Eaton CH 50A Three-Pole Thermal Magnetic Circuit Breaker with Common Trip
Professional 240V Circuit Protection for Type CH Loadcenters
The Eaton CH 50A three-pole thermal magnetic circuit breaker delivers reliable electrical protection with common trip functionality for Type CH loadcenters. This HACR-rated circuit breaker features 10 kAIC interrupt rating and 240V operation, accommodating #10-1/0 AWG Cu/Al wire connections in a compact 3/4-inch standard design that requires three spaces in the panel.
Professional Features & Benefits
- 50A Rating: Provides robust current capacity for high-demand three-phase electrical loads and equipment protection.
- Three-Pole Common Trip: Ensures simultaneous disconnection of all three phases for enhanced safety and coordinated protection.
- 10 kAIC Interrupt Rating: Delivers reliable fault current interruption capability for residential and light commercial applications.
- 240V Operation: Optimized for standard three-phase voltage systems with proven thermal magnetic trip technology.
- HACR Rated: Certified for heating, air conditioning, and refrigeration equipment protection with UL 489 compliance.
- #10-1/0 AWG Compatibility: Accommodates both copper and aluminum conductors for flexible installation options.
- Compact 3/4-Inch Design: Space-efficient form factor maximizes panel capacity while maintaining full protection performance.
Technical Specifications
- Amperage Rating: 50 A
- Catalog Notes: HACR rated, Three-Pole 240V Common Trip Requires Three 3/4-Inch Spaces
- Certifications: UL 489
- Circuit Breaker Type: CH
- Department: Electrical
- Interrupt Rating: 10 kAIC
- Main Circuit Breaker: CH
- Number Of Poles: Three-pole
- Product Details: Type CH 3/4-Inch standard circuit breaker
- Product Group: Electrical
- Product Height: 2.6 in
- Product Length Depth: 2.2 in
- Product Weight: .95 lb
- Product Width: 3.2 in
- Trip Type: Common breaker trip
- Used With: Type CH Loadcenters
- Voltage Rating: 240 V - 240 V
- Wire Size: #10-1/0 AWG Cu/Al
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- HVAC Equipment Protection
- Commercial Kitchen Equipment
- Industrial Motor Loads
- Refrigeration Systems
- Three-Phase Lighting Circuits
- Manufacturing Equipment
- Professional Workshop Power Distribution
Why Choose Eaton Quality?
Eaton circuit breakers deliver proven thermal magnetic protection technology with UL 489 certification and HACR rating for reliable performance. The compact design and common trip functionality provide professional-grade electrical protection you can trust for critical three-phase applications.
Manufacturer Resources
Product Specs
- Amperage Rating:
- 50 A
- Catalog Notes:
- HACR rated, Three-Pole 240V Common Trip Requires Three 3/4-Inch Spaces
- Certifications:
- UL 489
- Circuit Breaker Type:
- CH
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CH
- Number Of Poles:
- Three-pole
- Product Height:
- 2.6 in
- Product Length Depth:
- 2.2 in
- Product Weight:
- .95 lb
- Product Width:
- 3.2 in
- Trip Type:
- Common breaker trip
- Used With:
- Type CH Loadcenters
- Voltage Rating:
- 240 V - 240 V
- Wire Size:
- #10-1/0 AWG Cu/Al
- Product Group:
- Electrical
- Department:
- Electrical
- Product Details:
- Type CH 3/4-Inch standard circuit breaker