Eaton Type CH Main Breaker Loa...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$318.18

Eaton Type CH Main Breaker Load Center 100A Single-Phase 120/240V with Copper Bus

(No reviews yet) Write a Review

Model: CHP30B100X5
$318.18

In Stock (leaves warehouse same day if ordered before 3pm ET)

$318.18
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Eaton Type CH Main Breaker Load Center

Professional electrical distribution for residential and commercial applications

The Eaton Type CH Main Breaker Load Center delivers reliable 100A single-phase electrical distribution with professional-grade construction. Featuring a copper bus system and metallic enclosure, this load center provides dependable power distribution for 120/240V applications with overhead feed capability and 10 kAIC interrupt rating for enhanced electrical safety.

Professional Features & Benefits

  • 100A Service Rating: Provides ample capacity for residential and light commercial electrical distribution needs
  • Copper Bus Construction: Ensures superior conductivity and long-term reliability with excellent corrosion resistance
  • Type CH Main Breaker: Integrated main circuit protection with proven Eaton reliability and performance
  • 10 kAIC Interrupt Rating: Delivers robust fault current protection for enhanced electrical system safety
  • Single-Phase 120/240V: Standard residential voltage configuration compatible with most household and commercial loads
  • Metallic Enclosure: Durable construction provides superior protection and professional appearance
  • Overhead Feed Design: Optimized for standard utility service entrance configurations

Technical Specifications

  • Amperage Rating: 100 A
  • Bus Material: Copper
  • Enclosure Material: Metallic
  • Feed Type: Overhead
  • Interrupt Rating: 10 kAIC
  • Main Circuit Breaker: CH
  • Number Of Poles: Single-pole
  • Phase: Single-phase
  • Product Details: Main breaker
  • Product Width: 14.31 in
  • Voltage Rating: 120/240 V
  • Wire Size: #6-1/0 AWG

Professional Applications

  • Residential electrical service entrance panels
  • Small commercial facility power distribution
  • Multi-unit residential properties
  • Professional office electrical systems
  • Retail establishment power distribution
  • Light industrial electrical panels
  • Electrical contractor installations

Why Choose Eaton Quality?

Eaton load centers deliver proven reliability with professional-grade construction featuring copper bus systems and metallic enclosures. The 10 kAIC interrupt rating and Type CH main breaker design ensure dependable electrical protection and distribution performance for demanding applications.

Manufacturer Resources

Product Specs

Amperage Rating:
100 A
Bus Material:
Copper
Enclosure Material:
Metallic
Feed Type:
Overhead
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
CH
Number Of Poles:
Single-pole
Phase:
Single-phase
Product Details:
Main breaker
Product Width:
14.31 in
Voltage Rating:
120/240 V
Wire Size:
#6-1/0 AWG
Department:
Electrical
Product Type:
Load Center
Product Group:
Power Distribution
Product Subgroup:
Panelboards & Load Centers

Eaton CHP30B100X5 – Frequently Asked Questions

1) Will an Eaton Type CH 100A load center take my existing breakers?
Type CH is its own breaker footprint. The main breaker on this 100A loadcenter is a CH type, and the branch spaces are CH spaces, so it takes Eaton CH branch breakers. Eaton's other line, Type BR, is a different width and will not seat in a CH panel. If the breakers you are pulling out of the old panel are BR or another brand, budget for new CH breakers with the panel.
2) Is there an outdoor rated version of the Eaton CH 100A main breaker panel?
Yes, both indoor and outdoor enclosures are built. For a meter-adjacent service on an exterior wall, take an outdoor box; the R suffix box sizes (X/R, X2R, X5R) are the rainproof variants. Enclosure is metallic either way.
3) What size service conductors will land in the main lugs of a 100A Eaton CH panel?
The main breaker terminals accept #6 through 1/0 AWG. That covers the usual 100A service runs, including 1/0 aluminum SER and #4 copper. If your service entrance conductors are larger than 1/0, they will not land here and you need a bigger frame panel.
4) Can I feed an Eaton CH 100A loadcenter from underground service?
Feed type on this one is overhead, so it is set up for a service drop coming in at the top. A panel is fed from the end the enclosure and bus are arranged for, and swapping that on site is not a field change. For an underground lateral coming up from below, order the underfeed configuration instead.
5) Does a 100A Eaton CH panel work as a subpanel off my existing main?
It works as a subpanel. The 120/240V single-phase rating matches a standard residential or light commercial feed, and the integral 100A main breaker serves as the disconnecting means at the subpanel, which is what you want for a detached garage, a shop, or a tenant space in a multi-unit building. Remember to separate the neutral and ground bars when it is used downstream of the service disconnect rather than as the service panel.
6) Copper bus or aluminum bus in an Eaton CH loadcenter, does it matter?
The bus here is copper. It matters most in humid, coastal, or unconditioned spaces where an aluminum bus stack is more prone to oxidation at the breaker stab, and on panels that get loaded heavily and continuously. For a property manager standardizing across a portfolio, copper bus is the spec worth writing into the standard so every panel in the fleet behaves the same.
7) How wide is an Eaton CH 100A load center, will it fit between my studs?
Width is 14.31 inches. That is wider than a 14-1/2 inch clear stud bay at 16 inch on center leaves you once drywall returns are accounted for on a flush mount, so plan on cutting into the framing or surface mounting. Check the rough opening against 14.31 inches before you frame the wall.
8) Main breaker versus main lug loadcenter, which do I need for a service panel?
This is a main breaker unit, with the 100A overcurrent device built into the panel. That is what a service entrance panel needs, because the service requires a disconnecting means and overcurrent protection at the point of entry. A main lug panel has no main breaker and is only correct when it sits downstream of a breaker that already protects the feeder, or where a separate service disconnect is mounted ahead of it.
9) Can I use an Eaton CH 100A single-phase panel on a 208V three-phase building service?
No. This loadcenter is single-phase, 120/240V. On a three-phase service you would be feeding it from two legs of a 120/208V system, and both the phase rating and the voltage rating are wrong for that. For a three-phase distribution you need a three-phase panelboard, not a single-phase loadcenter. It is fine for a single-phase tenant feed pulled off a larger building service.
10) Which box size do I order for an Eaton CH 100A outdoor panel with 30 spaces?
Two things get specified together: the box size and the enclosure. Box sizes offered are X/R, X1, X2, X2R, X5, and X5R, and the R versions are the outdoor ones. Pole capacity tops out at 30. So an outdoor 30 space job takes one of the R boxes at the 30 pole rating. Main breaker type is CH at 10 kAIC across the whole range, so that part is not a choice you have to make.
How fast can I get the Eaton CHP30B100X5 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton CHP30B100X5 come with a warranty?
Absolutely. The Eaton CHP30B100X5 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton CHP30B100X5?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton CHP30B100X5 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.