Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On

(No reviews yet) Write a Review

Model: BRP120AF

In Stock (leaves warehouse same day if ordered before 3pm ET)

$76.74
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton BR Series AFCI Circuit Breaker 15A/20A Single-Pole 120V 10kAIC Plug-On

Advanced Arc Fault Protection for Residential Applications

The Eaton BR Series AFCI Circuit Breaker delivers reliable arc fault protection with 15A/20A capacity at 120V. This single-pole plug-on breaker features 10kAIC interrupt rating and UL Listed certification, designed specifically for Type BR Loadcenters. The plug-on neutral connection ensures secure installation while accommodating #14-8 AWG Cu/Al wire sizes for versatile residential wiring applications.

Professional Features & Benefits

  • 15A/20A Capacity: Handles standard residential branch circuit loads with reliable overcurrent protection for lighting and receptacle circuits.
  • 10kAIC Interrupt Rating: Provides robust fault current interruption capability suitable for most residential electrical systems.
  • Plug-On Connection: Enables quick, secure installation without additional hardware while ensuring positive electrical contact.
  • Single-Pole Design: Optimizes panel space utilization while providing dedicated protection for 120V branch circuits.
  • UL Listed Certification: Meets rigorous safety standards ensuring code compliance and reliable performance in residential installations.
  • Plug-On Neutral: Simplifies AFCI wiring requirements with integrated neutral connection for proper arc fault detection.
  • #14-8 AWG Compatibility: Accommodates standard residential wire sizes for both copper and aluminum conductors.

Technical Specifications

  • Certifications: UL Listed
  • Connection: Plug-on
  • Interrupt Rating: 10 kAIC
  • Main Circuit Breaker: BR
  • Neutral: Plug-on neutral
  • Number Of Poles: Single-pole
  • Special Features: UL only
  • Used With: Type BR Loadcenters
  • Voltage Rating: 120 V
  • Wire Size: #14-8 AWG Cu/Al

Professional Applications

  • Residential Branch Circuit Protection
  • New Construction Electrical Systems
  • Electrical Panel Upgrades
  • Code Compliance Installations
  • Multi-Family Housing
  • Residential Service Calls
  • Electrical Contractor Projects

Why Choose Eaton Quality?

Eaton BR Series circuit breakers provide dependable electrical protection with UL Listed certification and proven plug-on connection technology. The 10kAIC interrupt rating and compatibility with Type BR Loadcenters ensure reliable performance in residential electrical systems, backed by Eaton's commitment to electrical safety and code compliance.

Manufacturer Resources

Product Specs

Certifications:
UL Listed
Connection:
Plug-on
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
BR
Neutral:
Plug-on neutral
Number Of Poles:
Single-pole
Special Features:
UL only
Used With:
Type BR Loadcenters
Voltage Rating:
120V
Wire Size:
#14-8 AWG Cu/Al
Department:
Electrical
Product Group:
Circuit Breakers
Product Type:
Circuit Breaker
Product Subgroup:
Electrical

Eaton BRP120AF – Frequently Asked Questions

1) Will an Eaton BR AFCI breaker fit my existing panel?
The BR Series AFCI breaker is built for Eaton Type BR loadcenters and plugs onto the bus in that panel. It will not seat correctly in a Cutler-Hammer CH panel or another manufacturer's loadcenter, since the plug-on footprint is BR specific. Check the label inside your panel door: if it says Type BR, this is the right breaker. If it says CH, you need a CH series AFCI instead.
2) What is the difference between the pigtail and plug-on neutral versions of the Eaton BR AFCI?
Two wiring styles, same protection. The pigtail versions (BRN115AF at 15A, BRN120AF at 20A) carry a white neutral wire you land on the panel neutral bar, and they work in any Type BR loadcenter. The plug-on neutral versions (BRP115AF at 15A, BRP120AF at 20A) pick the neutral up off a neutral bus bar built into the panel, so there is no pigtail to route, but the loadcenter has to be a BR panel equipped for plug-on neutral. If you are replacing a breaker in an older BR panel, order the pigtail.
3) Should I put a 15A or a 20A AFCI breaker on this circuit?
Match the breaker to the wire already in the wall, not to the load. The Eaton BR AFCI comes in 15A (BRN115AF, BRP115AF) and 20A (BRN120AF, BRP120AF). A circuit run in #14 conductor takes the 15A; #12 conductor takes the 20A. Going up to a 20A breaker on #14 wire is the classic mistake and it defeats the overcurrent protection.
4) Can I use this Eaton AFCI breaker on a 240V circuit like a dryer or water heater?
No. It is a single-pole breaker rated 120V, so it protects one hot leg on a standard branch circuit. A 240V appliance circuit needs a two-pole breaker. Use this one for the 120V lighting and receptacle circuits where arc fault protection is required.
5) Does the Eaton BR AFCI breaker also give me GFCI protection for a kitchen or bath circuit?
No. This is an arc fault breaker only, not a dual function AFCI/GFCI. Circuits that require ground fault protection for personnel, kitchen counter receptacles, bathrooms, laundry, garages and outdoors, need a GFCI or dual function device instead. Bedroom, living area and general lighting circuits that only call for arc fault protection are what this breaker is for.
6) What do I need to land besides the hot wire when installing an Eaton BR AFCI?
An arc fault breaker needs the circuit neutral routed through it, not to the panel neutral bar. On the pigtail versions the circuit neutral lands on the breaker's neutral terminal and the breaker's white pigtail goes to the neutral bar. On the plug-on neutral versions the circuit neutral lands on the breaker and the breaker picks up panel neutral from the bus itself. Getting the neutral wrong is the usual cause of an AFCI that trips the moment you close it.
7) What wire sizes will the Eaton BR AFCI breaker lug accept?
The load lug takes #14 through #8 AWG, copper or aluminum. That covers standard #14 and #12 branch circuit conductors on 15A and 20A lighting and receptacle circuits, and leaves room if a larger conductor was pulled for a long run and voltage drop.
8) Is the Eaton BR AFCI breaker UL Listed for a code inspection?
UL Listed, and that listing is what an inspector looks for on an arc fault device. For a panel of units being brought up to current arc fault requirements, the BR AFCI is a straight single-pole swap in a Type BR loadcenter, so standardizing a building on one part number is workable.
How fast can I get the Eaton BRP120AF delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton BRP120AF come with a warranty?
Absolutely. The Eaton BRP120AF is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton BRP120AF?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton BRP120AF from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.