Eaton MTE Industrial Control Transformer, Copper Windings

(No reviews yet) Write a Review

Model: C0050E2AFB

In Stock (leaves warehouse same day if ordered before 3pm ET)

$260.64
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton MTE Industrial Control Transformer, Copper Windings

The Eaton MTE Industrial Control Transformer delivers reliable step-down control power for industrial machinery and control panels. Built with copper windings and epoxy-encapsulated construction, this transformer offers dual-voltage primary configurations that step down to a 120/115/110V secondary for control circuits. With a 50/60Hz operating range and a 130°C insulation system, the MTE Series is engineered for dependable performance in demanding industrial environments, and is cUL Certified and RoHS Compliant for use in code-regulated installations.

Key Features

  • Durable Construction: Copper windings paired with epoxy-encapsulated housing for long-term durability and moisture resistance.
  • Primary Voltage: Available in dual-voltage primary configurations to suit a range of supply systems.
  • Secondary Voltage: Steps down to 120/115/110V for control circuit compatibility.
  • Frequency Rating: Operates on standard 50/60Hz power systems.
  • Insulation System: 130°C insulation system standard, with a 55°C temperature rating for consistent operation under load.
  • Core Design: Laminations of high-quality silicon steel minimize core losses and optimize operating performance.
  • Molded-In Terminals: Molded-in terminals provide maximum durability and secure field wiring connections.
  • Factory-Mounted Fuse Block: Available with a factory-mounted two-pole primary fuse block for non-rejection type fuses.

Certifications & Compliance

  • cUL Certified
  • RoHS Compliant

Technical Specifications

  • Department: Electrical
  • Design: MTE
  • Coil Material: Copper windings
  • Primary Voltage: Dual-voltage primary configurations available
  • Secondary Voltage: 120/115/110V
  • Temperature Rating: 55°C
  • Insulation System: 130°C standard
  • Frequency: 50/60Hz operation
  • Modification: Factory-mounted two-pole primary fuse block for non-rejection type fuses

Typical Applications

  • Industrial and Commercial Control Panels
  • Machine Tool and Automation Control Circuits
  • Motor Control Centers and Starter Enclosures
  • OEM Equipment Requiring Stepped-Down Control Power
  • Panelboard and Control Cabinet Retrofits

Why Eaton?

Eaton's MTE Series industrial control transformers combine copper windings, epoxy-encapsulated construction, and high-quality silicon steel laminations to deliver dependable control power for demanding industrial applications. Backed by cUL Certification and RoHS Compliance, these transformers are built to support code-compliant, reliable performance in professional electrical installations.

Variant Specifications

Primary VoltageModelSKU
E2/E4 primary taps (C0050E2AFB/C0075E2AFB/C0100E4DFB)StandardC0050E2AFB
E5 primary taps (C0050E5EFB)C0050E5EFBC0050E5EFB

Manufacturer Resources

Product Specs

Department:
Electrical
Product Design:
MTE
Compliances:
RoHS Compliant
Temperature rating:
55°C
Coil material:
Copper windings
Product Group:
Power Distribution
Product Type:
Control Transformer
Product Subgroup:
Transformers
Product Width:
3 in
Certifications:
cUL Certified
Product Height:
4.04 in

Eaton C0050E2AFB – Frequently Asked Questions

1) What secondary voltage does the Eaton MTE control transformer put out for a control circuit?
The MTE Series steps down to a 120/115/110V secondary, which is what standard control circuits, relays, contactor coils and pilot devices in a panel run on. Primary side is dual-voltage, so the same unit covers two supply voltages depending on how you land the taps.
2) What is the difference between the Eaton C0050E2AFB and the C0050E5EFB?
Both are MTE control transformers with the same 120/115/110V secondary; the difference is the primary tap arrangement. The C0050E2AFB carries E2 primary taps (the same E2/E4 tap family as the C0075E2AFB and C0100E4DFB), and the C0050E5EFB carries E5 primary taps. Pick the one whose primary taps match your incoming supply voltage.
3) Does the Eaton MTE transformer come with a primary fuse block, or do I have to add one?
A factory-mounted two-pole primary fuse block is part of the build, sized for non-rejection type fuses. That means you do not need to find panel space for a separate fuse holder on the line side, but the fuses themselves are a separate item and must be non-rejection style to seat in the block.
4) Will an Eaton MTE control transformer work on a 50Hz machine imported from overseas?
Yes. The MTE Series is rated for 50/60Hz operation, so it runs on either a North American 60Hz supply or a 50Hz system on imported machine tools and OEM equipment.
5) Is the Eaton MTE control transformer approved for use in Canada?
It is cUL Certified and RoHS Compliant, which covers it for code-regulated installations on both sides of the border. Those are the only listings stated for the MTE Series.
6) Can this Eaton transformer handle a hot, dusty or damp machine shop environment?
The MTE is epoxy-encapsulated, which seals the windings against moisture and airborne contamination in shop and plant environments. It uses a 130 degree C insulation system with a 55 degree C temperature rise rating under load.
7) Can I use an Eaton MTE control transformer to retrofit an existing control cabinet?
That is one of its stated uses, along with motor control centers, starter enclosures, machine tool and automation control circuits, and OEM equipment needing stepped-down control power. For a retrofit, match the primary tap version (E2/E4 or E5) to the supply already feeding the cabinet and confirm the existing control devices run on 120/115/110V.
8) Are the windings on the Eaton MTE copper or aluminum?
Copper. Copper windings run cooler at a given load and hold terminal torque better over time than aluminum, which is why they are specified on control transformers feeding contactor coils that cycle constantly.
9) How do the wiring terminals attach on the Eaton MTE control transformer?
Terminals are molded into the encapsulated body rather than mounted on a separate strip, so there is nothing to loosen or shift when you land field wiring. The core is built from silicon steel laminations to hold down core losses on a circuit that sits energized all day.
How fast can I get the Eaton C0050E2AFB delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton C0050E2AFB come with a warranty?
Absolutely. The Eaton C0050E2AFB is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton C0050E2AFB?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton C0050E2AFB from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.