B-Line Eaton series meter s, 1...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$2,982.01

B-Line Eaton series meter s, 100 A, Single meter position, Ring type, 3R, Underground, ANSI 61 gray painted, 010 kAIC, #14 - 2/0, MCB, 100 A, 2P, Gal

(No reviews yet) Write a Review

Model: U1M1R
Selected Model is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$2,982.01
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks
Eaton B-Line series meter breakers, 100 A, Single meter position, Ring type, 3R, Underground, ANSI 61 gray painted, 010 kAIC, #14 - 2/0, MCB, (1) 100 A, 2P, Galvanized steel, Surface mount, 4 jaws, 3 wires, 1 phase, 1Ø/3W, 120/240 V

Manufacturer Resources

Product Specs

Amperage Rating:
100A
Application:
Single meter position
Bus Material:
Aluminum
Certifications:
UL
Compliances:
EUSERC Approved
Interrupt Rating:
10 kAIC
Main Circuit Breaker:
(1) 100 A, 2P
Phase:
Single-phase
Product Height:
24 in
Product Length Depth:
4.625 in
Product Weight:
28 lb
Product Width:
14 in
Voltage Rating:
120/240V
Department:
Electrical
Product Finish:
ANSI 61 gray paint
Product Material:
Galvanized steel

B-LINE U1M1R – Frequently Asked Questions

1) Will the Eaton B-Line U1M1R meter breaker work on a 120/240V single-phase residential service?
Yes. The U1M1R is built for 120/240 V, single-phase, 3-wire service with a 4-jaw meter socket, which is the standard residential and small commercial overhead/underground arrangement. It carries one 100 A, 2-pole main breaker and is rated 100 A overall.
2) Is the U1M1R meter socket for an overhead drop or underground service?
Underground. The U1M1R is configured for underground service entrance, so it has no weatherhead/overhead hub provision. If the utility is feeding you from a pole with an overhead drop, you need an overhead-configured meter breaker instead.
3) Does this meter socket take a sealing ring, or is it a ringless cover?
It's a ring type socket, meaning the cover is retained by a sealing ring rather than a ringless-style bolted-on hub cover. Most utilities specify one or the other, so match the utility's requirement before ordering, as a ringless utility will reject a ring type can.
4) What wire size can I land in the Eaton B-Line 100 A meter breaker?
The lug range is #14 through 2/0, covering the usual copper and aluminum conductors used on a 100 A service. Bus is aluminum, so use the appropriate dual-rated compression or mechanical lugs and anti-oxidant compound on aluminum conductors.
5) Can the U1M1R be mounted outdoors on an exterior wall?
Yes. It's a NEMA 3R enclosure, rain-tight for outdoor surface mounting, in galvanized steel with ANSI 61 gray paint. Mounting is surface, so it bolts flat to the wall or a strut rack rather than recessing into the wall.
6) Is this meter breaker EUSERC approved for West Coast utilities?
Yes, the U1M1R is EUSERC Approved and UL listed. That matters in the western states where utilities require EUSERC-conforming metering equipment before they will set a meter and energize the service.
7) Is a 10 kAIC interrupting rating enough for my service?
The main breaker in the U1M1R is rated 10 kAIC at 120/240 V. On a typical residential or small commercial 100 A single-phase service that is normally adequate, but if the utility's available fault current at the service point exceeds 10 kA, you need equipment with a higher interrupting rating. Ask the utility for the available fault current before you commit.
8) Does the U1M1R include branch circuit spaces, or do I still need a panelboard?
It's a meter-main combination: one meter position with a single 100 A, 2-pole main breaker. There are no branch breaker spaces, so you feed a separate load center downstream for your branch circuits. If you want metering and branch circuits in one can, you need a meter load center rather than this meter breaker.
9) What space do I need to plan for this meter breaker on the wall?
Plan for 24 in high by 14 in wide, with 4.625 in of depth off the wall face. It weighs 28 lb, so one person can hang it, but block or strut backing is worth having on stucco or siding. Leave the working clearance your local code requires in front of the meter.
10) Can I use this for a duplex or two-unit building where both tenants need their own meter?
No. The U1M1R has one meter position only. A two-unit building needs a two-position meter stack or two separate meter breakers, one per tenant, per the utility's metering requirements.
How fast can I get the B-LINE U1M1R delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the B-LINE U1M1R come with a warranty?
Absolutely. The B-LINE U1M1R is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the B-LINE U1M1R?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the B-LINE U1M1R from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.