Schneider PowerPact Q 200A 3-P...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$2,556.67

Schneider PowerPact Q 200A 3-Pole Circuit Breaker 240VAC 65kA I-Line Thermal Magnetic

(No reviews yet) Write a Review

Model: QGA32200

In Stock (leaves warehouse same day if ordered before 3pm ET)

$2,556.67
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Schneider PowerPact Q 200A 3-Pole Circuit Breaker 240VAC 65kA I-Line Thermal Magnetic

Professional Power Distribution & Protection

The Schneider PowerPact Q series delivers reliable circuit protection with 200A continuous current rating and 65kA interrupting capacity at 240VAC. This 3-pole thermal-magnetic circuit breaker features I-Line mounting with bracket support and operating handle control, designed for distribution applications with HACR rating for HVAC systems.

Professional Features & Benefits

  • 200A Current Rating: Provides robust power handling capacity for demanding electrical distribution systems
  • 65kA Interrupting Capacity: Delivers superior fault current protection for enhanced system safety and reliability
  • Thermal-Magnetic Technology: Combines precise overload protection with fast short-circuit response for comprehensive circuit protection
  • I-Line Mounting: Enables efficient installation with bracket support system for secure panel integration
  • HACR Rated: Specifically certified for heating, air conditioning, and refrigeration applications
  • 3-Pole Configuration: Provides complete three-phase power distribution and protection
  • 80% Continuous Rating: Allows sustained operation at rated capacity for reliable long-term performance

Technical Specifications

  • Ambient Air Temperature For Operation: 40-70 °C
  • Average Life Duration: 15 year(s)
  • Carbon Footprint: 68.16642471
  • Carbon Footprint Kg Co2 Eq Total Life Cycle: 68.16642471
  • China Rohs In Scope: No
  • Circuit Breaker Application: HACR rated
  • Continuous Current Rating: 80%
  • Control Type: operating handle
  • Country Of Origin: Mexico
  • Device Application: distribution
  • Device Type: LV equipment - Low voltage circuit breaker
  • Distribution Carbon Footprint: 0.87158658
  • End Of Life Carbon Footprint: 5.090396046
  • Environmental Disclosure: ENVPEP2311048_V2
  • Eoli Availability Display: No need of specific recycling operations
  • Eu Rohs Directive: Compliant with Exemptions
  • Field Service Division: PPIBS
  • Function Option: Standard
  • Function Option Id: STANDARD
  • Green Premium Status For Reporting: Green Premium product
  • Halogen Content Performance: Halogen free product
  • Halogen Free Status: Halogen free product
  • Halogene Performance: Halogen free product
  • Installation Carbon Footprint: 0.582621661
  • Legacy Weee Scope: In
  • Magnetic Hold Current: 1200 A
  • Magnetic Tripping Current: 2400-2400 A
  • Manufacturing Carbon Footprint: 20.66999955
  • Mercury Free: Yes
  • Mounting Support: bracket
  • Network Frequency: 50/60 Hz
  • Package Weight Lbs: 3.039 kg
  • Packaging Made With Recycled Cardboard: Yes
  • Packaging Without Single Use Plastic: No
  • Phase Connection: ABC
  • Poles Description: 3P
  • Product Availability: Stock - Normally stocked in distribution facility
  • Product Contributes To Saved And Avoided Emissions: No
  • Product Depth: 3.93 in
  • Product Height: 6.47 in
  • Product Or Component Type: circuit breaker
  • Product Width: 4.5 in
  • Range: PowerPact
  • Reach Compliance Directive: Reference contains Substances of Very High Concern above the threshold
  • Reach Full Compliance Status: Reference contains Substances of Very High Concern above the threshold
  • Reach Full Compliance Status Id: CONTAINS_SVHC
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • Recycled Metal Content At Cr Level: 0%
  • Relationshiptype: Compatible relationship
  • Return Indicator: Y
  • Returnability: Yes
  • Rohs Eur Conformity Date: 1909
  • Rohs Eur Full Compliance Status: Compliant with Exemptions
  • Rohs Eur Full Compliance Status Id: COMPLIANT_WITH_EXEMPTIONS
  • Rohs Eur In Scope: Yes
  • Rohs Eur Status: Compliant with Exemptions
  • Rohs Exemption Information: Yes
  • Scope Perimeter: Outside of Europe
  • Serviceability: No
  • Sustainable Packaging: No
  • Take Back: No
  • Tier: 1
  • Tier Id: 1
  • Total Lifecycle Carbon Footprint: 68 kg CO2 eq.
  • Traceability: Yes
  • Trip Unit Technology: thermal-magnetic
  • Use Carbon Footprint: 40.95182088
  • Utilisation Category: category A
  • Wd Status: 1 - GSC certified
  • Wire Stripping Length: 22 mm
  • With Recycled Cardboard: Yes
  • Without Single Use Plastic: No
  • Department: Electrical

Professional Applications

  • Commercial Building Power Distribution
  • Industrial Facility Protection
  • HVAC System Circuit Protection
  • Multi-Unit Residential Properties
  • Retail and Office Buildings
  • Light Industrial Applications
  • Emergency Power Systems

Why Choose Schneider Quality?

Schneider PowerPact Q circuit breakers deliver proven reliability with 15-year average life duration and comprehensive environmental compliance. The halogen-free design and Green Premium status demonstrate commitment to sustainable electrical solutions while maintaining superior protection performance for critical power distribution applications.

Manufacturer Resources

Product Specs

Ambient Air Temperature For Operation:
40-70 °C
Average Life Duration:
15 year(s)
Carbon Footprint:
68.16642471
Carbon Footprint Kg Co2 Eq Total Life Cycle:
68.16642471
China Rohs In Scope:
No
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
80%
Control Type:
operating handle
Country Of Origin:
Mexico
Device Application:
distribution
Device Type:
LV equipment - Low voltage circuit breaker
Distribution Carbon Footprint:
0.87158658
End Of Life Carbon Footprint:
5.090396046
Environmental Disclosure:
ENVPEP2311048_V2
Eoli Availability Display:
No need of specific recycling operations
Eu Rohs Directive:
Compliant with Exemptions
Field Service Division:
PPIBS
Function Option:
Standard
Green Premium Status For Reporting:
Green Premium product
Halogen Content Performance:
Halogen free product
Installation Carbon Footprint:
0.582621661
Legacy Weee Scope:
In
Magnetic Hold Current:
1200 A
Magnetic Tripping Current:
2400-2400 A
Manufacturing Carbon Footprint:
20.66999955
Mercury Free:
Yes
Mounting Support:
bracket
Network Frequency:
50/60 Hz
Package Weight Lbs:
3.039 kg
Packaging Made With Recycled Cardboard:
Yes
Packaging Without Single Use Plastic:
No
Phase Connection:
ABC
Poles Description:
3P
Product Availability:
Stock - Normally stocked in distribution facility
Product Contributes To Saved And Avoided Emissions:
No
Product Depth:
3.93 in
Product Height:
6.47 in
Product Or Component Type:
circuit breaker
Product Width:
4.5 in
Range:
PowerPact
Reach Full Compliance Status:
Reference contains Substances of Very High Concern above the threshold
Recycled Metal Content At Cr Level:
0%
Relationshiptype:
Compatible relationship
Rohs Eur Conformity Date:
1909
Rohs Exemption Information:
Yes
Serviceability:
No
Sustainable Packaging:
No
Take Back:
No
Tier:
1
Total Lifecycle Carbon Footprint:
68 kg CO2 eq.
Traceability:
Yes
Trip Unit Technology:
thermal-magnetic
Use Carbon Footprint:
40.95182088
Utilisation Category:
category A
Wd Status:
1 - GSC certified
Wire Stripping Length:
22 mm
With Recycled Cardboard:
Yes
Without Single Use Plastic:
No
Department:
Electrical
Product Type:
Circuit Breaker
Product Group:
Circuit Breakers

Schneider QGA32200 – Frequently Asked Questions

1) Will the Schneider QGA32200 breaker mount in an I-Line panelboard?
Yes. The PowerPact Q QGA32200 is an I-Line breaker, 3-pole, connected ABC across the phases, and it mounts with a bracket support rather than bolt-on lugs. It plugs into the I-Line stack in a Schneider I-Line panelboard or switchboard. If your gear is a bolt-on or plug-on load center rather than I-Line, this is the wrong mounting style.
2) Is 65kA enough interrupting capacity for my service, and what voltage does that apply at?
The PowerPact Q 200A 3-pole is rated 65kA interrupting at 240VAC. Compare that against the available fault current calculated at your panel location; if the study shows more than 65kA at 240V, you need a higher AIC frame. It runs on 50/60 Hz systems.
3) What is the instantaneous trip setting on the PowerPact Q 200A?
It is a fixed thermal-magnetic trip unit, not adjustable electronic. Magnetic hold current is 1200 A and magnetic tripping current is 2400 A, so short circuits above that level clear instantaneously while thermal overloads trip on the bimetal curve. If your coordination study needs adjustable instantaneous or long-time pickup, you need an electronic trip frame instead.
4) Can an Eaton BAB series breaker be used instead of the QGA32200 200A 3-pole?
No. The Eaton BAB Quicklag is a bolt-on thermal-magnetic branch breaker, while the Schneider QGA32200 is a 3-pole molded case breaker with bracket mounting for I-Line distribution equipment. The two share thermal-magnetic tripping but not the mounting method or the frame, so a BAB device will not land in an I-Line panel. Use the BAB family for bolt-on load center branch circuits and the QGA32200 where a 3-pole I-Line feeder or HACR-rated HVAC feeder is called for.
5) What space do I need in the panel for a QGA32200?
The breaker measures 6.47 in high, 4.5 in wide and 3.93 in deep, and it weighs about 3.039 kg as packed. Use those figures to confirm interior clearance and the I-Line stack position before ordering.
6) How much insulation do I strip for the terminations on this breaker?
Wire stripping length is 22 mm at the terminals. Strip to that dimension so the conductor fully seats in the lug without leaving bare copper exposed outside it.
7) Can the trip unit on the PowerPact Q be repaired or field replaced?
No. The QGA32200 is listed as non-serviceable, so it is a sealed replace-on-fail device. Plan on stocking a spare breaker rather than parts. Stated average life duration is 15 years.
8) Does this Schneider breaker meet green procurement requirements for a LEED or sustainability spec?
It carries Schneider Green Premium status, is halogen free and mercury free, with environmental disclosure ENVPEP2311048_V2 and a total lifecycle carbon footprint of 68 kg CO2 eq. One caveat for EU-facing submittals: the reference contains Substances of Very High Concern above the REACH threshold, and RoHS status is compliant with exemptions. Country of origin is Mexico.
9) Is a Quicklag bolt-on breaker an alternative to the PowerPact Q 200A?
Not for the same job. The Eaton BAB Series Quicklag is a bolt-on thermal-magnetic branch breaker for load centers and panelboards, a different mounting style and a branch-circuit scale device. The PowerPact Q QGA32200 is an I-Line molded case breaker at 200A, 3-pole, bracket mounted. They are not interchangeable in the same enclosure.
10) Does the Eaton 10250T undervoltage release work with the Schneider PowerPact Q breaker?
Treat it as a separate item, not a substitute or an add-on. The Eaton 10250T series part is an undervoltage release for Eaton NZM molded case breakers, and the Schneider QGA32200 is the breaker itself, supplied with an operating handle as its control. If you need shunt or undervoltage tripping on a PowerPact Q, specify a Schneider accessory built for that frame rather than an Eaton NZM release.
11) I need a main breaker rather than a feeder device - is the Pow-R-Xpress kit the right call?
If the job is converting a panel to a main breaker configuration, the Eaton Pow-R-Xpress convertible main circuit breaker kit is the item built for that purpose. The Schneider QGA32200 is a standalone 200A 3-pole distribution breaker with bracket mounting, intended as a protective device in distribution equipment rather than sold as a panel conversion kit. Match the kit to Eaton Pow-R-Xpress panelboards, and use the QGA32200 where a 3-pole I-Line feeder position is being filled.
12) Is the PowerPact Q a switching duty breaker or just overcurrent protection?
It is operated by a handle and falls under utilisation category A, the standard non-selective category, and its application is distribution. Treat it as a distribution protective device with manual on/off at the handle, not as a frequently cycled motor switching contactor.
13) Is the Eaton 2TA401K terminal kit an alternative for landing conductors on this breaker?
The Eaton 2TA401K is a 400A Series C molded case breaker terminal accessory rated for Cu/Al conductors, and it is matched to the Eaton Series C frame rather than to the Schneider PowerPact Q. The QGA32200 accepts conductors at a 22 mm wire stripping length on its own terminations. Order lugs specified for the PowerPact Q frame if the installation needs a different termination.
How fast can I get the Schneider QGA32200 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Schneider QGA32200 come with a warranty?
Absolutely. The Schneider QGA32200 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Schneider QGA32200?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Schneider QGA32200 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.