Eaton CH Series Three-Pole The...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$509.09

Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip

(No reviews yet) Write a Review

Model: CH370

In Stock (leaves warehouse same day if ordered before 3pm ET)

$509.09
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker 240V 10kAIC Common Trip

Professional three-pole circuit protection for Type CH loadcenters

The Eaton CH Series Three-Pole Thermal Magnetic Circuit Breaker delivers reliable 240V circuit protection with 10kAIC interrupt rating and common trip functionality. Designed specifically for Type CH loadcenters, this three-pole breaker provides comprehensive electrical protection with UL 489 certification for professional installations requiring multi-pole circuit control and safety.

Professional Features & Benefits

  • 240V Rating: Provides reliable voltage protection for standard residential and light commercial applications requiring three-pole circuit control.
  • 10kAIC Interrupt Rating: Delivers robust fault current interruption capability for enhanced electrical system safety and protection.
  • Three-Pole Configuration: Enables simultaneous control and protection of three-phase circuits with coordinated switching action.
  • Common Trip Design: Ensures all three poles trip together for complete circuit isolation and enhanced safety during fault conditions.
  • CH Series Compatibility: Engineered specifically for Type CH loadcenters ensuring proper fit and reliable electrical connections.
  • UL 489 Certification: Meets rigorous safety and performance standards for molded case circuit breakers in commercial applications.
  • Thermal Magnetic Operation: Combines thermal overload and magnetic short-circuit protection for comprehensive circuit safeguarding.

Technical Specifications

  • Certifications: UL 489
  • Circuit Breaker Type: CH
  • Interrupt Rating: 10 kAIC
  • Main Circuit Breaker: CH
  • Number Of Poles: Three-pole
  • Trip Type: Common breaker trip
  • Used With: Type CH Loadcenters
  • Voltage Rating: 240 V - 240 V

Professional Applications

  • Residential electrical panels requiring three-pole circuit protection
  • Light commercial facilities with 240V three-phase equipment
  • Multi-unit properties with coordinated circuit control needs
  • Professional offices requiring reliable electrical distribution
  • Retail establishments with specialized equipment protection
  • Service panels requiring UL 489 certified circuit breakers

Why Choose Eaton Quality?

Eaton circuit breakers deliver proven reliability with UL 489 certification and robust 10kAIC interrupt rating. The CH Series design ensures compatibility with Type CH loadcenters while providing dependable thermal magnetic protection for professional electrical installations requiring three-pole common trip functionality.

Manufacturer Resources

Product Specs

Certifications:
UL 489
Circuit Breaker Type:
CH
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
CH
Number Of Poles:
Three-pole
Trip Type:
Common breaker trip
Used With:
Type CH Loadcenters
Voltage Rating:
240 V - 240 V
Department:
Electrical
Product Group:
Circuit Breakers
Product Type:
Circuit Breaker

Eaton CH370 – Frequently Asked Questions

1) Will an Eaton CH310 three-pole breaker fit a BR or Cutler-Hammer Type BR loadcenter?
No. The CH three-pole breakers are built for Type CH loadcenters only. Type CH and Type BR use different bus and mounting arrangements, so a CH330 or CH350 will not seat correctly in a BR panel. Check the label inside your panel door for the accepted breaker type before ordering.
2) Does a three-pole CH breaker trip all three poles at once?
Yes, it's a common trip design. A fault or overload on any one pole opens all three together, so the load is fully isolated rather than left single-phasing. That matters on three-phase motors, where losing one leg while the other two stay energized can cook the windings.
3) Can I use this breaker on a 208Y/120 three-phase panel?
The voltage rating is 240V, which covers 208Y/120 and 240V three-phase systems since the line-to-line voltage stays at or below the breaker's rating. It is not rated for 480V or 480Y/277 distribution. For those, you need a breaker series rated to that voltage, not a CH.
4) Can I replace a failed three-pole breaker in a CH panel with this one and keep the same amperage?
If the panel is a Type CH loadcenter, yes. Read the part number off the face of the breaker you're pulling and match the last digits: a CH340 is 40 amps, a CH360 is 60. Keeping the same rating is only correct if the original was sized to the conductor and load in the first place, so verify the wire size while the cover is off.
5) What amperages does the Eaton CH three-pole breaker come in?
Ten ratings: 10A (CH310), 15A (CH315), 25A (CH325), 30A (CH330), 35A (CH335), 40A (CH340), 50A (CH350), 60A (CH360), 70A (CH370) and 100A (CH3100). Size to the load and conductor per the circuit design, not to the largest breaker that will fit the space.
6) What does thermal magnetic mean on a CH breaker, and do I need an electronic trip unit instead?
Thermal magnetic means two protection mechanisms in one breaker: a bimetal element that responds to sustained overload with an inverse time delay, and a magnetic element that trips near-instantly on a short circuit. There are no adjustable settings. If your spec calls for adjustable long-time, short-time or ground-fault pickup, that's an electronic trip breaker and a CH is not the right device.
7) I need a three-phase circuit for an RTU in a small retail space. Is this the right breaker?
For 240V or 208V three-phase equipment fed from a Type CH loadcenter, yes. Match the amperage to the unit's nameplate MCA and maximum overcurrent protection, and take three adjacent spaces in the panel. If the RTU nameplate calls for HACR-rated or fuse-only protection, follow the nameplate. It will not serve a 480V rooftop unit.
8) Does the CH3100 work as a main breaker?
The CH series is listed for main breaker duty in Type CH loadcenters as well as branch use. Whether the 100A CH3100 can serve as your main depends on the specific loadcenter's main breaker provisions and bus rating, which are printed on the panel label. Backfed main installations also require a hold-down kit.
How fast can I get the Eaton CH370 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton CH370 come with a warranty?
Absolutely. The Eaton CH370 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton CH370?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton CH370 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.