Mersen A2D-R Class RK1 Time-Delay Fuse 100A 250VAC/250VDC with SmartSpot Indication
Professional Time-Delay Protection with Visual Indication Technology
The Mersen A2D-R Class RK1 time-delay fuse delivers reliable overcurrent protection for 100A applications at 250VAC/250VDC. Featuring SmartSpot visual indication technology and blade terminal design, this Amp-Trap 2000 series fuse provides professional-grade protection with clear status monitoring for critical electrical systems.
Professional Features & Benefits
- 100A Current Rating: Handles substantial electrical loads while providing precise overcurrent protection for demanding applications.
- Class RK1 Performance: Delivers superior current-limiting characteristics and reduced let-through energy for enhanced system protection.
- Time-Delay Characteristic: Allows temporary overloads while protecting against sustained overcurrent conditions, ideal for motor and inductive load applications.
- SmartSpot Visual Indication: Provides immediate visual confirmation of fuse status, enabling quick identification of blown fuses for faster maintenance.
- 250VAC/250VDC Dual Rating: Versatile voltage compatibility for both AC and DC applications with consistent protection performance.
- 200 kA Breaking Capacity: Exceptional fault current interruption capability ensures reliable protection even under severe fault conditions.
- Blade Terminal Design: Tin-plated copper terminals with clip mounting provide secure connections and easy installation.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 100 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Blade
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK1
- Indication System: Yes
- Indication System Type: SmartSpot�
- Mounting Method: Clip
- Product Length: 5.88 in
- Product Weight: 0.295 lb
- Rated Voltage Ac Ul: 250 V
- Rated Voltage Dc Ul: 250 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the fuse in a suitable fuse holder or disconnect with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire according to the provided 250VAC/250VDC voltage specifications and 100A current rating.
- Configure any available load management or control features as supported by the provided specifications.
- Test fuse installation and verify proper SmartSpot indication functionality before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Motor Control Centers and Industrial Equipment Protection
- Commercial HVAC Systems and Building Services
- Power Distribution Panels and Switchgear
- Manufacturing and Process Control Equipment
- Emergency Power Systems and UPS Applications
- Renewable Energy and Battery Storage Systems
- Critical Infrastructure and Data Centers
Why Choose Mersen Quality?
Mersen A2D-R fuses combine proven Class RK1 current-limiting technology with innovative SmartSpot indication for enhanced system reliability. The PolyTube insulating material and tin-plated copper terminals ensure long-term performance, while RoHS compliance demonstrates commitment to environmental responsibility. Trust Mersen's engineering excellence for critical overcurrent protection applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 100 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Blade
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK1
- Indication System:
- Yes
- Indication System Type:
- SmartSpot®
- Mounting Method:
- Clip
- Product Length:
- 5.88 in
- Product Weight:
- 0.295 lb
- Rated Voltage Ac Ul:
- 250 V
- Rated Voltage Dc Ul:
- 250 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay