Eaton QBGF Quicklag Bolt-On Ground Fault Circuit Breaker, 15-50A, 5mA
The Eaton QBGF Quicklag Bolt-On Ground Fault Circuit Breaker delivers 5mA trip sensitivity for dependable personnel and equipment protection in residential and light commercial load centers. Available in 15A through 50A ratings, 1-pole and 2-pole configurations, and 10 kAIC or 22 kAIC interrupting ratings at 120/240V, this bolt-on breaker is UL 489 Listed and HACR Rated, making it well suited to panelboards and load centers that require sensitive ground fault protection in wet and damp locations.
Key Features
- Amperage Range 15-50A: Covers common branch circuit loads, including lighting, appliances, HVAC equipment, and general-purpose circuits.
- 5mA Trip Sensitivity: Highly sensitive ground fault detection meets NEC requirements for personnel protection in wet and damp locations.
- 1-Pole and 2-Pole Configurations: Single-pole for 120V branch circuits; double-pole for 240V or 120/240V loads including HVAC and large appliances.
- 120/240V Rating: Sized for standard residential and light commercial branch circuit voltages.
- 10 kAIC and 22 kAIC Interrupting Ratings: 10 kAIC for standard residential panels; 22 kAIC for higher fault-current commercial and light-industrial applications.
- Bolt-On Connection: Secure, vibration-resistant mounting for long-term reliability in load centers and panelboards.
- HACR Rated: Listed for heating, air conditioning, and refrigeration equipment per NEC 440 requirements.
Certifications & Compliance
- UL 489 Listed
- HACR Rated
- Suitable for Wet and Damp Locations
Technical Specifications
- Compliances: Contact Manufacturer
- Trip Rating: 5 mA
- Voltage Rating: 120/240 V
Typical Applications
- Residential Load Centers — Bathrooms, Kitchens, Garages, Outdoor Circuits
- Commercial Tenant Spaces and Multi-Family Panels
- HVAC Equipment Branch Circuits (HACR Rated)
- Light Commercial and Institutional Electrical Systems
- Wet and Damp Location Branch Circuits Requiring Ground Fault Protection
Why Eaton?
Eaton engineers the QBGF Quicklag Ground Fault Circuit Breaker for dependable, code-compliant performance in demanding electrical environments. With UL 489 listing, HACR certification, and a rugged bolt-on mounting design, this breaker protects personnel and equipment through sensitive 5mA ground fault detection across a wide range of amperage, pole, and interrupting rating combinations. Electrical professionals can specify Eaton QBGF breakers with confidence for new construction and panel upgrades, relying on 10 kAIC and 22 kAIC interrupting ratings to match the fault-current demands of residential and light commercial installations. The bolt-on design resists loosening from vibration over time, helping panelboards and load centers maintain secure connections through years of service in both new construction and retrofit panel upgrades where sensitive ground fault protection is required by code.
Manufacturer Resources
Product Specs
- Catalog Notes:
- HACR rated
- Certifications:
- UL 489
- Compliances:
- Contact Manufacturer
- Connection:
- Bolt-on
- Mounting Method:
- Bolt-on
- Trip Rating:
- 5 mA
- Voltage Rating:
- 120/240V
- Department:
- Electrical
- Product Group:
- Circuit Protection
- Product Type:
- GFCI/AFCI Circuit Breaker
- Product Subgroup:
- Circuit Breakers