B-Line Eaton Series NZM comple...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$7,633.18
Image coming soon

B-Line Eaton Series NZM complete , NZM2-, NZMN2, Thermal-magnetic trip type, Three-pole, 160A, 690 Vac, 750 Vdc, 50 kAIC, Distribution circuit protec

(No reviews yet) Write a Review

Model: NZMN2-A160-NA

In Stock (leaves warehouse same day if ordered before 3pm ET)

$7,633.18
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks
Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMN2, Thermal-magnetic trip type, Three-pole, 160A, 690 Vac, 750 Vdc, 50 kAIC, Distribution circuit protection, Rocker lever, motor drive

NZMN2-A160-NA - spec sheet

Manufacturer Resources

Product Specs

Accessories:
Rocker lever, motor drive
Amperage Rating:
160A
Circuit Breaker Type:
NZMN2
Class:
Distribution circuit protection
Compliances:
Contact Manufacturer
Ean:
4.02E+12
Frame:
NZM2-frame
Interrupt Rating:
50 kAIC
Number Of Poles:
Three-pole
Product Height:
4.5 IN
Product Length Depth:
8.5 IN
Product Weight:
5.4 LB
Product Width:
4.5 IN
Trip Type:
Thermal-magnetic
Voltage Rating:
690 Vac, 750 Vdc
Department:
Electrical
Product Length:
8.5 in

B-LINE NZMN2-A160-NA – Frequently Asked Questions

1) What is the exact model number of the Eaton NZM2 frame 160A three-pole breaker?
The part is NZMN2-A160-NA, an Eaton NZM series molded case circuit breaker on the NZM2 frame. It is a three-pole, 160A thermal-magnetic device rated 690 Vac and 750 Vdc with a 50 kAIC interrupting rating. Order by that full designation, since the NZM2 frame covers a range of amperages and breaking capacities.
2) Can this Eaton NZM2 breaker be used on a DC system as well as AC?
Yes. The NZMN2-A160-NA carries a dual rating of 690 Vac and 750 Vdc, so it can be applied on three-phase distribution up to 690 volts AC and on DC systems up to 750 volts. That DC capability is why NZM frames show up in solar, battery and traction panels as well as standard AC distribution boards.
3) Is a thermal-magnetic trip the right choice, or do I need an electronic trip breaker?
This one is thermal-magnetic, which means a bimetal element handles overload and a magnetic element handles short circuit. That is the standard pick for distribution circuit protection, which is the class this breaker is built for: feeders, sub-panels and general load circuits where you do not need adjustable long-time, short-time or ground-fault settings. If you need selective coordination with downstream devices or field-adjustable curves, an electronic trip unit version of the NZM frame is the better fit.
4) How much space do I need in the panel for this NZM2 breaker?
Plan for a device measuring 8.5 x 4.5 x 4.5 inches and weighing 5.4 lb. Check that footprint against your available panel bay and door cutout before you commit, and account for the motor drive if you are ordering it, since motorized operators add depth on the front of the breaker.
5) Can this breaker be operated remotely for load shedding or a transfer scheme?
Yes. The NZMN2-A160-NA is a complete breaker configured with a rocker lever and motor drive, so it can be opened, closed and reset electrically rather than only by hand at the panel. That is what makes it usable in remote switching, automatic transfer and load management schemes where nobody is standing at the door.
6) Will this 160A breaker protect a 480V three-phase feeder?
It will. With a 690 Vac rating and three poles, the NZMN2-A160-NA covers 208V, 240V, 480V and 600V three-phase distribution, and 160A is the frame's continuous rating. Size the conductors and the load to that 160A, and confirm the fault current at that point is within the breaker's 50 kAIC capacity.
7) Is the NZMN2 a complete breaker or do I have to order the trip unit separately?
It ships as a complete molded case circuit breaker, thermal-magnetic trip included, with the rocker lever and motor drive accessories as configured. You are not assembling a frame and a separate trip unit the way you would with some electronic-trip product lines.
How fast can I get the B-LINE NZMN2-A160-NA delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the B-LINE NZMN2-A160-NA come with a warranty?
Absolutely. The B-LINE NZMN2-A160-NA is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the B-LINE NZMN2-A160-NA?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the B-LINE NZMN2-A160-NA from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.