Hager 2911 6A Modular Access C...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,385.35
$1,137.96

Hager 2911 6A Modular Access Control Power Supply with Field Selectable 12/24VDC Output

(No reviews yet) Write a Review

Model: 2911

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,385.35
$1,137.96
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Hager 2911 6A Modular Access Control Power Supply with Field Selectable 12/24VDC Output

Professional Modular Power Supply for Access Control Systems

The Hager 2911 modular access control power supply delivers up to 6 amps of field-selectable 12 or 24 volt DC power for all Hager electrified products. This UL294 listed power supply features a regulated modular design measuring 16" height, 14" width, and 6.5" depth, constructed with 16 gauge steel housing. The unit operates on 115 VAC, 50/60 Hz input (230 VAC optional) and provides 13.5/27 VDC, 500 mA charging output with fire alarm input capability.

Professional Features & Benefits

  • High-Capacity Power Output: Delivers up to 6 amps at field-selectable 12 or 24 VDC for comprehensive system power requirements.
  • Modular Expandability: Regulated modular design allows complete customization with optional modules including battery backup, relay modules, and power boost capabilities.
  • Advanced Protection Systems: Circuit breaker protected AC input with filtering and output voltage regulation ensures component longevity and system reliability.
  • Fire Safety Integration: Built-in fire alarm input with standard California compliant manual release for emergency applications.
  • Professional Construction: 16 gauge steel housing with high-performance transformer and reliable electronic components for demanding commercial applications.
  • Comprehensive Status Monitoring: LED indicators provide real-time status - amber for normal operation, green for no DC output, red for battery backup mode.
  • Compatible Accessories: Extensive module options available including Part #2-679-0661 battery backup, Part #2-679-0662 12VDC regulator, Part #2-679-0664 universal relay module, and Part #2-679-0705 16 amp power boost module.
  • Manufacturer Warranty: One-year warranty coverage for added confidence and protection.
  • Fire alarm input

Technical Specifications

  • Accessories: 2-679-0661 - 5 Amp hour battery backup
  • Ampheres: 6 Amps
  • ANSI/BHMA: UL294 Listed
  • Applications: Provides up to 6 amp of 12 or 24 volt DC power for all electrified products
  • Commercial/Residential: Commercial
  • Electrical Specifications: 1.2A @ 115 VAC, 50/60 Hz (230 VAC optional)
  • Features: Fire alarm input
  • Gauge: 16 Gauge Steel
  • LED Indicators: Amber - AC and DC voltages are OK
  • Size: 16" Height, 14" Width, 6.5" Depth
  • Subcategory: Modular Power Supplies
  • Voltage: 12/24VDC Field Selectable
  • Warranty: One-year

Installation & Operation

  1. Verify electrical requirements match available power supply. Confirm 115 VAC, 50/60 Hz input capacity and ensure adequate space for 16" x 14" x 6.5" unit dimensions.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Mount the unit in the specified location ensuring adequate clearance for wiring access, ventilation, and future service requirements.
  4. Route and connect wiring according to manufacturer wiring diagrams. Configure field-selectable voltage output for 12 or 24 VDC per application requirements.
  5. Configure operational settings including fire alarm input connections and any installed optional modules per application requirements.
  6. Restore power and test all functions including normal operation, LED status indicators, and integration with connected electrified hardware systems.
  7. Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.

Professional Applications

  • Commercial Building Access Control Systems
  • Electric Lock and Strike Power Distribution
  • Magnetic Lock System Power Supply
  • Delayed Egress Device Power Management
  • Magnetic Hold Open Device Systems
  • Multi-Door Access Control Installations
  • Fire Safety Integration Applications

Why Choose Hager Quality?

Hager 2911 power supplies deliver professional-grade reliability with 16 gauge steel construction and high-performance transformer components rated for demanding commercial applications. UL294 listing ensures compliance with industry safety standards, while the one-year warranty provides added confidence. Engineered with advanced filtering and voltage regulation to protect and extend the life of all connected system components.

Electric strike for fail-safe or fail-secure access control applications. Compatible with cylindrical, mortise, and exit device trim.

Product Specs

Subcategory:
Modular Power Supplies
ANSI/BHMA:
UL294 Listed
Product Group:
Electronic Access Controls
Product Subgroup:
Power Supplies
Product Type:
Modular Power Supplies
Commercial/Residential:
Commercial
Ampheres:
6 Amps
Product Model:
2911
Product Voltage:
12/24 VDC
Product Category:
Power Supplies
Department:
Door Hardware

Hager 2911 – Frequently Asked Questions

1) Will the Hager 2911 power supply run both 12V and 24V devices, or do I have to pick one when I order?
You pick the voltage in the field, not on the order form. The 2911 has a field-selectable 12 or 24 VDC output, so one part number covers either. What it will not do is put out both at once from the base unit, the selection sets the whole output. If you have a mixed 12V and 24V opening list on the same job, plan on a second supply or add the 12VDC regulator module, Part #2-679-0662, to derive 12V alongside a 24V board.
2) How many maglocks or electric strikes can one Hager 2911 6 amp power supply run?
The 2911 delivers up to 6 amps total at whichever voltage you select, and that is the number to budget against. Add the holding current of every device on the board, strikes, maglocks, delayed egress devices, mag hold-opens, then leave headroom for inrush on strikes that spike when they fire. Six amps is a multi-door supply, not a single-opening one. If the load list comes out over 6 amps, the 16 amp power boost module, Part #2-679-0705, is the way up rather than a second cabinet.
3) Does the Hager 2911 power supply drop power to maglocks on a fire alarm signal?
Yes, it has a fire alarm input built in, so a signal from the FACP kills DC output to release fail-safe locks. It also ships with a California compliant manual release as standard. That combination is what an AHJ looks for on a maglock or delayed egress installation, where the hardware has to release on alarm and on a local pull.
4) Does the Hager 2911 come with battery backup, or is that a separate part?
Battery backup is a module you add, not something in the box. The backup module is Part #2-679-0661, a 5 amp hour battery backup. The base 2911 is a modular chassis, so battery backup, relay modules and power boost all get specified separately. Order the modules with the supply if the job needs standby power, they are the same conversation as the supply itself.
5) How much wall space do I need to mount a Hager 2911 power supply enclosure?
The cabinet measures 16 inches height, 14 inches width, 6.5 inches depth, in 16 gauge steel. Lay out for more than the footprint, though. You need clearance in front for wiring access and service, and around it for ventilation, plus room to swing the door. In a tight electrical closet the 6.5 inch depth is usually the number that bites, not the height.
6) What input power does the Hager 2911 need at the panel?
It draws 1.2A at 115 VAC, 50/60 Hz, so a standard dedicated 120V circuit covers it. A 230 VAC version is available as an option for international or 230V service. The AC input is circuit breaker protected with filtering, and the output side is regulated.
7) What modules can be added to a Hager 2911 modular power supply?
Four accessory modules are listed for the 2911: Part #2-679-0661 for 5 amp hour battery backup, Part #2-679-0662 for a 12VDC regulator, Part #2-679-0664 universal relay module, and Part #2-679-0705 for a 16 amp power boost. The relay module is the one integrators reach for when a card reader or REX has to switch the lock output. The regulator is how you get a 12V leg off a 24V board.
8) Is a modular power supply like the Hager 2911 overkill for a single door, or should I use a plug-in transformer?
For one strike on one door, a 6 amp modular cabinet is more supply than the opening needs. Where the 2911 earns its place is a multi-door install, or any opening where the lock has to drop on a fire alarm signal, because the fire alarm input and California compliant manual release are built into the unit rather than bolted on afterward. It is also the right call when you expect to add doors, since the chassis takes battery backup, relay and power boost modules later without replacing the supply.
9) What do the LED colors mean on a Hager 2911 power supply?
Amber means AC and DC voltages are OK, normal running state. Green means there is no DC output. Red means the unit is running on battery backup. So a red light on a walkthrough is not a failure, it is telling you the AC side has dropped and the battery module is carrying the load, which is the first thing to check before pulling the cabinet apart.
10) What does the 13.5/27 VDC charging output on the Hager 2911 mean?
That is the battery charging rail, 13.5 or 27 VDC at 500 mA depending on which output voltage you have selected. It floats the standby battery in the backup module rather than powering locks, so it is not part of your 6 amp lock budget. The 500 mA figure is what sets how long a discharged battery takes to come back up after an outage.
How fast can I get the Hager 2911 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Hager 2911 come with a warranty?
Absolutely. The Hager 2911 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Hager 2911?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Hager 2911 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.