Command Access PD15/16 Complet...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$930.00
$608.98

Command Access PD15/16 Complete Motorized Storefront Exit Device for Kawneer 1686/1786 & Jackson 1285/1295 Retrofit

(No reviews yet) Write a Review

Model: PD15-M-RIM 36 628
$930.00
$608.98
Selected Finish is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$930.00
$608.98
Adding to cart… The item has been added
Free Shipping on orders over $99
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

PD15/16 SeriesMotorized Storefront Exit Device for Kawneer 1686/1786 & Jackson 1285/1295 Retrofit

The Command Access PD15-M Series is a premium-grade motorized latch pullback exit solution designed to retrofit seamlessly with Kawneer 1686 exit device, Kawneer 1786, and Jackson CRL Model 1285 / 1295 Rim Panic Devices. Engineered for versatility, the PD15-M kit installs using existing door prep and mounting holes—eliminating the need to remove the door.

This makes it the ideal retrofit kit for storefronts and other commercial applications where a Kawneer 1686 EL or Jackson exit device 1285 needs to be electrified for access control. With UL certification available via the PD15 UL M Kit, this exit device upgrade offers a safe, dependable, and code-compliant solution for today’s demanding environments.


? Key Features

  • Motorized Latch Retraction
    Optimized for Kawneer 1686 panic bars, Jackson panic bar 1285, and similar storefront exit hardware.

  • MM4 Smart Module
    Built-in diagnostics with audible feedback simplify power management and installation troubleshooting.

  • PTS “Push-to-Set” Technology
    5-second electronic adjustment post-install ensures a perfect fit without door removal.

  • Electric Dogging
    Rated for continuous duty—auto re-engages if push pad is pulled from dogged position.

  • Dual Torque Modes
    Switch between Low Current or High Torque to suit varying door conditions.

  • Long Wire Runs
    Supports 300 feet with 2-conductor 18 AWG cable—ideal for centralized power supply rooms.

  • Quick Connect Wiring
    Includes 8-foot harness with plug-in connection to MM4 smart module.

  • UL Listed
    Available with PD15 UL M Kit for UL-compliant installations in fire/life-safety applications.

  • 3-Year “No Hassle” Warranty
    Comprehensive support for all retrofit applications.


⚙️ Specifications

  • Input Voltage Range: 24–25.3 VDC

  • Overvoltage Protection: Shuts down above 28VDC

  • Current Draw:

    • Standard Mode: 1.3A Peak / 170mA Hold

    • High Torque Mode: 2A Peak / 250mA Hold

  • Push Bar Sizes: 36” and 48” (field trimmable)

  • Compatible Door Thickness: Standard 1-3/4”

  • Stile Compatibility: Narrow, medium, and wide stile; minimum 2” stile

  • Projection:

    • 2-5/8” fully projected

    • 1-5/8” when dogged

  • Dogging Options:

    • Standard: Hex key

    • Optional: Cylinder or electric dogging

  • Handing:

    • RIM models: Non-handed

    • CVR models: Handed

  • Vertical Rods (CVR Devices):
    Adjustable steel top and bottom rods

  • Mounting: Self-tapping screws included


? Compatible Devices for Retrofit:

  • Kawneer 1686 EL / 1786 Exit Device

  • Jackson Exit Device Model 1285 / 1295

  • Jackson 1295 Rim Panic & CRL 1285

  • Storefront aluminum doors using narrow stile panic bars


Whether you're retrofitting a Jackson panic bar 1285 or modernizing a Kawneer 1686 exit device, the PD15/16 Series is engineered to deliver fast installation, reduced labor, and superior reliability in every access control setup.


The Command Access PD15-M series is a field-friendly, access control-ready upgrade for any facility looking to retrofit the Kawneer 1686 or similar storefront panic bar hardware. Whether you're specifying for new construction or modernization, this is the dependable solution installers trust.

PD15-M Cutsheet

Installation Instructions

Manufacturer Resources

Product Specs

Product Group:
Exit Devices and Trim
Series:
PD15/16 Series
Subcategory:
Exit Device Trim
Commercial/Residential:
Commercial
Electronic:
Yes
Product Subgroup:
Motorized & Electrified Exit Devices
Grade:
Grade 1
Tags:
pd15 ul m kit, kawneer 1686 exit device, kawneer 1686 el, kawneer 1686 panic device, kawneer panic bar 1686
Product Category:
Exit Devices and Trim

Command Access PD15-M-RIM 36 628 – Frequently Asked Questions

1) What door types is the Command Access PD15-16 compatible with?
This device is designed specifically for Kawneer 1686, 1786, Jackson 1285, and 1295 storefront systems as a retrofit solution. It works on aluminum storefront doors typically 1-3/4" thick. Verify your existing door frame matches these specifications before ordering.
2) How do I determine the correct door handing for this exit device?
Stand outside the door looking at the hinges. If hinges are on your right, order right-hand (RH). If hinges are on your left, order left-hand (LH). The PD15-16 is field-reversible but proper handing ensures optimal installation.
3) What power requirements does this motorized exit device need?
The unit typically requires 12V or 24V DC power supply. Check your access control system voltage before installation. A dedicated power supply may be required depending on your existing system capacity and wire run distance.
4) What grade and fire rating does this device meet?
Command Access exit devices typically meet UL Grade 1 commercial standards. Fire rating depends on door assembly and installation. Consult local code officials for specific fire rating requirements in your application.
5) Does this work with existing access control systems?
Yes, the PD15-16 integrates with most access control systems. It accepts standard request-to-exit and access granted signals. Verify voltage compatibility and signal requirements with your access control manufacturer before installation.
6) What finish options are available?
Standard finishes include aluminum, dark bronze, and black. Custom finishes may be available for large projects. The finish should match your existing storefront hardware for consistent appearance.
7) What components are included in the complete kit?
Complete kits typically include the motorized exit device, strike plate, mounting hardware, and installation template. Power supply and low-voltage wiring are usually sold separately. Verify all components needed for your specific installation.
8) How difficult is the retrofit installation process?
Installation requires commercial door hardware experience. The retrofit design minimizes frame modification but precise measurement and alignment are critical. Plan for electrical rough-in and system programming time beyond mechanical installation.
9) How do I adjust the door closing force and speed?
Motorized units typically have electronic adjustment controls accessible through the access control system or local programming interface. Follow manufacturer instructions for force and timing adjustments to meet ADA compliance requirements.
10) What are common field measurement requirements?
Measure door thickness, frame dimensions, and verify the existing storefront system model. Check for adequate clearance above and below the device mounting area. Confirm electrical rough-in locations match the device requirements.
11) Are there similar models for other storefront systems?
Command Access offers various models for different storefront manufacturers. Each model is engineered for specific frame profiles. Contact technical support to identify the correct model for non-Kawneer or non-Jackson applications.
12) What maintenance does this motorized exit device require?
Regular maintenance includes cleaning contacts, checking mounting hardware torque, and verifying proper operation cycles. Test emergency egress function monthly. Schedule annual professional inspection for optimal performance and code compliance.
How fast can I get the Command Access PD15-M-RIM 36 628 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Command Access PD15-M-RIM 36 628 come with a warranty?
Absolutely. The Command Access PD15-M-RIM 36 628 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Command Access PD15-M-RIM 36 628?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Command Access PD15-M-RIM 36 628 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.