Leviton Provolt™ PIR Occupancy...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$240.98

Leviton Provolt™ PIR Occupancy Sensor, 2-Pole, 120-277V

(No reviews yet) Write a Review

Model: ODC15-IDW

In Stock (leaves warehouse same day if ordered before 3pm ET)

$240.98
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Leviton Provolt™ PIR Occupancy Sensor, 2-Pole Line Voltage, 120-277V

The Leviton Provolt™ Occupancy Sensor is a 2-Pole, line voltage lighting control designed for 8'-12' ceiling mount installations, using PIR sensor technology with daylighting and auto-calibration to cover up to 1500 sq ft. Operating on 120-277V AC/CA at 50/60Hz, this White-finish sensor is UL/CE listed and RoHS, CEC Title 20/24 compliant, making it well suited for energy-code-driven commercial retrofits and new construction lighting control projects.

Key Features

  • 2-Pole Line Voltage Control: Directly switches line voltage loads without a separate power pack, simplifying installation in commercial spaces.
  • PIR Sensor with Daylighting: Passive infrared detection combined with daylighting logic automatically adjusts lighting based on occupancy and available ambient light.
  • Auto-Calibration: Self-adjusting sensitivity reduces commissioning time and improves detection accuracy over the coverage area.
  • Ceiling Mount Range: Engineered for 8'-12' ceiling mount heights, matching typical commercial ceiling installations.
  • 1500 Sq Ft Coverage: Rated to cover up to 1500 square feet from a single sensor location.
  • Universal Voltage: Operates on 120-277V AC/CA, 50/60Hz, for flexible use across commercial electrical systems.
  • Finish: Available in White to blend with standard ceiling installations.

Certifications & Compliance

  • UL Listed
  • CE Certified
  • RoHS Compliant
  • CEC Title 20/24 Compliant

Technical Specifications

  • Poles: 2-Pole
  • Voltage: 120-277V AC/CA, 50/60Hz
  • Coverage Area: 1500 sq ft
  • Mounting Height: 8'-12' Ceiling Mount
  • Sensor Type: PIR with Daylighting and Auto-Calibration
  • Color: White
  • Available Models: O2C15-IDW, ODC15-IDW
  • list_batch: LEV-PREEXIST-20260803

Typical Applications

  • Commercial Office Lighting Control
  • Classrooms and Educational Facilities
  • Open-Plan and Common Areas
  • Energy Code Compliant Retrofits
  • New Construction Lighting Projects

Why Leviton?

Leviton's Provolt™ occupancy sensors combine PIR detection, daylighting, and auto-calibration to deliver reliable, code-compliant lighting control for commercial buildings. Backed by UL/CE listing and RoHS and CEC Title 20/24 compliance, this 2-Pole line voltage sensor is built to help facilities meet energy codes while simplifying installation and commissioning.

Manufacturer Resources

Product Specs

Product Type:
Occupancy Sensor
Listing:
UL Listed, CE
Department:
Electrical
Product Group:
Wiring Devices
Sensor Type:
Ceiling Mount
Country of Origin:
China
Coverage:
1500 square feet
Frequency:
50/60 hertz
Product Subgroup:
Switches

Leviton ODC15-IDW – Frequently Asked Questions

1) Does the Leviton Provolt ceiling occupancy sensor need a separate power pack?
No. The Provolt O2C15-IDW is a 2-pole line voltage sensor, so it switches the line voltage load directly at the sensor. That removes the separate power pack and low voltage run a 24V ceiling sensor requires. It runs on 120-277V AC at 50/60 Hz, so the same part works on a 120V office circuit or a 277V commercial lighting branch.
2) Will a PIR occupancy sensor work in a restroom or a space with partitions?
Passive infrared needs line of sight to moving body heat, so partitions, stall walls, and tall furniture block detection. The Provolt is PIR only. Where occupants sit still or are hidden behind obstructions, an ultrasonic or dual technology head is the better call, such as the Pass and Seymour UT3053 Wattstopper ultrasonic ceiling sensor (2000 sq ft, 360 degrees) or the DT300 Wattstopper dual technology ceiling sensor. Both of those are 24V, so they need a power pack the Provolt does not.
3) Does this Leviton sensor meet California Title 24 for lighting control?
The Provolt sensor is listed as CEC Title 20/24 compliant, UL Listed, CE certified, and RoHS compliant. It includes daylighting, which is the ambient light response energy codes ask for on daylit zones, and auto-calibration so the sensitivity self-adjusts rather than being dialed in by hand at commissioning.
4) The room has partitions and low-motion desk work where PIR keeps dropping out - what is a better sensor than the Leviton Provolt PIR?
In spaces where occupants sit still or line of sight is broken by partitions, a dual technology head handles it better than PIR alone. The Pass & Seymour DT300 Wattstopper is a dual technology ceiling occupancy sensor, 24V, with 360 degree coverage. The Leviton Provolt O2C15-IDW is passive infrared only, with daylighting and auto-calibration, rated to 1500 square feet. The DT300 is a 24V device wired through a power pack, while the Provolt is a 2-pole line voltage sensor at 120-277V that switches the load directly.
5) Can I swap a Wattstopper DT300 or UT3053 into the same wiring as a Leviton Provolt O2C15-IDW?
No - these are not drop-in swaps at the wiring. The Pass & Seymour DT300 and UT3053 Wattstopper ceiling sensors are 24V devices, which means the sensor runs on low voltage and a separate power pack switches the load. The Leviton Provolt O2C15-IDW is a 2-pole line voltage sensor running 120-277V AC at 50/60 Hz and switches the load without a separate power pack. Going from the Provolt to either Wattstopper means adding a power pack and low-voltage run; going the other direction means the existing power pack is no longer needed.
6) I need a ceiling PIR sensor for about a 1200 square foot open area. What are my options?
The Leviton Provolt covers up to 1500 sq ft and switches line voltage on its own. If you want a lower profile head and are already running a 24V control system, the Pass and Seymour CI305 Wattstopper low-profile ceiling PIR covers 360 degrees at 1200 sq ft. Both are PIR, so the same line of sight limits apply to each.
7) Can I use one Leviton Provolt sensor to control two separate lighting circuits?
Yes, that is what the 2-pole configuration is for. It gives you two switched line voltage poles from one sensor, which is how you drive two loads or two zones, for example a daylit row near the windows and the interior row, off a single ceiling head. Keep both poles within the 120-277V range.
8) Which ceiling occupancy sensor should I specify for a Title 24 project with daylight harvesting?
The Leviton Provolt O2C15-IDW pairs PIR detection with daylighting logic and auto-calibration, and is UL Listed and CE, RoHS and CEC Title 20/24 compliant, covering up to 1500 square feet from an 8 to 12 foot ceiling. Among ceiling alternatives, the Pass & Seymour CI305 Wattstopper is a low-profile PIR head rated 1200 sq ft, the DT300 is dual technology at 24V, and the UT3053 is ultrasonic at 2000 sq ft - all three are occupancy detection heads. If the daylight response has to come from the ceiling sensor itself, the Provolt is the one carrying daylighting in the same device.
9) Does the Leviton Provolt sensor come in any color other than white?
White only. On a white acoustic tile or painted gypsum ceiling it disappears well enough; on a dark or exposed structure ceiling it will read as a visible white disc, so plan for that in finish sensitive spaces.
10) Do I have to set sensitivity on the Leviton Provolt at startup?
Auto-calibration handles it. The sensor self-adjusts sensitivity over the coverage area instead of requiring a tech on a ladder tuning pots room by room, which is the main labor saving on a multi-room retrofit. Daylighting logic is built in as well, so ambient light response does not need a separate photocell.
11) What is the difference between the Leviton O2C15-IDW and ODC15-IDW?
Both are Leviton Provolt ceiling mount PIR occupancy sensors in White, 2-pole line voltage at 120-277V, 50/60 Hz, with daylighting and auto-calibration and 1500 square feet of coverage from an 8 to 12 foot ceiling. They are separate Leviton model numbers - O2C15-IDW carries UPC 078477642658 and ODC15-IDW carries UPC 078477642986 - so order by the exact model your drawing or existing device calls out rather than treating the two as interchangeable line items.
How fast can I get the Leviton ODC15-IDW delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Leviton ODC15-IDW come with a warranty?
Absolutely. The Leviton ODC15-IDW is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Leviton ODC15-IDW?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Leviton ODC15-IDW from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.