm ET)

$844.33
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton BR Series Main Circuit Breaker Loadcenter 100A Single-Phase 120/240V with Plug-On Neutral

Professional electrical distribution with plug-on neutral technology

The Eaton BR Series Main Circuit Breaker Loadcenter delivers reliable 100A single-phase electrical distribution at 120/240V with advanced plug-on neutral main circuit breaker technology. This metallic gray enclosure loadcenter features aluminum bus construction with 25 kA bus rating and 10 kAIC interrupt rating, designed for use with Type BR 1-inch breakers and accommodating #6-1/0 AWG Cu/Al wire connections.

Professional Features & Benefits

  • 100A Single-Phase Rating: Provides robust electrical distribution capacity for residential and light commercial applications
  • Plug-On Neutral Technology: Simplifies installation and reduces wiring time with integrated neutral connection system
  • 25 kA Bus Rating: Delivers high fault current capacity for enhanced system protection and reliability
  • 10 kAIC Interrupt Rating: Ensures safe circuit protection under fault conditions with proven interrupting capability
  • Aluminum Bus Construction: Offers excellent conductivity and corrosion resistance for long-term performance
  • Metallic Gray Enclosure: Provides durable protection with professional appearance and included cover
  • Feed-Through Lugs: Enables flexible installation options and downstream distribution capabilities

Technical Specifications

  • Accessories: Feed-through lugs
  • Bus Material: Aluminum
  • Bus Rating: 25 kA
  • Circuit Breaker Rating: 10 kAIC
  • Cover Type: Cover included
  • Enclosure Color: Gray
  • Enclosure Material: Metallic
  • Interrupt Rating: 10 kAIC
  • Item Quantity: 1
  • Mounting Method: Combination
  • Number Of Poles: Single-pole
  • Phase: Single-phase
  • Product Details: Plug-on neutral main circuit breaker loadcenter
  • Used With: Type BR 1-inch breakers
  • Voltage Rating: 120/240 V
  • Wire Size: #6-1/0 AWG Cu/Al

Professional Applications

  • Residential electrical service panels and distribution
  • Light commercial facility power distribution
  • Multi-unit residential properties
  • Professional office electrical systems
  • Retail establishment power distribution
  • Service upgrade and modernization projects

Why Choose Eaton Quality?

Eaton BR Series loadcenters deliver proven reliability with metallic enclosure construction, aluminum bus technology, and comprehensive circuit protection capabilities. The plug-on neutral design and feed-through lug accessories provide professional installation flexibility while maintaining the durability and performance standards expected from Eaton electrical distribution equipment.

Manufacturer Resources

Product Specs

Accessories:
Feed-through lugs
Bus Material:
Aluminum
Bus Rating:
25 kA
Circuit Breaker Rating:
10 kAIC
Cover Type:
Cover included
Enclosure Color:
Gray
Enclosure Material:
Metallic
Interrupt Rating:
10 kAIC
Item Quantity:
1
Mounting Method:
Combination
Number Of Poles:
Single-pole
Phase:
Single-phase
Product Details:
Plug-on neutral main circuit breaker loadcenter
Used With:
Type BR 1-inch breakers
Voltage Rating:
120/240 V
Wire Size:
#6-1/0 AWG Cu/Al
Department:
Electrical
Product Type:
Load Center
Product Group:
Load Centers & Panel Boards

Eaton BRP10B100 – Frequently Asked Questions

1) Will the Eaton BR loadcenter take Type CH breakers, or does it have to be BR?
Type BR 1-inch breakers only. The BR bus is a different geometry from Eaton's CH line, so CH breakers will not seat on it. If the panel you are replacing has CH breakers and you want to reuse them, this is the wrong enclosure. Anything you buy for this panel, single-pole, two-pole, GFCI or AFCI, needs to be a Type BR 1-inch breaker.
2) What size wire can I land on the main lugs of the Eaton BR 100A loadcenter?
The main terminals take #6 through 1/0 AWG, and they are rated for either copper or aluminum conductors. That range covers the usual 100A service conductor choices, so a 1/0 aluminum SER feed or a #4 copper feed both land directly without a splice or a reducer.
3) Can the Eaton BR 100A main breaker panel be mounted outside?
Both indoor and outdoor enclosures are offered, so pick the one that matches where it lands. An outdoor version is what you want on an exterior wall for a service entrance or a detached garage feed; the indoor version is for a basement, utility room, or interior wall. The enclosure is metallic and finished gray either way, and the cover comes with it.
4) How many circuits does the Eaton BR 100A loadcenter hold?
Space counts run 10, 12, 16, 20, and 30 one-inch spaces, with maximum circuit counts of 20, 24, 32, 45, and 50. The two numbers differ because tandem breakers put two circuits in one space where the bus allows it. Order by the space count if you are laying out full-size breakers, and by the maximum circuit count if you intend to use tandems to get more circuits out of the same box.
5) Is 10 kAIC enough interrupting rating for my service, or do I need a higher AIC panel?
The breaker interrupt rating is 10 kAIC and the bus is rated 25 kA. 10 kAIC covers the great majority of residential and light commercial services fed from a typical utility transformer. Where it does not is a large transformer close to the building or a high available-fault-current calculation from the utility, and on those jobs the engineer will call out a higher AIC panel or series-rated protection upstream. If the drawing states an available fault current above 10 kA at this panel, this is not the right loadcenter.
6) Does the Eaton BR 100A loadcenter work on 120/240V single-phase residential service?
Yes, that is exactly what it is built for: single-phase, 120/240V. Two hots and a neutral off the utility drop or the meter socket, giving you 120V circuits off either leg and 240V across both for ranges, dryers, water heaters, and HVAC. It is not a three-phase panel, so a 208Y/120 or 240V three-phase commercial service needs a different loadcenter.
7) What is plug-on neutral and does it change how I wire AFCI and GFCI breakers?
Plug-on neutral means the neutral connection is built into the bus, so a plug-on neutral AFCI or GFCI Type BR breaker picks up its neutral when you snap it on. There is no white pigtail to run back to the neutral bar. That takes a wire out of every dual-function circuit, which on a panel full of AFCIs is a real reduction in wire in the gutter. Standard breakers snap on the same way.
8) Can I feed a subpanel or a detached building off this Eaton BR 100A panel?
Feed-through lugs are the accessory that makes that straightforward. They give you a second set of lugs fed from the main, so you can carry power downstream to a subpanel, a garage, or a second distribution point without consuming breaker spaces for a feeder breaker. Size the downstream conductors to the 100A main and to the #6 to 1/0 AWG Cu/Al terminal range.
9) What does the X0, X1, X1R, X2, X3, X5 box size code on an Eaton BR loadcenter mean when I order?
That code is the enclosure box size, and it is a separate choice from the circuit count. Six are offered: X0, X1, X1R, X2, X3, and X5. Box size determines the physical footprint and the gutter space you get to work in, so on a rework where the panel drops into an existing wall opening or an existing cutout, the box code is the number that has to match, not just the breaker count. Confirm the box size against the opening before you order, because two panels with the same number of spaces can come in different boxes.
10) Can this panel be surface mounted, or is it flush only?
Combination mounting, so it goes in either way. Surface mount it on a finished basement wall or in a mechanical room with the conduit run on the face, or flush mount it between studs in a hallway or closet with the trim sitting tight to the drywall. Same enclosure, and the cover is included either way.
11) I manage a building with several Eaton BR panels. Will this match what is already installed?
If the existing panels are Eaton BR, yes. Any Type BR 1-inch breaker on your shelf drops into this panel, which means one stock of spares covers every unit instead of a separate bin per building. The enclosures are gray metallic with the cover included. Where it will not match is if the existing gear is Eaton CH, since CH breakers do not fit a BR bus.
12) Do I need a separate main breaker panel, or can I use a main lug loadcenter instead?
A main breaker version like this one has the 100A disconnect built into the enclosure, which is what you need when the panel is the service entrance equipment and code requires a service disconnect at that point. A main lug loadcenter has no built-in disconnect and is fed from an upstream breaker, so it suits a subpanel downstream of an existing service. If this panel is the first point of disconnect after the meter, the main breaker version is the one to order.
13) Is the bus in the Eaton BR loadcenter copper or aluminum, and does that matter for my install?
Aluminum bus. For a 100A residential or light commercial panel that is the standard construction and it carries the full rating. What it does affect is torque discipline: land your conductors at the marked torque value and re-check the terminations, because that is where aluminum terminations cause callbacks. The lugs are rated for both copper and aluminum conductors from #6 to 1/0 AWG, so the feed itself can be either metal.
How fast can I get the Eaton BRP10B100 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton BRP10B100 come with a warranty?
Absolutely. The Eaton BRP10B100 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton BRP10B100?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton BRP10B100 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.