Mersen A2D-R Class RK1 Time-Delay Fuse 15A 250VAC/250VDC with SmartSpot Indication
Professional Amp-Trap 2000 Series Circuit Protection with Visual Indication
Mersen A2D-R Class RK1 Time-Delay Fuse delivers reliable circuit protection for 15A applications at 250VAC/250VDC. This professional-grade fuse features SmartSpot visual indication system, ferrule terminals with tin-plated copper construction, and PolyTube insulating material for dependable performance in demanding electrical environments.
Professional Features & Benefits
- 15A Current Rating: Provides precise overcurrent protection for medium-duty electrical circuits and equipment applications.
- Class RK1 Performance: Delivers superior current-limiting characteristics with high interrupting capacity for enhanced system protection.
- Time-Delay Characteristic: Allows temporary overloads while providing fast fault clearing, ideal for motor and inductive load applications.
- 250VAC/250VDC Dual Rating: Versatile voltage compatibility for both AC and DC circuit protection requirements.
- SmartSpot Visual Indication: Provides clear visual confirmation of fuse status, simplifying maintenance and troubleshooting procedures.
- 200kA Breaking Capacity: High fault current interrupting capability ensures reliable protection even under severe fault conditions.
- Ferrule Terminal Design: Tin-plated copper terminals ensure secure connections and excellent conductivity for long-term reliability.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 15 A
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Ferrule
- Frequency Hz: 50/60 Hz
- Fuse Class: Class RK1
- Indication System: Yes
- Indication System Type: SmartSpot�
- Mounting Method: Clip
- Product Length: 2 in
- Product Weight: 0.037 lb
- Rated Voltage Ac Ul: 250 V
- Rated Voltage Dc Ul: 250 V
- Rohs Compliant: Yes
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the fuse in a suitable fuse holder or disconnect with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Motor Control Centers and Industrial Equipment Protection
- Commercial HVAC and Lighting Circuit Protection
- Power Distribution Panels and Switchgear Applications
- Process Control and Automation System Protection
- Renewable Energy and Battery System Applications
- Emergency Power and UPS System Protection
- Manufacturing and Production Equipment Circuits
Why Choose Mersen Quality?
Mersen A2D-R fuses deliver proven reliability with RoHS compliant construction and professional-grade materials. The SmartSpot indication system and robust PolyTube insulation ensure dependable performance and simplified maintenance for critical electrical protection applications.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 15 A
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Ferrule
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK1
- Indication System:
- Yes
- Indication System Type:
- SmartSpot®
- Mounting Method:
- Clip
- Product Length:
- 2 in
- Product Weight:
- 0.037 lb
- Rated Voltage Ac Ul:
- 250 V
- Rated Voltage Dc Ul:
- 250 V
- Rohs Compliant:
- Yes
- Speed Characteristic:
- Time Delay