BEA 10MATRIXD1224 MATRIX FAMIL...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$230.52
$179.34

BEA 10MATRIXD1224 MATRIX FAMILY Dual Loop Detector with Automatic Sensitivity Boost 12-24V AC/DC

(No reviews yet) Write a Review

Model: BEA-10MATRIXD1224

In Stock (leaves warehouse same day if ordered before 3pm ET)

$230.52
$179.34
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

BEA 10MATRIXD1224 MATRIX FAMILY Dual Loop Detector with Automatic Sensitivity Boost 12-24V AC/DC

Professional Induction Loop Vehicle Detection System

The BEA 10MATRIXD1224 MATRIX FAMILY dual loop detector delivers reliable vehicle detection for industrial environments with UL 508 listing and automatic boost sensitivity technology. Operating on 12-24V AC/DC power, this induction loop detector features dual loop detection capability with pulse on entry and pulse on exit functionality. Engineered for demanding commercial applications requiring precise vehicle detection and monitoring.

Professional Features & Benefits

  • Dual Loop Detection: Independent dual loop detection settings provide enhanced vehicle monitoring and traffic management capabilities.
  • Automatic Boost Sensitivity (ABS): Advanced sensitivity adjustment automatically optimizes detection performance for varying environmental conditions.
  • Flexible Power Options: 12-24V AC/DC operation accommodates various system voltage requirements for versatile installation options.
  • UL 508 Listed: UL certification ensures compliance with safety standards for industrial control equipment applications.
  • Pulse Detection Modes: Pulse on entry and pulse on exit functionality provides precise vehicle movement tracking and control.
  • Industrial-Grade Design: Engineered specifically for vehicle detection applications in demanding industrial environments.
  • MATRIX FAMILY Compatibility: Part of the comprehensive MATRIX FAMILY series offering consistent performance and integration options.

Technical Specifications

  • Tuning: Automatic
  • Connector: 11-pin male (86CP11)
  • Presence Time: 1 min - infinity
  • Pulse Time Output: 100 ms or 500 ms
  • LED Indicators: Power: Green | Loop Status 1: Red | Loop Status 2: Red
  • Frequency Range: 20 kHz - 130 kHz
  • Sensitivity: 0.005% - 0.5%
  • Reaction Time: Single Loop: 25 ms | Double Loop: 50 ms (each channel)
  • Setup Time After Configuration: 2 s max by channel
  • Power Supply: 12 - 24 AC/DC +/-10% or 115 VAC +/-10% (depending on model)
  • Power Frequency: 48 - 62 Hz
  • Power Consumption: < 2.5 W
  • Temperature Range: -22 deg. F - 158 deg. F (-30 deg. C - 70 deg. C)
  • Inductance Range: 20 uH - 1000 uH
  • Relay Outputs: 2 (free potential change-over contact)
  • Max Contact Voltage: 230 VAC
  • Max Contact Current: 5 A (resistive)
  • Setup Time at Power On: MATRIXD: 8 s max | MATRIXIIS: 8 s max | MATRIX-3S: 1.6 s max | MATRIX-3D: 2.2 s max
  • Norm Conformance: R&TTE: 1999/5/EC; EMC: 89/336/EEC; EMC: 2004/108/EC; FCC: 47 CFR 15; IC: RSS-210; UL Listed for UL 508

Installation & Operation

  1. Verify electrical requirements match available power supply. Confirm 12-24V AC/DC voltage and current capacity before proceeding.
  2. Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
  3. Mount the unit in the specified location ensuring adequate clearance for wiring access, ventilation, and future service requirements.
  4. Route and connect wiring according to manufacturer wiring diagrams. Use appropriate wire gauge and connectors for the application.
  5. Configure operational settings including automatic boost sensitivity and dual loop detection parameters per application requirements.
  6. Restore power and test all functions including normal operation, pulse on entry/exit detection, and integration with connected vehicle management systems.
  7. Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.

Professional Applications

  • Industrial Facility Vehicle Access Control
  • Warehouse and Distribution Center Traffic Management
  • Commercial Parking Facility Entry Systems
  • Manufacturing Plant Vehicle Detection
  • Loading Dock Automation Systems
  • Security Gate Vehicle Monitoring
  • Traffic Flow Management Systems

Why Choose BEA Quality?

BEA MATRIX FAMILY loop detectors deliver professional-grade reliability with UL 508 listing and automatic boost sensitivity technology for demanding industrial vehicle detection applications. The dual loop detection capability with pulse on entry and exit functionality ensures precise monitoring and control. Engineered for industrial environments where dependable vehicle detection performance is essential.

Product Specs

Product Type:
Loop Detector
Series:
MATRIX FAMILY
Subcategory:
Sensors, Switches, Relays and Timers
Commercial/Residential:
Commercial
Electronic:
Yes
Product Group:
Electronic Access Controls
Product Subgroup:
Sensors, Switches, Relays and Timers
Product Category:
Electronic Access Control
Department:
Door Hardware

BEA BEA-10MATRIXD1224 – Frequently Asked Questions

1) Will the BEA 10MATRIXD1224 loop detector plug into an 11-pin socket base I already have on the gate operator?
Yes, provided the base is the 11-pin type. The 10MATRIXD1224 uses an 11-pin male connector (BEA references it as the 86CP11), so it drops into a standard 11-pin socket base. If the existing base is an 8-pin or 4-pin harness style, this unit will not seat and you need a different detector form factor.
2) Can I run a BEA MATRIX dual loop detector off 24VDC, or does it need line voltage?
The 10MATRIXD1224 runs on 12 to 24V AC or DC, plus or minus 10 percent, so a 24VDC operator supply or a 12VAC transformer both work. Draw is under 2.5W. There is a separate 115VAC version in the MATRIX range, so if you are feeding it line voltage you want that model instead, not this one.
3) Do I need one detector per loop, or can one unit handle both the entry and exit loop at a gate?
One 10MATRIXD1224 handles two loops. It has two independent channels with their own sensitivity settings and two relay outputs, each a free-potential changeover contact, so a single unit covers an entry loop and an exit loop, or an arming loop and a safety loop, without a second detector in the panel.
4) Can this detector hold a gate open as long as a vehicle sits on the loop?
Yes. Presence time is settable from 1 minute to infinity, so a channel can be configured to hold its output for as long as the vehicle stays over the loop, which is what you want on a safety or reversing loop. For a momentary trigger instead, each channel can pulse on entry or on exit with a 100 ms or 500 ms output.
5) Will the relay contacts on this loop detector switch a 120V gate motor circuit directly?
The two relay outputs are rated to 230 VAC max contact voltage and 5 A resistive, so a 120V control circuit is within rating. They are dry changeover contacts, meaning no voltage is supplied by the detector itself. For an inductive load like a motor, the 5 A figure is resistive, so switch a contactor rather than the motor windings.
6) Will a saw-cut loop in my driveway be within the detector's inductance range?
The MATRIX detector tunes loops from 20 uH to 1000 uH across a 20 kHz to 130 kHz frequency range, which covers typical saw-cut preformed loops with normal feeder lengths. Tuning is automatic, so you do not set dip switches for loop size. Frequency is selectable to keep adjacent loops from crosstalking.
7) What does automatic boost sensitivity actually do on a BEA MATRIX loop detector?
Automatic boost sensitivity raises the channel's sensitivity once a vehicle is detected and holds it there, so a high-bed truck or a trailer with a long gap under it does not drop out mid-pass and let the gate close on it. Base sensitivity is adjustable from 0.005 percent to 0.5 percent of inductance change.
8) Is this loop detector rated for an unheated outdoor gate cabinet in a cold climate?
Operating range is -22 to 158 degrees F (-30 to 70 degrees C), so an unheated roadside cabinet in a cold-winter or hot-sun location is within spec. The unit still needs to be in an enclosure, and it carries a UL 508 Listing as industrial control equipment.
9) How do I tell at a glance which loop is faulting during a service call?
Three LEDs on the front: green for power, and a separate red indicator for Loop Status 1 and Loop Status 2. That splits the two channels visually, so a tech standing at the cabinet can see whether the fault is a single bad loop in the pavement or a power problem, without pulling the unit from its base.
How fast can I get the BEA BEA-10MATRIXD1224 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the BEA BEA-10MATRIXD1224 come with a warranty?
Absolutely. The BEA BEA-10MATRIXD1224 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the BEA BEA-10MATRIXD1224?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the BEA BEA-10MATRIXD1224 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.

Videos