Square D METSECTLV PowerLogic ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$3.06

Square D METSECTLV PowerLogic Split Core Current Transformer, 0.333V Output

(No reviews yet) Write a Review

Model: METSECTLV2010U

In Stock (leaves warehouse same day if ordered before 3pm ET)

$3.06
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Square D METSECTLV PowerLogic Split Core Current Transformer, 0.333V Output

The Square D METSECTLV PowerLogic Split Core Current Transformer is UL 2808 listed and IEC 61869-2 compliant, engineered for retrofit energy metering without the need to break existing circuit conductors. This split core CT is available across a Motor FLA range from 100A to 1200A, letting electricians match the transformer to the branch circuit or feeder being monitored while sharing the same 0.333V output signal, 8 ft flying lead (AWG 16, 600V), and PowerLogic meter compatibility across the entire family. It is rated for both 50 Hz and 60 Hz networks and interfaces directly with PowerLogic BCPM, BCPMSC, EM3500, EM4200, EM4900, and iEM3000 meters.

Key Features

  • Motor FLA Range: Available in 100A, 600A, 800A, and 1200A ratings to match the monitored circuit.
  • Split Core Construction: Split core type allows installation around energized conductors without disconnecting the circuit.
  • Output Signal: 0.333V output for direct PowerLogic meter interface across the entire family.
  • Electrical Connection: 8 ft flying lead, AWG 16, rated 600V.
  • Network Frequency: Compatible with 50 Hz and 60 Hz systems.
  • Measurement Accuracy: 1% accuracy class across all Motor FLA options.
  • Operating Range: -15-60 °C operation, -40-70 °C storage.
  • Meter Compatibility: PowerLogic BCPM, BCPMSC, EM3500, EM4200, EM4900, iEM3000.

Certifications & Compliance

  • UL 2808 Listed
  • IEC 61869-2 Compliant
  • RoHS EU Compliant
  • REACH Compliant – Free of Substances of Very High Concern
  • Mercury Free and Toxic Heavy Metal Free

Technical Specifications

  • Country of Origin: Mexico
  • Measurement Accuracy: 1 %
  • Ambient Air Temperature For Operation: -15-60 °C
  • Mercury Free: Yes
  • Toxic Heavy Metal Free: Yes
  • ROHS Eur In Scope: Yes
  • Reach Free Of Svhc: Yes

Typical Applications

  • Commercial and Industrial Energy Metering
  • Retrofit Split Core CT Installations
  • PowerLogic Multi-Circuit Energy Meter Systems
  • Panelboard and Switchgear Power Monitoring
  • Submetering for Load Center Circuits

Why Square D?

Square D PowerLogic current transformers are built to UL 2808 and IEC 61869-2 standards for dependable, code-compliant energy metering across the full 100A-1200A Motor FLA lineup. This split core CT family is mercury free and toxic heavy metal free, with RoHS EU and REACH conformity confirming it is free of Substances of Very High Concern, supporting reliable power monitoring for professional electrical work.

Manufacturer Resources

Product Specs

Product Type:
Current Transformer
Configuration:
Split Core
Voltage Rating:
0.333V
Standards:
IEC 61869-2
Country of Origin:
Mexico
Department:
Electrical
Product Group:
Power Distribution
Amperage Rating:
100A - 1200A
Listing:
UL 2808
Product Subgroup:
Energy Monitoring

Square D METSECTLV2010U – Frequently Asked Questions

1) Can I install a PowerLogic split core CT without shutting down the circuit?
That is the point of the split core design. The Square D PowerLogic CT opens and closes around an existing conductor, so you do not have to break or pull the conductor to get it on. It is aimed at retrofit energy metering in live panelboards and switchgear where taking the circuit down is not an option. Standard electrical safety practice for working near energized conductors still applies.
2) Which meters does the Square D 0.333V split core CT work with?
It is built for the PowerLogic line: BCPM, BCPMSC, EM3500, EM4200, EM4900, and iEM3000. The 0.333V low-voltage output feeds those meter inputs directly. If your meter expects a 5A secondary instead of a millivolt signal, this is the wrong CT for it.
3) What amperage ranges are offered on this Square D split core CT?
Four primary current ratings: 100A (METSECTLV2010U), 600A (METSECTLV3060U), 800A (METSECTLV4080U), and 1200A (METSECTLV4120U). Size the CT to the breaker or feeder rating it is monitoring, not to the measured load, so the meter reads across the full expected range.
4) How long are the leads, and do I need to run them in conduit back to the meter?
Each CT ships with an 8 ft flying lead, AWG 16, rated 600V. That 600V insulation rating is what lets the lead share raceway with power conductors under normal wiring practice. If the meter is more than 8 ft from the CT location, plan a junction and extension, because the lead is not field-lengthened at the CT.
5) Is this CT accurate enough for tenant submetering?
The PowerLogic split core CT is a 1 percent accuracy class device and is UL 2808 listed, the standard written specifically for energy monitoring equipment. It is also IEC 61869-2 compliant. For revenue-grade billing, confirm what your local utility or jurisdiction requires of the meter itself, since the meter and the CT are rated separately.
6) Can these be mounted inside a switchgear enclosure that runs hot?
Operating range is -15 to 60 degrees C, with storage from -40 to 70 degrees C. That covers most indoor panelboard and switchgear cabinets, but a poorly ventilated enclosure near the top of a warm electrical room can exceed 60 C in summer, so check the internal temperature rather than the room temperature before committing.
7) Should I use a split core or solid core CT for a panel that is already in service?
Split core, every time, on an existing energized panel. A solid core CT is a closed ring, so the conductor has to be disconnected and threaded through it, which means an outage. The PowerLogic split core hinges open over the conductor in place. Solid core is the better choice only on new construction where the conductor is not yet terminated.
8) Will these CTs work on a 50 Hz system for an export or overseas project?
Yes, the Square D PowerLogic split core CT is rated for both 50 Hz and 60 Hz networks, so the same part works on North American and 50 Hz installations. Country of origin is Mexico.
9) Does the Square D split core CT meet RoHS and REACH for an environmentally specified project?
It is RoHS EU compliant and REACH compliant, free of Substances of Very High Concern, plus mercury free and toxic heavy metal free. Useful documentation for LEED submittals and public-sector procurement that screens for restricted substances.
How fast can I get the Square D METSECTLV2010U delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Square D METSECTLV2010U come with a warranty?
Absolutely. The Square D METSECTLV2010U is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Square D METSECTLV2010U?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Square D METSECTLV2010U from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.