Altronix AL300ULB
Power Supply Charger, Single Class 2 Output, 12/24VDC @ 2.5A, 28VAC, Board
Specifications
-
Input
- Input 28VAC/100VA.
-
Output
- 12VDC or 24VDC selectable output.
- 12VDC or 24VDC @ 2.5A supply current.
- Filtered and electronically regulated output.
- Short circuit and thermal overload protection.
-
Battery Charging
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails.
-
Supervision
- AC fail supervision (form "C" contacts).
- Low battery supervision (form "C" contacts).
-
Visual Indicators
- AC input and DC output LED indicators.
-
Electrical
- Operating temperature: 0ºC to 49ºC (32ºF to 120ºF).
- Storage temperature: -20ºC to 70ºC (-4ºF to 158ºF).
- Relative Humidity 85% +/- 5%.
-
BTU/Hr. (approx.):
- 12VDC: 17 BTU/Hr.
- 24VDC: 32 BTU/Hr.
- System AC input VA requirement: 115VA.
Dimensions & Weight
Dimensions (approximate):
- 4"W x 7"L x 1.75"H (101.6 mm W x 177.8 mm L x 51.05 mm H).
Weights (approximate):
- Product Weigtht: 1.05 Lbs. (0.48 kg).
- Shipping Weigtht: 1.25 Lbs. (0.57 kg).
Manufacturer Resources
Product Specs
- Warranty:
- Lifetime
- Subcategory:
- Access Power Controller With Power Supplies
- Commercial/Residential:
- Commercial
- Product Group:
- Electronic Access Controls
- Product Subgroup:
- Power Supplies
- Product Type:
- Boards
- Product Voltage:
- 120V
- Product Category:
- Electronic Access Controls
- Department:
- Door Hardware
Altronix AL300ULB – Frequently Asked Questions
1) Will the Altronix AL300ULB power supply board run 12VDC and 24VDC locks, or do I have to pick one?
One at a time. The AL300ULB is a selectable board: you set it for either 12VDC or 24VDC output, and it delivers 2.5A at whichever you choose. There is a single Class 2 output, so a mixed job with 12V strikes and 24V maglocks needs either two boards or a separate supply for the odd voltage out.
2) What input power does the Altronix AL300ULB board need at the wall?
The board itself takes 28VAC at 100VA on its input, fed from a transformer off a 120V circuit. Plan the system side for 115VA of AC input. This is a board only, so the transformer and enclosure have to come from somewhere else on the order.
3) Will the AL300ULB keep my access control doors powered when the building loses AC?
Yes, if you add batteries. The board has a built-in charger for sealed lead acid or gel batteries and switches over to standby battery automatically when AC fails. It also gives you form C dry contacts for AC fail and for low battery, so the panel or head end can annunciate the outage instead of you finding out when a door stops reading.
4) Can I use an Altronix AL300ULB to replace the failed board inside a Von Duprin PS873 power supply?
No. The AL300ULB is a standalone charger board sized to its own 28VAC input and enclosure, not a drop-in for a Von Duprin can. The part built for that swap is the Command Access VD2-873, a replacement relay board for the PS873 power supply.
5) Is the Altronix AL300ULB a complete power supply or just the board?
Board only. You get the charger and power supply electronics with AC input and DC output LED indicators for troubleshooting at the door, but no enclosure, no transformer, and no batteries. Budget for a can, a 28VAC transformer, and sealed lead acid or gel batteries sized to the standby time the job calls for.
6) Can a Command Access DS1+ board be used in place of an Altronix AL300ULB?
No. The AL300ULB is a power supply charger board that takes 28VAC input and delivers a single Class 2 filtered, electronically regulated 12VDC or 24VDC output at 2.5A, with a built-in charger for sealed lead acid or gel batteries and automatic switch over to standby battery on AC failure. The Command Access DS1+ is a delay/sequencer board with bi-directional control that operates at 12-24VDC, meaning it is powered from a supply rather than being one. A DS1+ sequences the release order of devices on an opening; it will not charge a battery or regulate an output, so it complements an AL300ULB rather than replacing it.
7) What board handles door sequencing if the Altronix AL300ULB only provides power?
The AL300ULB provides the power side of the opening: a selectable 12VDC or 24VDC Class 2 output at 2.5A with short circuit and thermal overload protection, AC fail and low battery supervision on form C contacts, and AC input and DC output LED indicators. For the logic side, the Command Access DS1-X is a multi-function door sequencing relay board with 13 programmable functions, and the DS1+ is a delay/sequencer board with bi-directional control. Those two handle timing and sequencing between a lock, an operator, and a release device, while the AL300ULB feeds them regulated DC and holds up the opening on battery when AC drops.
8) Can I mount an AL300ULB in an unheated garage, warehouse, or outdoor equipment room?
Only where the space stays between 0C and 49C (32F to 120F), which is the operating range for the board, at up to 85% relative humidity. An unheated northern garage drops below that in winter. Shipping and dead storage tolerate more, -20C to 70C (-4F to 158F), but that is storage, not running.
9) Is 2.5A enough for my door hardware, and how do I size it?
2.5A at the selected voltage is the ceiling for everything hanging on the single output, and the battery charging draws off the same supply. Add up the holding current of every maglock or strike plus the readers and controller on that run and leave headroom for the inrush when several doors release at once. A large multi door opening or a bank of maglocks will outrun a 2.5A board.
10) What happens if an access control field wire shorts out on an AL300ULB?
The output carries short circuit and thermal overload protection, so a pinched strike wire or a shorted maglock lead shuts the output down rather than cooking the board. Output is filtered and electronically regulated, which matters for readers and boards that misbehave on unregulated ripple.
11) Do I need a power supply board or a door sequencing relay board?
Two different jobs. The AL300ULB makes and conditions the power: 12 or 24VDC at 2.5A with battery backup and supervision. It does not sequence hardware. If what you need is timed release of an electric latch retraction device against an operator, or bi-directional control across a pair, that is a sequencer such as the Command Access DS1+ delay/sequencer board, or the DS1-X with its 13 programmable functions. Those boards still need a supply feeding them.
12) For a 24VDC opening, does choosing the Altronix AL300ULB lock in a separate 12VDC supply for the accessories?
Not necessarily on the accessory side. The AL300ULB output is selectable between 12VDC and 24VDC at 2.5A, so a single board can be set to whichever the opening needs, and the Command Access DS1+ delay/sequencer and the DS1-X sequencing relay board are rated across 12-24VDC, so they run from either setting. Where a second supply becomes necessary is when the lock and the accessories need different voltages at the same time, since the AL300ULB carries one Class 2 output and one selected voltage.
13) Is the AL300ULB suitable for a commercial building or is it a residential product?
It is a commercial access control supply, running on a 120V service with 28VAC to the board, and it is the kind of unit that goes in an equipment room feeding card readers, strikes, and maglocks. The form C AC fail and low battery contacts exist so a facility can monitor it, which is not something a residential product bothers with.
How fast can I get the Altronix AL300ULB delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the
continental
U.S.
Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit,
reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Altronix AL300ULB come with a warranty?
Absolutely. The Altronix AL300ULB is backed by a manufacturer’s warranty.
For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Altronix AL300ULB?
You can call, text, or email our expert support team for fast answers. We’re here to help with
product
selection,
installation tips, and troubleshooting. Contact Us
Why buy the Altronix AL300ULB from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support,
and
rewards on
every order.
Our team is always ready to help you choose the right product for your project.