Schlage L9080R02A Storeroom Mo...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,431.00
$882.65

Schlage L9080R02A Storeroom Mortise Lock with Large Format IC Core C Keyway

(No reviews yet) Write a Review

Model: L9080R02A626
Selected Finish is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,431.00
$882.65
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Schlage L9080R02A Storeroom Mortise Lock with Large Format IC Core C Keyway

For more than 90 years, Schlage has been creating the strongest and most technologically advanced security products for homes, multi-family, commercial, and institutional buildings. We have been meticulous designers, painstaking engineers, and proud craftsmen. From durable mechanical locks to comprehensive electronic access control solutions and biometrics, Schlage provides protection at critical moments–when property and personal security are at stake. In homes, public buildings, and the workplace, at the end of the day, Schlage stands for one thing: strong.

  • Storeroom - Latchbolt Retracted by Key Outside or by Knob/Lever Inside, Outside Knob/Lever Always Inoperative, Auxiliary Latch Deadlocks Latchbolt When Door is Locked, Inside Knob/Lever is Always Free for Immediate Egress
  • ANSI/BHMI Certified A156.13-2012
  • Commercial Grade 1
  • Lock Body Mortises Inside the Edge of the Door
  • UL Listed for 3 Hour Fide Door

 

Product Overview

  • Category: Mechanical Commercial Locksets

  • Subcategory: Mortise Locksets

  • Series: L Series

  • Function: Storeroom

  • Handing: Reversible

  • Fire Rated: Yes (UL Listed for 3-Hour Fire Door)

Dimensions & Door Specs

  • Backset: 2-3/4"

  • Door Thickness: 1-3/4"

  • Door Range: 1-3/4"

  • Lever Dimensions: 4-3/4" Length with 2-13/16" Projection

  • Rose Dimensions: 2-1/8" Diameter

  • Latch Faceplate: 1-1/4" x 8"

  • Strike Dimensions: 4-7/8" x 1-1/4" Lip (ANSI Strike)

Trim & Finish

  • Lever/Knob Design: 02 Lever

  • Rose/Escutcheon Design: A Rose

  • Material: Zinc Base

  • Finish: Satin Chrome

  • Finish Code: 626

Keying & Security

  • Keyway: C Keyway

  • Cylinder Type: 6 Pin Cylinder

Warranty & Logistics

  • Warranty: Limited 10-Year Mechanical / 3-Year Electro-Mechanical

  • Order Qty: 1

  • No. of Inners: 1

  • Hazardous Material: No

Manufacturer Resources

Product Specs

Series:
HL6 Series
Product Category:
Mechanical Locks
Duty Level:
Heavy Duty
Handle Type:
Lever
Keyed Function:
Single Cylinder
Standard Strike:
ASA strike, ANSI 115.1 (1-1/4" x 4-7/8")
Keyed:
Yes
Subcategory:
Hospital Latches
ANSI/BHMA:
F07
Product Group:
Mechanical Locks
Product Subgroup:
Mortise Locks and Trim
Product Type:
Hospital Latches
Electronic:
No
Product Substrate:
Zinc and Steel
Commercial/Residential:
Commercial
Lock Type:
Mortise
Lock Function:
Storeroom
Product Model:
L9080R02A
Product Function:
Storeroom
Door Hand Direction:
Non-Handed
Door Thickness Range:
1-3/4"
Backset (Distance):
2-3/4"
Department:
Door Hardware

Schlage L9080R02A626 – Frequently Asked Questions

1) Will the Schlage L9080R02A mortise lock fit a 1-3/4 inch commercial door?
Yes, and only that thickness. The L9080R02A is built for 1-3/4 inch doors with a 2-3/4 inch backset, which is the standard commercial mortise prep. If your door is thinner or thicker, this is the wrong body.
2) What does the storeroom function actually do on this Schlage mortise lock?
Outside lever is always inoperative, so the door is always locked from the corridor side and the key retracts the latchbolt. Inside lever is always free for immediate egress, and an auxiliary latch deadlocks the latchbolt when the door is closed. That is ANSI/BHMA function F07. Good for mechanical rooms, supply rooms, and any opening that must never be left unlocked by a user.
3) Do I need to order this Schlage L9080 lock left hand or right hand?
No handing to specify. The L9080R02A is non-handed and reversible, so one part covers either swing on the job.
4) Can I use this lock on a 3-hour fire rated door?
Yes. The L9080R02A is UL Listed for a 3-hour fire door, and it's ANSI/BHMA A156.13-2012 certified Grade 1 for commercial heavy duty use.
5) Will this Schlage mortise lock work with my existing ANSI strike in the frame?
It ships against a standard ASA strike to ANSI 115.1, 1-1/4 inch by 4-7/8 inch with a 1-1/4 inch lip, and the latch faceplate is 1-1/4 by 8 inches. If your frame is already prepped for ASA/ANSI 115.1, the lock drops into the existing strike cutout.
6) Does the Schlage L9080R02A take my existing Schlage C keyway cores?
It is keyed to the Schlage C keyway with a 6-pin cylinder, single cylinder keyed function, and accepts a large format interchangeable core. If your building is already keyed in Schlage C with LFIC, it can go straight into your existing masterkey system.
7) What is the closest mortise hospital push/pull latch to the Schlage L9080R02A if I need a different brand?
The ABH 6600 Series is the nearest match in construction: it is a mortise lock hospital push/pull latch with a 2-3/4 inch backset, the same backset the Schlage L9080R02A uses. The difference to plan for is function and keying - the Schlage L9080R02A is a keyed storeroom lock, single cylinder, so the outside trim stays inoperative until a key retracts the latchbolt, while the ABH 6600 is described simply as a mortise hospital push/pull latch. If the opening has to lock, confirm the ABH is ordered in a keyed configuration before substituting.
8) I do not need the opening to lock - what push/pull latch should I use instead of the Schlage L9080R02A?
For an unlocked opening, the Trimco 1562A Hospital Series push/pull latch is the straightforward alternative: it is a passage function, levers-down tubular latch rated heavy duty. The Schlage L9080R02A is a keyed storeroom mortise lock, so it carries a cylinder and mortise lock body you would not be using on a passage door. Note the Trimco is tubular rather than mortise, so the door prep is different from the mortise pocket and 1-1/4 inch by 8 inch faceplate the Schlage requires.
9) What trim and finish does the L9080R02A come with?
02 lever on an A rose, zinc base with a satin chrome 626 finish. The lever measures 4-3/4 inches long with a 2-13/16 inch projection and the rose is 2-1/8 inches in diameter, so it matches other 626 lever trim on adjacent openings. Satin chrome 626 is the only finish offered.
10) Should I use a keyed mortise lock or a hospital push/pull latch on a patient room door?
Different jobs. The L9080 with an 02 lever is a keyed storeroom lock, right when the door must stay secured and open by key only. A hospital push/pull latch opens with a forearm or a cart and is normally passage rather than keyed. If that is what the opening needs, look at the ABH 6000 Series push/pull hospital latch, the low profile ABH 6800, or the Trimco 1562A tubular passage push/pull latch with levers down.
11) Is there a push/pull hospital latch that matches this lock's 2-3/4 inch backset mortise prep?
The ABH 6600 Series is a mortise lock hospital push/pull latch built to a 2-3/4 inch backset, the same backset as the Schlage L9080R02A. If you want quieter operation in a low profile body, ABH also lists the 6800Q with a round cover.
12) Is this an electrified lock, and does it hold its function if power drops?
Purely mechanical. The L9080R02A has no electrified option, so nothing changes when power fails: outside stays locked, inside lever stays free to exit. If you need access control at the opening, this body is not the one to specify.
13) Is the door prep for this mortise lock different from a cylindrical lockset?
Yes. The lock body mortises into the edge of the door rather than sitting in a cross bore, so a door prepped for a cylindrical lever cannot take it without new prep. Budget for a mortise pocket plus the 1-1/4 by 8 inch faceplate cutout on the edge.
14) Is there a lower profile hospital latch than the Schlage L9080R02A for a tight corridor?
Yes. The ABH 6800 Series is a low profile hospital push/pull latch with ADA compliance, and the ABH 6800Q is the quiet version of that low profile body with a round cover. The Schlage L9080R02A uses lever trim with a 4-3/4 inch lever length and 2-13/16 inch projection on a 2-1/8 inch rose, so it stands further off the door face than the ABH low profile units. Keep in mind the Schlage is a keyed storeroom mortise lock, which is a different function class from a push/pull latch body.
15) Does the Kaba Ilco 459 paddle replace the Schlage L9080R02A?
No - they solve different problems. The Kaba Ilco 459 Series is a push/pull paddle, meaning trim that operates a latch, while the Schlage L9080R02A is a complete Grade 1 mortise lock body with lever trim, a 6-pin C keyway cylinder and a storeroom function that deadlocks the latchbolt through an auxiliary latch. Specifying the 459 paddle on a door that needs the storeroom lock leaves you without the lock body and cylinder.
16) Is this lock durable enough for high traffic commercial openings?
It's rated Commercial Grade 1 heavy duty under ANSI/BHMA A156.13-2012, with a zinc and steel build. That is the top commercial grade, which is what schools, hospitals, and institutional corridors typically specify.
17) I need a quieter latch on a patient room door - what are my options versus the Schlage L9080R02A?
The ABH 6800Q is the quiet version in the low profile hospital push/pull family, with a round cover. The Schlage L9080R02A is a standard mortise storeroom lock with a 2-3/4 inch backset, ASA/ANSI 115.1 strike prep at 1-1/4 inch by 4-7/8 inch, and lever trim rather than a push/pull paddle. If the door already has the ANSI mortise strike prep and you want to keep keyed storeroom control, the Schlage stays in the opening; if noise on a sleeping-room door is the driver, the 6800Q is the one built for it.
How fast can I get the Schlage L9080R02A626 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Schlage L9080R02A626 come with a warranty?
Absolutely. The Schlage L9080R02A626 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Schlage L9080R02A626?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Schlage L9080R02A626 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.