Bussmann FLJ Maxi Fuse, Time-Delay, Non-Indicating, 32VDC
The Bussmann FLJ Maxi Fuse is an EATON Bussmann Series time-delay fuse rated 32 Vdc with a 1 KAIC interrupt rating, built in a non-indicating, non-illuminating design for straightforward overcurrent protection. This family is available in 45A, 65A, and 75A amp ratings, giving installers a consistent Maxi Fuse platform across a 45A-75A range for DC power distribution and equipment protection circuits. The time-delay characteristic allows the fuse to ride through momentary inrush and transient current spikes without nuisance opening, while still clearing sustained overloads reliably. Whether protecting a single 45A branch circuit or a larger 75A load, the Maxi Fuse form factor keeps replacement and stocking simple across the range.
Key Features
- Amp Rating Range: Available in 45A, 65A, and 75A ratings to match the current demands of the circuit being protected.
- Voltage Rating: Rated 32 Vdc for DC power distribution and low-voltage circuit protection.
- Interrupt Rating: 1 KAIC interrupt capacity for dependable fault clearing under overcurrent conditions.
- Time-Delay Operation: Time-delay design tolerates brief current surges and inrush without opening prematurely.
- Non-Indicating Design: Non-indicating construction keeps the fuse body simple, with no blown-fuse indicator window.
- Non-Illuminating: Non-illuminating housing, with no built-in illumination feature.
- Maxi Fuse Form Factor: Standard Maxi Fuse footprint compatible with common Maxi Fuse holders and blocks.
Technical Specifications
- Packaging Type: Standard
- Fuse Indicator: Non-indicating
Typical Applications
- DC Power Distribution Circuits
- Overcurrent Protection for Electrical Systems
- Industrial and Commercial Equipment Wiring
- Replacement Fuse for Time-Delay Circuit Protection
- Maxi Fuse Holder and Fuse Block Assemblies
Why Bussmann?
Bussmann, part of the EATON Bussmann Series lineup, builds this Maxi Fuse with a clear 32 Vdc, 1 KAIC rating and a time-delay response so electricians and technicians can size protection with confidence. The non-indicating, non-illuminating construction keeps the design straightforward, and the 45A-75A range means the same trusted Maxi Fuse platform scales to fit the circuit at hand. Choose Bussmann for consistent, code-aware overcurrent protection on DC electrical systems and equipment.
Manufacturer Resources
Product Specs
- Packaging Type:
- Standard
- Department:
- Electrical
- Product Group:
- Fuses
- Product Details:
- Time delay, non-illuminating
- Fuse Indicator:
- Non-indicating
- Product Length Depth:
- 1.5625 in
- Product Weight:
- .023 lb
- Voltage Rating:
- 32VDC
- Product Width:
- .625 in
- Product Type:
- Time Delay Fuse
- Product Subgroup:
- Time Delay Fuses
- Interrupt Rating:
- 1 kAIC
- Product Height:
- 1.25 in
- Amperage Rating:
- 45A - 75A