B-Line Eaton series meter s, 2...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$4,962.47

B-Line Eaton series meter s, 200 A, Single meter position, Ring type, 3R, Underground, ANSI 61 gray painted, 010 kAIC, #6 - 250 MCM, MCB, 200 A, 2P,

(No reviews yet) Write a Review

Model: U2M2R F
Selected Model is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$4,962.47
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks
Eaton B-Line series meter breakers, 200 A, Single meter position, Ring type, 3R, Underground, ANSI 61 gray painted, 010 kAIC, #6 - 250 MCM, MCB, (1) 200 A, 2P, Galvanized steel, Flush mount, 4 jaws, 3 wires, 1 phase, 1Ø/3W, 120/240 V

Manufacturer Resources

Product Specs

Amperage Rating:
200A
Application:
Single meter position
Bus Material:
Aluminum
Certifications:
UL
Compliances:
EUSERC Approved
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
(1) 200 A, 2P
Phase:
Single-phase
Product Height:
25 in
Product Length Depth:
6 in
Product Weight:
37 lb
Product Width:
14 in
Voltage Rating:
120/240V
Department:
Electrical
Product Finish:
ANSI 61 gray paint
Product Material:
Galvanized steel

B-LINE U2M2R F – Frequently Asked Questions

1) Will the Eaton B-Line U2M2R F meter breaker work for a 200 amp single-family residential service at 120/240V?
Yes, for a single 200 A residential service. The U2M2R F is a single meter position combination meter socket and main breaker rated 200 A, single phase, 120/240 V, with one 200 A 2-pole main circuit breaker factory installed. It is a 4 jaw, 3 wire, 1 phase socket, which is the standard residential 1-phase/3-wire configuration. If the service is 3-phase or needs more than one meter, this is the wrong unit.
2) Is the U2M2R F meter socket fed from overhead or underground?
Underground. The U2M2R F is configured for an underground service lateral, so it has no hub or weatherhead provision for an overhead drop. For an overhead service you need the overhead-configured version of the meter breaker instead.
3) What conductor sizes will the lugs on this 200A B-Line meter breaker take?
The line and load terminations accept #6 through 250 MCM, which covers the usual 200 A service conductors including 4/0 aluminum and 2/0 copper. Bus is aluminum, so use a compatible antioxidant compound where your utility requires it on aluminum conductors.
4) Is this a ringless or ring type meter socket?
Ring type. The U2M2R F uses a sealing ring cover, so it only works where the utility specifies ring type sockets. Many utilities require ringless, and the two covers are not interchangeable, so confirm the utility's meter standard before ordering.
5) Can this meter breaker be mounted outdoors, and is it flush or surface mount?
The enclosure is Type 3R, which is rated for outdoor rain and sleet exposure. It is built as a flush mount unit, so it is set into the wall rather than surface mounted on the face of it, which matters for framing the opening during rough-in. Body is galvanized steel finished in ANSI 61 gray paint.
6) What rough opening do I need for the B-Line U2M2R F flush mount meter breaker?
The unit measures 25 in high, 14 in wide, and 6 in deep. Since it is a flush mount can, frame the wall opening to the 25 x 14 in face and make sure the cavity clears the 6 in depth. It weighs 37 lb, so a one-man set is realistic on a stud wall.
7) Does this meter breaker meet utility submittal requirements, and what is its short circuit rating?
It is UL listed and EUSERC approved, which is what most western utilities ask for on a meter socket submittal. Short circuit interrupting rating is 10 kAIC, so verify the available fault current at the service point does not exceed that.
8) Does the U2M2R F include branch breaker spaces for a load center?
No. It is a meter socket combined with a single 200 A 2-pole main circuit breaker only, so it serves as the service disconnect. Branch circuits need a separate panelboard fed from the 200 A main.
9) What is the exact part number to order this 200A ring type underground meter breaker?
Order Eaton B-Line model U2M2R F. That number covers the 200 A, single position, ring type, 3R, underground, flush mount meter breaker with the 200 A 2-pole main in ANSI 61 gray.
How fast can I get the B-LINE U2M2R F delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the B-LINE U2M2R F come with a warranty?
Absolutely. The B-LINE U2M2R F is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the B-LINE U2M2R F?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the B-LINE U2M2R F from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.