Philips Lighting Core & Coil M...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$441.77

Philips Lighting Core & Coil Metal Halide Ballast 35/39W M130 120V Magnetic HID System

(No reviews yet) Write a Review

Model: 71A5005500DP
Selected Model is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$441.77
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Philips Lighting Core & Coil Metal Halide Ballast 35/39W M130 120V Magnetic HID System

Professional magnetic ballast for reliable metal halide lamp operation

The Philips Lighting Core & Coil Metal Halide Ballast delivers dependable performance for 35/39W metal halide lamps with M130 ANSI code compatibility. This magnetic HID ballast operates on 120V at 60Hz with HX-HPF circuit design, featuring UL Recognized components with CSA certification and RoHS compliance. The system includes integrated capacitor and ignitor components with Class H insulation rating for reliable outdoor and indoor applications.

Professional Features & Benefits

  • 35/39W Power Rating: Optimized for standard metal halide lamps with consistent wattage delivery and 10% constant wattage deviation tolerance.
  • M130 ANSI Compatibility: Ensures proper lamp matching and reliable ignition with standardized electrical characteristics.
  • Magnetic HID Design: Proven core and coil technology provides stable operation with 0.9 power factor for efficient performance.
  • 120V Operation: Standard line voltage compatibility with 60Hz frequency for widespread installation flexibility.
  • UL Recognized Components: Class H insulation rating (180�C) with CSA certification ensures safety and code compliance.
  • Outdoor Rated: Suitable for outdoor use with robust construction and temperature marking for versatile applications.
  • Remote Wiring Capability: Supports remote ballast installation up to 15 feet from lamp for flexible mounting options.

Technical Specifications

  • Allowed Wiring Config Remote: Yes
  • Ansi Code: M130
  • Approbation Marks: ULR, CSA, RoHS
  • Automatic Restart: No
  • Ballast Factor: 1 -
  • Ballast Type: Magnetic HID
  • Bar Code On Case: 5.07811E+13
  • Bar Code On Pack: 7.81087E+11
  • Base Model: 71A5005P
  • Brandlabel: PHILIPS ADVANCE
  • Capacitor Catalog Number: 7C280M12RA
  • Capacitor Dia Oval Dim: 1.65 in
  • Capacitor Height: 2.75 in
  • Capacitor Requirements: 120V
  • Capacitor Temp Rating: 105�C
  • Capacitor Value F: 28 MFD
  • Catalog: 71A5005500DP
  • Ccc Certificate: No
  • Ce Marking: No
  • Cec Listing: No
  • Chia Quality Certificate: No
  • Circuit Type: HX-HPF
  • Coil Depth C1: 1.7 in
  • Constant Wattage Deviation: 10%
  • Core Size: 2 X 4
  • Csa Certificate: Yes
  • Cul Certificate: No
  • Eisa: No
  • Eop Net Weight Pp: 1.166 kg
  • Etl Certificate: No
  • Family Name: Core & Coil MH
  • Fide Certificate: No
  • Full Product Name: MH BAL 35/39W M130 120V C&C
  • Gtin: 7.81087E+11
  • Hipot Test 1 Minute: 2000 V
  • Hipot Test 2 Seconds: 2500 V
  • Idwindex: 7583614
  • Idwitemctrl: 7.81087E+11
  • Igcc: 3708
  • Ignitor Catalog Number: LI533-H4
  • Ignitor Temp Rating: 105�C
  • Inp Current Open Circuit: 1.1 A
  • Input Current Operating: 0.5 A
  • Input Current Starting: 0.45 A
  • Input Current Short Circuit: 0.3-0.5 A
  • Input Power Gear: 55 W
  • Input Voltage At Lamp Dropout: 100 V
  • Lamp Type: 35/39W MH
  • Length A1: 4.2 in
  • Line Frequency: 60 Hz
  • Line Voltage: 120 V
  • Logistics Code S: 9.13701E+11
  • Max Dist Ball To Lamp Remote: 15'
  • Nom Certificate: No
  • Nominal Open Circuit Voltage: 230 V
  • Number Of Lamps: 1 piece
  • Open Circ Voltage Test Volts: 205-255 V
  • Pieces Per Sku: 1
  • Power Factor: 0.9
  • Product Number: 71A5005500DP
  • Rated Lamp Watts: 35/39W
  • Recommended Fuse: 3:00 AM
  • Rohs Compliant: Yes
  • Saso Certificate: No
  • Secondary Shortcircuit Current: 0.6-0.75 A
  • Sequenceid: 477
  • Short Product Name: MH BAL 35/39W M130 120V C&C
  • Skus Case: 12
  • Stack Height C2: 0.83 in
  • Suitable For Outdoor Use: Yes
  • Temperature Marking: A
  • Ul Insulation Class: H(180�C)
  • Ul Listed: No
  • Ul Recognized: Yes
  • Ul Temperature Code: 1029A
  • Unspsc: 39101902
  • Vde Certificate: No
  • Width B1: 2.2 in
  • Wire Length By Color: 12"
  • Wire Striplength: 0.5 mm
  • Wire Type: Stranded

Installation & Operation

  1. Mount the ballast in a suitable location with appropriate clearance and access for connections and service.
  2. Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
  3. Wire the metal halide lamp according to the M130 ANSI specifications and 35/39W capacity requirements.
  4. Configure remote wiring if needed, maintaining maximum 15-foot distance between ballast and lamp.
  5. Test ignition and operational functionality, verifying proper lamp startup and stable operation.
  6. Complete final inspection and follow ongoing maintenance practices appropriate to magnetic HID ballasts.

Professional Applications

  • Commercial and Industrial Lighting Systems
  • Outdoor Area and Security Lighting
  • Warehouse and Manufacturing Facilities
  • Retail and Display Lighting
  • Parking Structure Illumination
  • Sports and Recreation Facilities
  • Municipal and Street Lighting Projects

Why Choose Philips Lighting Quality?

Philips Lighting delivers proven magnetic ballast technology with UL Recognized components and CSA certification for reliable metal halide lamp operation. The Class H insulation rating and outdoor suitability ensure long-term performance in demanding applications, while RoHS compliance demonstrates environmental responsibility and regulatory adherence.

Manufacturer Resources

Product Specs

Allowed Wiring Config Remote :
Yes
Ansi Code:
M130
Approbation Marks:
ULR, CSA, RoHS
Automatic Restart:
No
Ballast Factor:
1 -
Ballast Type:
Magnetic HID
Bar Code On Case:
5.07811E+13
Bar Code On Pack:
7.81087E+11
Base Model:
71A5005P
Brandlabel:
PHILIPS ADVANCE
Capacitor Catalog Number:
7C280M12RA
Capacitor Dia Oval Dim:
1.65 in
Capacitor Height:
2.75 in
Capacitor Requirements:
120V
Capacitor Temp Rating:
105°C
Capacitor Value F :
28 MFD
Catalog:
71A5005500DP
Ccc Certificate:
No
Ce Marking:
No
Cec Listing:
No
Chia Quality Certificate:
No
Circuit Type:
HX-HPF
Coil Depth C1:
1.7 in
Constant Wattage Deviation:
10%
Csa Certificate:
Yes
Cul Certificate:
No
Eisa:
No
Eop Net Weight Pp:
1.166 kg
Etl Certificate:
No
Family Name:
Core & Coil MH
Fide Certificate:
No
Full Product Name:
MH BAL 35/39W M130 120V C&C
Gtin:
7.81087E+11
Hipot Test 1 Minute :
2000 V
Hipot Test 2 Seconds :
2500 V
Idwindex:
7583614
Idwitemctrl:
7.81087E+11
Igcc:
3708
Ignitor Catalog Number:
LI533-H4
Ignitor Temp Rating:
105°C
Inp Current Open Circuit :
1.1 A
Input Current Operating :
0.5 A
Input Current Starting :
0.45 A
Input Current Short Circuit:
0.3-0.5 A
Input Power Gear:
55 W
Input Voltage At Lamp Dropout:
100 V
Lamp Type:
35/39W MH
Length A1:
4.2 in
Line Frequency:
60 Hz
Line Voltage:
120 V
Logistics Code S :
9.13701E+11
Max Dist Ball To Lamp Remote :
15'
Nom Certificate:
No
Nominal Open Circuit Voltage:
230 V
Number Of Lamps:
1 piece
Open Circ Voltage Test Volts :
205-255 V
Pieces Per Sku:
1
Power Factor:
0.9
Product Number:
71A5005500DP
Rated Lamp Watts:
35/39W
Recommended Fuse:
3:00 AM
Rohs Compliant:
Yes
Saso Certificate:
No
Secondary Shortcircuit Current:
0.6-0.75 A
Sequenceid:
477
Short Product Name:
MH BAL 35/39W M130 120V C&C
Skus Case:
12
Stack Height C2:
0.83 in
Suitable For Outdoor Use :
Yes
Temperature Marking:
A
Ul Insulation Class:
H(180°C)
Ul Listed:
No
Ul Recognized:
Yes
Ul Temperature Code:
1029A
Unspsc:
39101902
Vde Certificate:
No
Width B1:
2.2 in
Wire Length By Color:
12"
Wire Striplength:
0.5 mm
Wire Type:
Stranded
Product Core Size:
2 X 4
Product Type:
HID Ballast
Department:
Electrical
Product Subgroup:
Lamps & Ballasts

Philips Lighting 71A5005500DP – Frequently Asked Questions

1) Will the Philips Advance 71A5005500DP ballast run my 39W metal halide lamp?
It runs 35W and 39W metal halide lamps carrying the M130 ANSI code, one lamp per ballast. The lamp's ANSI designation is the thing to check, not just the wattage. If the lamp is marked anything other than M130, this core and coil is the wrong ballast for it.
2) Does the 35/39W M130 core and coil ballast come with the capacitor and ignitor, or do I order those separately?
The kit is supplied as a complete magnetic HID assembly with capacitor and ignitor included. The capacitor is catalog 7C280M12RA, 28 MFD rated at 120V, and the ignitor is LI533-H4. Both components are rated to 105 degrees C. Order quantity is one piece per SKU.
3) Can I mount this HID ballast away from the fixture and run the leads to the lamp?
Remote mounting is allowed, up to 15 feet between the ballast and the lamp. Beyond that the starting pulse from the ignitor degrades and you risk no-strike or hard-start conditions. Factory leads are 12 inch stranded wire, so any distance past that is field wiring you provide.
4) Will this core and coil ballast fit inside my existing fixture housing?
The core and coil measures 4.2 inches long by 2.2 inches wide, with a coil depth of 1.7 inches and a stack height of 0.83 inches on a 2 x 4 core. Budget separate space for the capacitor, which is 1.65 inches across the oval and 2.75 inches tall. Net weight is 1.166 kg.
5) Is the 35/39W M130 ballast rated for an outdoor parking lot or wall pack fixture?
Yes, it is rated suitable for outdoor use with a Type A temperature marking and Class H insulation good to 180 degrees C. That covers exterior wall packs, area and security lighting where the ballast sits in a weather-protected fixture housing.
6) Is the Philips Advance 71A5005500DP UL Listed or UL Recognized?
UL Recognized, not UL Listed. That is normal for a core and coil component ballast: it carries the Recognized mark because it is intended to be built into a luminaire that is itself listed as an assembly. It is also CSA certified and RoHS compliant.
7) Will this metal halide ballast restrike the lamp automatically after a power blip?
No. Automatic restart is not a feature of this ballast, so after an interruption the lamp has to cool before it will re-strike, the usual several-minute delay with metal halide. If the space needs immediate light on power return, pair the fixture with a separate quartz restrike or emergency source.
8) I have a fixture with an Advance 71A5005P ballast in it. Is this the same part?
The 71A5005500DP is the ordering catalog number built on the 71A5005P base model, from the Philips Advance Core & Coil MH family. Same core and coil design for a 35/39W M130 lamp on 120V. Bulk buyers should note the standard case quantity is 12.
9) What is the power factor and circuit type on this 120V metal halide ballast?
It is an HX-HPF (high reactance, high power factor) circuit with a 0.9 power factor and a ballast factor of 1. Constant wattage deviation is held to 10 percent, so lamp output stays consistent through normal line voltage swings. The lamp drops out if line voltage falls to 100V.
10) What are the starting and open circuit numbers I need for sizing the circuit on this HID ballast?
Nominal open circuit voltage is 230V, tested in a 205 to 255V band. Open circuit input current runs 1.1A, starting current 0.45A, and short circuit input current 0.3 to 0.5A, with secondary short circuit current of 0.6 to 0.75A. Hipot withstand is 2000V for one minute, 2500V for two seconds.
How fast can I get the Philips Lighting 71A5005500DP delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Philips Lighting 71A5005500DP come with a warranty?
Absolutely. The Philips Lighting 71A5005500DP is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Philips Lighting 71A5005500DP?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Philips Lighting 71A5005500DP from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.