Eaton A200 Overload Heater Coi...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$97.36

Eaton A200 Overload Heater Coil for Size 3 & 4 Starters, 3-Phase

(No reviews yet) Write a Review

Model: FH75

In Stock (leaves warehouse same day if ordered before 3pm ET)

$97.36
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton A200 Overload Heater Coil for Size 3 & 4 Starters, 3-Phase

The Eaton A200 Overload Heater Coil is engineered for use with A200 Starter Sizes 3 and 4 on 3-phase-only applications, providing precise thermal overload protection for motor circuits. This NEMA-design heater is available in a Non-Compensated, Ambient A rating with a full load current range of 23.3-25.6A, and is compatible with Type A and B overload relays featuring both thermal and fast-trip response. Select the correct heater coil based on the full load current (FLA) shown on the motor nameplate to ensure proper protection.

Key Features

  • Amperage Range: Non-Compensated, Ambient A rating of 23.3-25.6A for accurate motor overload sizing.
  • Starter Compatibility: Designed for use with Eaton A200 Starter Sizes 3 and 4, 3-Phase only.
  • Overload Relay Type: Compatible with Type A and Type B overload relays.
  • Trip Type: Thermal and fast trip protection helps guard motors against sustained overcurrent and rapid fault conditions.
  • Design Standard: NEMA design construction for reliable performance in industrial motor control applications.
  • Sizing Guidance: Heater coils are rated to protect at a 40 degree C rise with a 1.15 service factor; three-phase applications require three heaters.

Technical Specifications

  • Warranty: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
  • Product Type: Motor Starter Heater Coil.
  • Design: NEMA.
  • Overload Relay: Type A and B.
  • Type: A200 Heater.
  • Trip Type: Thermal and fast trip.
  • Used With: A200 Starter Sizes 3 & 4, 3-Phase Only.

Typical Applications

  • Motor Control Centers and Starter Panels
  • Three-Phase Motor Overload Protection
  • Industrial and Commercial Motor Starter Retrofits
  • A200 Series Starter Maintenance and Replacement
  • Panelboard and Motor Control Wiring Systems

Why Eaton?

Eaton's A200 overload heater coils are built to NEMA design standards, delivering dependable thermal and fast-trip protection for Size 3 and 4 starters in demanding 3-phase motor control applications. Backed by Eaton's Selling Policy 25-000 warranty, these heater coils help ensure code-compliant, reliable motor protection for professional electrical installations.

Manufacturer Resources

Product Specs

Product Design:
NEMA
Special features:
Used with A200 Starter Sizes 3 & 4, 3-Phase Only
Overload relay:
Type A and B
Product Type:
A200 Heater
Trip type:
Thermal and fast trip
Used with:
Used with A200 Starter Sizes 3 & 4, 3-Phase Only
Department:
Electrical
Amperage Rating:
23.3-25.6A
Standards:
NEMA
Configuration:
Thermal and Fast Trip
Series:
A200
Product Group:
Starters & Contactors

Eaton FH75 – Frequently Asked Questions

1) How do I pick the right Eaton A200 heater coil for my motor?
Size the heater to the full load amps stamped on the motor nameplate, not to the starter size. The Eaton A200 heater coils cover motor FLA bands from 25.3-27.8A (FH75) through 67-73A (FH85), with steps at 27.9-30.6A (FH76), 30.7-33.5A (FH77), 33.6-37.5A (FH78), 37.6-41.5A (FH79), 46.4-50A (FH81) and 62-66A (FH84). Find the band your nameplate FLA falls inside and order that part number.
2) How many heater coils do I need for a three-phase motor starter?
Three. The A200 heater coils are for 3-phase applications only, and a three-phase circuit takes one heater per phase, so order three of the same part number for a single starter.
3) Will these heaters fit an Eaton A200 Size 1 or 2 starter?
No. These FH-series heater coils are built for A200 starter Sizes 3 and 4 only. A Size 1 or Size 2 starter uses a different heater group, so a Size 3/4 heater will not give correct protection even if the amp band looks right.
4) Are these heaters compatible with Type A and Type B overload relays?
Yes, the A200 heater coils work with both Type A and Type B overload relays, and they provide thermal plus fast-trip response in either.
5) What service factor and temperature rise are Eaton A200 heater coils rated to protect at?
The heater coil amp bands are based on protection at a 40 degree C rise with a 1.15 service factor motor. If your motor has a 1.0 service factor or a different rise, the trip point relative to nameplate FLA changes and the heater selection needs to be adjusted accordingly.
6) Is this a compensated or non-compensated heater, and does ambient temperature matter?
These are non-compensated, Ambient A rated heaters. Non-compensated means the trip point shifts with the temperature around the relay, so if the starter enclosure runs much hotter or colder than the motor's ambient, expect the relay to trip earlier or later than the nameplate band suggests.
7) My existing Eaton A200 starter overload keeps tripping. Can I just replace the heater coils?
Yes, heater coils are the replaceable sizing element in an A200 overload relay and are commonly swapped during starter maintenance and retrofits. Before changing size, confirm the motor nameplate FLA against the band on the installed heater. If the heater matches the motor, nuisance tripping usually points at the load, wiring, or the relay itself rather than the coil.
8) Are Eaton A200 heater coils NEMA or IEC design?
NEMA design. The A200 line is NEMA-rated motor control, so these heaters drop into NEMA-style starters and motor control centers, not IEC contactor overload blocks.
9) What is the largest motor FLA these A200 heater coils cover?
The top listed band in this FH group reaches 67-73A with part number FH85. For motors drawing more than that, you need a larger heater from the A200 range and a starter size that supports it.
How fast can I get the Eaton FH75 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton FH75 come with a warranty?
Absolutely. The Eaton FH75 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton FH75?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton FH75 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.