Eaton Type BR Three-Phase Main...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$2,146.19

Eaton Type BR Three-Phase Main Lug Loadcenter 200A Copper Bus 42-Circuit Metallic Enclosure

(No reviews yet) Write a Review

Model: 3BR3042LC200
$2,146.19

In Stock (leaves warehouse same day if ordered before 3pm ET)

$2,146.19
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton Type BR Three-Phase Main Lug Loadcenter

Professional Three-Phase Power Distribution Solution

The Eaton Type BR Three-Phase Main Lug Loadcenter delivers reliable 200A power distribution with copper bus construction and metallic enclosure durability. This professional-grade loadcenter accommodates 42 circuits with three-phase capability, supporting 208Y/120 and 240V applications with 25 kAIC interrupt rating for comprehensive electrical distribution needs.

Professional Features & Benefits

  • 200A Service Rating: Provides substantial power capacity for demanding three-phase electrical distribution requirements.
  • Copper Bus Construction: Ensures superior conductivity and long-term reliability with excellent corrosion resistance.
  • 42-Circuit Capacity: Accommodates extensive branch circuit requirements for comprehensive power distribution.
  • 25 kAIC Interrupt Rating: Delivers robust fault current protection for enhanced electrical safety.
  • Three-Phase Configuration: Supports balanced power distribution for commercial and industrial applications.
  • Metallic Enclosure: Provides durable protection with professional appearance and structural integrity.
  • Type BR Compatibility: Works exclusively with Type BR 1-inch breakers for consistent system performance.

Technical Specifications

  • Amperage Rating: 200 A
  • Bus Material: Copper
  • Cover Type: Cover included
  • Enclosure Material: Metallic
  • Interrupt Rating: 25 kAIC
  • Main Circuit Breaker: BWH
  • Mounting Method: Combination
  • Number Of Circuits: 42
  • Number Of Wires: 4
  • Phase: Three-phase
  • Product Width: 14.31 in
  • Special Features: No feed-thru lugs
  • Used With: Type BR 1-inch breakers
  • Voltage Rating: 208Y/120, 240V

Professional Applications

  • Commercial Facilities requiring three-phase power distribution
  • Light Industrial installations with multiple circuit requirements
  • Multi-Unit Properties with substantial electrical loads
  • Professional Offices with comprehensive power needs
  • Retail Establishments requiring reliable electrical distribution
  • Service Buildings with balanced three-phase requirements

Why Choose Eaton Quality?

Eaton loadcenters provide proven reliability with copper bus construction and metallic enclosure durability. The 25 kAIC interrupt rating and Type BR breaker compatibility ensure consistent performance and safety in professional electrical distribution applications.

Manufacturer Resources

Product Specs

Amperage Rating:
200 A
Bus Material:
Copper
Cover Type:
Cover included
Enclosure Material:
Metallic
Interrupt Rating:
25 kAIC
Main Circuit Breaker:
BWH
Mounting Method:
Combination
Number Of Circuits:
42
Number Of Wires:
4
Phase:
Three-phase
Product Width:
14.31 in
Special Features:
No feed-thru lugs
Used With:
Type BR 1-inch breakers
Voltage Rating:
208Y/120, 240V
Department:
Electrical
Product Type:
Load Center
Product Group:
Load Centers & Panel Boards

Eaton 3BR3042LC200 – Frequently Asked Questions

1) Can I use this Eaton three-phase loadcenter on a 208Y/120 volt wye service?
Yes. The Eaton Type BR three-phase main lug loadcenter is rated 208Y/120 and 240V, three-phase, four wire. The four-wire rating means it takes the three phase conductors plus a neutral, so you can pull 120V single-pole branch circuits off it as well as 208V two-pole and three-pole loads. On a 240V delta service it works too, but be aware of the high leg if your system is a corner-grounded or high-leg delta.
2) What breakers fit an Eaton Type BR 42-circuit loadcenter?
Type BR 1-inch breakers only. This is Eaton's BR bus, not CH, and the two are not interchangeable even though both are Eaton. A CH breaker will not seat correctly on a BR bus. Because the panel is three-phase, three-pole BR breakers are what you use for balanced 208V or 240V three-phase loads, and single-pole BR breakers land 120V circuits off any one phase.
3) Is there a main breaker in this Eaton 200A loadcenter, or is it main lug only?
It is main lug only. Power lands directly on the lugs, so overcurrent protection for the 200A feeder has to come from upstream, typically the main disconnect or the breaker in the panel feeding it. If your installation needs a main disconnect in the can itself, a BWH main breaker is the one that goes with this panel, ordered separately. Most inspectors will want main lug panels fed from a device with a disconnecting means, so check how the feeder originates before you order.
4) What is the difference between the 30-space and 42-space versions of this Eaton BR three-phase panel?
Both are rated for a maximum of 42 circuits, but they differ in physical spaces. The 30-space boxes use part numbers like 3BR3042LC200 (indoor) and 3BR3042LC200R (outdoor); the 42-space boxes are 3BR4242LC200 and 3BR4242LC200R. On a 30-space box you get to 42 circuits by using tandem BR breakers where permitted; on a 42-space box every circuit can be a full-size single-pole. If you are running mostly two-pole and three-pole breakers, go with 42 spaces, because multi-pole breakers cannot tandem.
5) Which Eaton BR three-phase part number do I order for an outdoor wall?
The outdoor boxes carry an R suffix: 3BR3042LC200R for the 30-space box and 3BR4242LC200R for the 42-space. Drop the R and you have the indoor versions, 3BR3042LC200 and 3BR4242LC200. All four are 200A, copper bus, metallic enclosure, with the cover included.
6) Is 25 kAIC enough for my service, and what does that rating cover?
The panel is rated 25 kAIC, which is the short-circuit current it can safely interrupt at its terminals. On most commercial 208Y/120 services fed from a utility transformer of moderate size, available fault current sits below that, but on a large pad-mount transformer or a short feeder run it can exceed 25 kA. Get the available fault current from the utility or a short-circuit study for your service point. If it comes back above 25 kA, this panel is not the right choice and you need a higher-AIC panelboard or upstream current-limiting protection.
7) Can I feed another panel through this Eaton loadcenter?
No. It is built with no feed-thru lugs, so you cannot land a second set of conductors on the bus to carry power downstream. To feed a subpanel, you have to run it off a branch breaker in the panel instead. If your design depends on feed-thru, pick a loadcenter that specifically lists feed-thru lugs.
8) Can I use this 200A three-phase loadcenter to replace a single-phase panel in an apartment building?
Not as a direct swap. This is a three-phase, four-wire panel with a three-phase bus arrangement; a single-phase 120/240 panel has a two-phase bus. Feeding a three-phase bus from a single-phase service leaves one leg dead and the circuits on it with no power. If your building service is single-phase, order a single-phase BR loadcenter instead. Where the building does have a 208Y/120 three-phase service, this is the right configuration for a house panel or a tenant distribution panel.
9) Will this Eaton BR panel fit between studs on 16-inch centers?
The enclosure is 14.31 inches wide, so it fits in a standard 16-inch on-center stud bay with room for the box sides. Mounting is combination, meaning it can be surface mounted or flush mounted, which is what you need for a flush-in-the-wall install in a finished office or tenant space. The cover ships with the panel.
10) Copper bus versus aluminum bus in a loadcenter, does it matter for a commercial install?
This Eaton BR three-phase panel uses a copper bus. Copper has higher conductivity than aluminum for the same cross section and does not creep the way aluminum can under thermal cycling, which matters in a panel that runs loaded for long stretches in a retail or light industrial building. Some specs and some institutional standards call out copper bus explicitly, so if your drawing says copper bus, this one meets that line.
11) Do I need a separate ground bar or neutral kit with this Eaton three-phase loadcenter?
The panel is four-wire, so it accommodates the three phases plus a neutral. Where the equipment grounding conductors must be kept separate from the neutral, which is the case in every subpanel downstream of the service disconnect, you need a ground bar kit, and that is ordered separately from the panel. Plan on one if this is not the service entrance panel.
12) Is the outdoor version of this Eaton loadcenter okay to mount on an exterior wall without a separate enclosure?
Yes, the R-suffix boxes (3BR3042LC200R and 3BR4242LC200R) are the outdoor configurations and come with their own metallic enclosure and cover, so they mount directly to an exterior wall. The non-R boxes are indoor only and should not be used outside or in a wet location. Everything else, the 200A rating, copper bus, 25 kAIC, and BR breaker compatibility, is the same across both.
How fast can I get the Eaton 3BR3042LC200 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton 3BR3042LC200 come with a warranty?
Absolutely. The Eaton 3BR3042LC200 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton 3BR3042LC200?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton 3BR3042LC200 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.