Mersen Class RK1 Time-Delay Fuse 5A 600VAC/600VDC Ferrule Terminal Amp-Trap 2000 Series
Professional Class RK1 Time-Delay Protection for Critical Circuit Applications
Mersen Class RK1 Time-Delay Fuse delivers superior circuit protection with 5A rating and dual 600VAC/600VDC voltage capability. This professional-grade Amp-Trap 2000 series fuse features ferrule terminal construction with tin-plated copper connections and PolyTube insulating material for reliable performance in demanding electrical applications. The time-delay characteristic provides enhanced motor starting protection while maintaining fast fault clearing capability.
Professional Features & Benefits
- Class RK1 Rating: Provides superior current-limiting performance and enhanced safety with reduced let-through energy during fault conditions.
- 5A Time-Delay Characteristic: Allows temporary overloads during motor starting while providing fast protection against short circuits and sustained overloads.
- 600VAC/600VDC Dual Rating: Versatile voltage capability supports both AC and DC applications up to 600V for maximum installation flexibility.
- 200 kA Breaking Capacity: High interrupting rating ensures reliable fault clearing in high-fault current systems and industrial applications.
- Ferrule Terminal Design: Tin-plated copper terminals provide secure connections and excellent conductivity with clip mounting method.
- PolyTube Insulating Material: Advanced body construction delivers superior arc resistance and mechanical strength for long-term reliability.
- Compact 5-inch Length: Space-efficient design fits standard fuse holders while maintaining full protection capability.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 5:00 AM
- Body Insulating Material: PolyTube
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Ferrule
- Frequency Hz : 50/60 Hz
- Fuse Class: Class RK1
- Mounting Method: Clip
- Product Length: 5 in
- Product Weight: 0.146 lb
- Rated Voltage Ac Ul: 600 V
- Rated Voltage Dc Ul: 600 V
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Motor Control Centers and Industrial Equipment Protection
- Commercial HVAC Systems and Building Services
- Power Distribution Panels and Switchgear
- Process Control and Automation Systems
- Emergency Power and UPS Applications
- Manufacturing and Production Equipment
- Critical Infrastructure and Data Centers
Why Choose Mersen Quality?
Mersen Class RK1 fuses deliver proven reliability with advanced PolyTube construction and tin-plated copper terminals for superior performance. The 200 kA breaking capacity and dual AC/DC rating provide professional-grade protection backed by UL listing and 50/60 Hz frequency compatibility for versatile installation requirements.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 5:00 AM
- Body Insulating Material:
- PolyTube
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Ferrule
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class RK1
- Mounting Method:
- Clip
- Product Length:
- 5 in
- Product Weight:
- 0.146 lb
- Rated Voltage Ac Ul:
- 600 V
- Rated Voltage Dc Ul:
- 600 V
- Speed Characteristic:
- Time Delay