RCI VR166 Vertical Rod Electri...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$442.00
$288.51

RCI VR166 Vertical Rod Electric Strike for Concealed Exit Devices with Fail Secure Operation

(No reviews yet) Write a Review

Model: VR166 32D

In Stock (leaves warehouse same day if ordered before 3pm ET)

$442.00
$288.51
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

RCI VR166 Vertical Rod Electric Strike for Concealed Exit Devices with Fail Secure Operation

Compact Electric Strike Solution for Vertical Rod Exit Device Applications

The RCI VR166 is a small footprint vertical rod electric strike designed for single or double-door applications with concealed vertical rod exit devices. This solenoid-activated strike operates on 12/24VDC or 12-24VAC with fail secure operation and features a compact 104 mm x 50 mm x 16 mm total footprint. The simple design requires only a 63 mm x 33 mm cut-out in the frame and provides 8 mm horizontal adjustability for frame and door variations. Constructed in satin stainless steel finish with UL294 and UL1034 listings for professional access control applications.

Professional Features & Benefits

  • Compact Footprint Design: Total dimensions of 104 mm x 50 mm x 16 mm with simple 63 mm x 33 mm frame cut-out for minimal installation impact.
  • Flexible Power Options: Operates on 12/24VDC or 12-24VAC for compatibility with various access control systems and power supplies.
  • Fail Secure Operation: Provides secure locking when power is removed, ensuring controlled access during power outages or system failures.
  • Installation Adjustability: 8 mm horizontal adjustment accommodates frame and door variations for precise alignment and optimal performance.
  • Solenoid Activation: Reliable solenoid-activated mechanism designed for minimum 52 mm (2 1/16") backset of the top latch for proper engagement.
  • Dual Application Capability: Suitable for both single and double-door installations with concealed vertical rod exit devices.
  • Professional Grade Certifications: UL294 Listed for Access Control Unit Accessory and UL1034 burglary-resistant Listed with ANSI/BHMA A156.31 Grade 1 certification.
  • Durable Construction: Satin stainless steel finish provides corrosion resistance and professional appearance for commercial applications.

Technical Specifications

  • Commercial/Residential: Commercial
  • Compatibilty: Concealed Vertical Rod Exit Devices
  • Department: Door Hardware
  • Electronic: Yes
  • Lock Type: Exit Device
  • Product Category: Electronic Access Controls
  • Product Finish: Satin Stainless Steel
  • Product Group: Electronic Access Controls
  • Product Subgroup: Electric Strikes
  • Product Type: Vertical Rod Electric Strike
  • Product Voltage: 12/24 VAC/DC
  • Subcategory: Electric Strikes
  • UL Listing Type: UL 294 Listed, UL 1034 Burglary-Resistant Listed, Certified to ANSI/BHMA Standard A156.31, Grade 1

Installation & Operation

  1. Verify electrical requirements match available power supply. Confirm 12/24VDC or 12-24VAC voltage and current capacity before proceeding.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Cut frame opening to 63 mm x 33 mm dimensions and mount the unit ensuring the total footprint does not exceed 104 mm x 50 mm x 16 mm clearance requirements.
  4. Route and connect wiring according to manufacturer wiring diagrams. Use appropriate wire gauge and connectors for the application.
  5. Configure fail secure operation settings and adjust horizontal positioning up to 8 mm to accommodate frame and door variations for proper latch engagement.
  6. Restore power and test all functions including normal operation, fail secure locking, and integration with connected access control systems.
  7. Complete final inspection ensuring minimum 52 mm (2 1/16") backset clearance for top latch operation. Refer to manufacturer documentation for complete wiring diagrams and troubleshooting.

Professional Applications

  • Commercial Building Security Systems
  • Educational Institution Access Control
  • Healthcare Facility Controlled Entry
  • Government and Municipal Buildings
  • Industrial Facility Security
  • Multi-Tenant Residential Properties
  • Retail Loss Prevention Systems

Why Choose RCI Quality?

RCI vertical rod electric strikes deliver professional-grade reliability with solenoid-activated operation and compact design engineered for demanding commercial access control applications. UL294 and UL1034 listings with ANSI/BHMA A156.31 Grade 1 certification ensure compliance with industry standards for burglary resistance and access control performance. The satin stainless steel construction and adjustable mounting design provide dependable operation where precise access control is essential.

Manufacturer Resources

Product Specs

Product Group:
Electronic Access Controls
Product Subgroup:
Electric Strikes
Product Type:
Vertical Rod Electric Strike
Electronic:
Yes
UL Listing Type:
UL 294 Listed, UL 1034 Burglary-Resistant Listed, Certified to ANSI/BHMA Standard A156.31, Grade 1
Subcategory:
Electric Strikes
Commercial/Residential:
Commercial
Compatibility:
Concealed Vertical Rod Exit Devices
Lock Type:
Exit Device
Product Voltage:
12/24 VAC/DC
Product Finish:
Satin Stainless Steel
Product Category:
Electronic Access Controls
Department:
Door Hardware

RCI VR166 32D – Frequently Asked Questions

1) Will the RCI VR166 electric strike work with a concealed vertical rod exit device?
That is exactly what the VR166 is built for. It releases the top latch of concealed vertical rod exit devices on single or double doors, and it needs a minimum 52 mm (2 1/16 inch) backset at that top latch to engage properly. If your exit device is a surface vertical rod or a rim device, this is the wrong strike for it.
2) How big a cut-out does the RCI VR166 vertical rod strike need in the frame head?
The frame prep is a 63 mm x 33 mm cut-out, and the body occupies 104 mm x 50 mm x 16 mm overall, so plan clearance to those dimensions behind the head. It is a small-footprint unit, which is the point of it on a header where there is already rod hardware.
3) What happens to the door if power drops on an RCI VR166 strike?
Fail secure. Cut the power and the VR166 stays locked, so the opening holds security through an outage. Egress is still there because the exit device itself always retracts the rods mechanically from the inside. If your opening needs to release on power loss, specify a fail safe device instead.
4) Is the RCI VR166 strike UL listed and what grade is it?
UL 294 Listed as an access control unit accessory and UL 1034 Burglary-Resistant Listed, and certified to ANSI/BHMA A156.31 Grade 1. That combination is what a specification for a school, hospital, or government opening usually calls for on an electrified vertical rod application.
5) What is the difference between the standard RCI VR166 and the latch and keeper monitor version?
Two ways to order it. Standard gives you the release function only. The latch and keeper monitor option adds monitoring so the access control head end can see latch and keeper status, which is what you want when the door is tied into an alarm or has to report a held-open or unsecured condition. Pick the monitored version at order time; it is not something you add to the standard unit later.
6) What voltage does the RCI VR166 electric strike run on?
12/24 VDC or 12-24 VAC, solenoid activated, so it drops onto most access control power supplies without a separate transformer. Confirm your supply has the current capacity before you commit the run.
7) How much alignment adjustment does the RCI VR166 give you if the frame and door are out of true?
8 mm of horizontal adjustment. On a pair of doors with concealed rods, top latch alignment is usually the fight, and that range covers normal frame and door variation without re-cutting the header prep.
8) Will an RCI VR166 strike match the other stainless door hardware in a commercial building?
It comes in satin stainless steel, which is the common commercial finish, and it is a commercial-duty product rather than a residential one. Mounted in the frame head, only a small face is visible anyway on a 104 mm x 50 mm body.
How fast can I get the RCI VR166 32D delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the RCI VR166 32D come with a warranty?
Absolutely. The RCI VR166 32D is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the RCI VR166 32D?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the RCI VR166 32D from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.