Mersen ATQR Class CC Time-Delay Fuse 2.5A 600VAC/300VDC Ferrule Terminal Amp-Trap 2000 Series
Professional Circuit Protection with Superior Breaking Capacity
The Mersen ATQR Class CC Time-Delay Fuse delivers reliable circuit protection with 2.5A rating and dual voltage capability of 600VAC/300VDC. This professional-grade fuse features ferrule terminals with tin-plated copper construction and GMG body insulating material for dependable performance. With 200 kA AC breaking capacity and time-delay characteristics, this Amp-Trap 2000 series fuse provides superior protection for sensitive electrical circuits and equipment.
Professional Features & Benefits
- 2.5A Ampere Rating: Provides precise current protection for sensitive circuits and equipment applications.
- Class CC Design: Ensures current-limiting protection with rejection features to prevent incorrect fuse installation.
- Time-Delay Characteristics: Allows temporary overloads while providing fast protection against short circuits and sustained overcurrent conditions.
- 200 kA Breaking Capacity: Delivers exceptional fault current interruption capability for high-performance electrical systems.
- Dual Voltage Rating: Supports both 600VAC and 300VDC applications for versatile installation requirements.
- Ferrule Terminal Design: Provides secure connection with tin-plated copper terminals for reliable electrical contact and corrosion resistance.
- GMG Body Construction: Features high-quality insulating material for enhanced safety and durability in demanding environments.
Technical Specifications
- Ac Max I R Breaking Capacity I1: 200 kA
- Ac Or Dc: AC/DC
- Ampere Rating: 2.5 A
- Body Insulating Material: GMG
- Connection Terminal Material: Tin-Plated Copper
- Connection Terminal Type: Ferrule
- Frequency Hz : 50/60 Hz
- Fuse Class: Class CC
- Mounting Method: Clip
- Product Length: 1.5 in
- Product Weight: 0.017 lb
- Rated Voltage Ac Ul: 600 V
- Rated Voltage Dc Ul: 300 V
- Speed Characteristic: Time Delay
Installation & Operation
- Mount the fuse in a suitable Class CC fuse holder or disconnect with appropriate clearance and access for service.
- Connect circuit conductors to ferrule terminals following applicable electrical codes and manufacturer guidelines.
- Verify proper ampere rating and voltage compatibility with the protected circuit requirements.
- Configure any available fuse monitoring or indication features as supported by the installation.
- Test circuit protection functionality and verify proper fuse operation before energizing the system.
- Complete final inspection and establish ongoing maintenance practices for fuse monitoring and replacement.
Professional Applications
- Motor Control Centers and Industrial Control Panels
- Commercial HVAC and Lighting Systems
- Electronic Equipment and Sensitive Circuit Protection
- Power Distribution and Switchgear Applications
- Instrumentation and Control System Protection
- Renewable Energy and Battery System Applications
- Critical Infrastructure and Emergency Power Systems
Why Choose Mersen Quality?
Mersen delivers proven circuit protection technology with the ATQR Class CC Time-Delay Fuse, featuring 200 kA breaking capacity and dual voltage rating for reliable performance. The tin-plated copper ferrule terminals and GMG body construction ensure long-term durability and consistent protection in demanding electrical environments.
Manufacturer Resources
Product Specs
- Ac Max I R Breaking Capacity I1:
- 200 kA
- Ac Or Dc:
- AC/DC
- Ampere Rating:
- 2.5 A
- Body Insulating Material:
- GMG
- Connection Terminal Material:
- Tin-Plated Copper
- Connection Terminal Type:
- Ferrule
- Frequency Hz :
- 50/60 Hz
- Fuse Class:
- Class CC
- Mounting Method:
- Clip
- Product Length:
- 1.5 in
- Product Weight:
- 0.017 lb
- Rated Voltage Ac Ul:
- 600 V
- Rated Voltage Dc Ul:
- 300 V
- Speed Characteristic:
- Time Delay