Mersen A2D-R Class RK1 Time-Delay Fuse 50A 250VAC/250VDC with SmartSpot Indication
Professional Time-Delay Protection with Visual Indication Technology
The Mersen A2D-R Class RK1 time-delay fuse delivers reliable overcurrent protection for 50A applications at 250VAC/250VDC. Featuring SmartSpot visual indication technology and ferrule terminals with tin-plated copper construction, this Amp-Trap 2000 series fuse provides professional-grade protection with clear status monitoring for critical electrical systems.
Professional Features & Benefits
- 50A Current Rating: Provides precise overcurrent protection for medium-duty electrical circuits and equipment applications.
- Class RK1 Time-Delay: Offers superior selectivity and coordination while allowing temporary overloads, reducing nuisance tripping in motor and inductive load applications.
- SmartSpot Visual Indication: Enables quick visual identification of blown fuses, reducing troubleshooting time and improving maintenance efficiency.
- 200 kA Breaking Capacity: Delivers exceptional fault current interruption capability for demanding industrial and commercial applications.
- Dual Voltage Rating 250VAC/250VDC: Versatile design accommodates both AC and DC applications with consistent protection performance.
- Ferrule Terminal Design: Tin-plated copper terminals ensure reliable connections and corrosion resistance for long-term performance.
- RoHS Compliant Construction: Meets environmental standards while maintaining professional reliability and safety requirements.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 50 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Ferrule
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK1
- Indication System: Yes
- Indication System Type: SmartSpot�
- Mounting Method: Clip
- Product Length: 3 in
- Product Weight: 0.119 lb
- Rated Voltage Ac Ul: 250 V
- Rated Voltage Dc Ul: 250 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Motor Control Centers and Industrial Equipment Protection
- Commercial HVAC and Lighting Systems
- Power Distribution Panels and Switchgear
- Process Control and Automation Equipment
- Emergency Power and UPS Systems
- Manufacturing and Production Facilities
- Data Centers and Critical Infrastructure
Why Choose Mersen Quality?
Mersen A2D-R fuses combine proven Class RK1 time-delay technology with advanced SmartSpot indication systems and RoHS compliant construction. The tin-plated copper ferrule terminals and PolyTube insulating material ensure reliable performance and long service life in demanding professional applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 50 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Ferrule
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK1
- Indication System:
- Yes
- Indication System Type:
- SmartSpot®
- Mounting Method:
- Clip
- Product Length:
- 3 in
- Product Weight:
- 0.119 lb
- Rated Voltage Ac Ul:
- 250 V
- Rated Voltage Dc Ul:
- 250 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay