Dortronics 6510/COV Anti-Tampe...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$170.00
$112.65

Dortronics 6510/COV Anti-Tamper Alarm Cover for 6500 Series Pull Stations and 5000 Series Push Buttons

(No reviews yet) Write a Review

Model: 6510/COV

In Stock (leaves warehouse same day if ordered before 3pm ET)

$170.00
$112.65
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Dortronics 6510/COV Anti-Tamper Alarm Cover for 6500 Series Pull Stations and 5000 Series Push Buttons

Protect Door Release hardware

These versatile covers offer excellent protection against physical damage (both accidental and intentional This unique device will protect door opening devices without restricting emergency egress. When used with the 6510-S35 Emergency Pull Station these covers are ideal for installation in schools, hospitals, nursing homes, stores, hotels and public buildings of almost every kind.

Utilize with various devices

Perfect for protecting shutdown switches in computer rooms and workshops as well as shielding emergency push buttons; keypads and card readers. Guards against vandalism, accidental damage, dust and grime as well as severe environments inside and outside. With optional weather gaskets the 6510/COV dramatically extends the lifespan of devices in washdown or saltwater applications.

Heavy Duty Construction

The 6510/COV Anti-tamper Alarm Cover consists of a clear, super tough polycarbonate shield and frame that fits over the 6510-S35 Emergency Pull Station. To utilize the 6510/COV; lift the clear plastic cover to gain access to the pull handle on the 6510 pull station for door release, or alarm activation.

Emergency Pull Station Operation

When the 6510-S35 pull station handle is activated, locks are released through a SPDT switch. A second independent set of SPDT contacts is also simultaneously switched to allow communication with an alarm monitoring station such as a card access system, or remote Annunciator panel.

Resources

6510-COV REV-12-1-15_6510-COV CUTSHEET

 

Product Specs

Product Group:
Electronic Access Controls
Series:
6510/COV Series
Product Subgroup:
Parts and Accessories
Subcategory:
Alarm Covers
Commercial/Residential:
Commercial
Electronic:
Yes
Product Type:
Parts and Accessories
Product Model:
6510/COV, 6510/COV/S, 6510/COV/SR
Product Dimension:
4-7/8" W x 5-1/2" H x 2-1/2" D
Product Category:
Electronic Access Controls
Department:
Door Hardware

Dortronics 6510/COV – Frequently Asked Questions

1) Does the alarm cover block emergency egress or lock out the pull station?
No. The clear cover lifts to reach the pull handle underneath, so the pull station stays usable for door release or alarm activation. It guards against vandalism, accidental impact, dust and grime without restricting emergency egress.
2) What is the difference between the 6510/COV, 6510/COV/S and 6510/COV/SR?
Three build levels. The plain 6510/COV is the cover only, a shield with no electronics. The /S adds a piezo alarm sounder that annunciates locally when the cover is lifted. The /SR adds that piezo sounder plus an SPDT relay output, so the lift event can also be reported to a panel or access control system. Pick /SR when you need the tamper signal off the door, not just an audible at the wall.
3) If I already have the 6510 pull station wired to my access control system, does the cover change the wiring?
The pull station's own switching is unaffected. On the 6510-S35, pulling the handle releases locks through an SPDT switch and a second independent set of SPDT contacts switches at the same time for reporting to a card access system or remote annunciator. The cover sits over it. Only the /SR version adds wiring of its own, an SPDT relay output for the tamper signal, plus power for its piezo sounder.
4) Is the 6510/COV a shield only, or does it come with the pull station?
Cover only. The 6510/COV is an accessory consisting of the clear polycarbonate shield and its frame; the 6510-S35 Emergency Pull Station or the 5000 Series push button it protects is ordered separately. Budget for both if you are building a new emergency release point.
5) If I only need an audible deterrent at the door and not a protective shield, what should I use instead of the Dortronics 6510/COV?
The 6510/COV is a clear polycarbonate shield and frame that fits over a 6510-S35 Emergency Pull Station, guarding it against physical damage, vandalism, dust and grime while still allowing egress. If the goal is purely sound, a standalone sounder covers it without adding a shield: the RCI 914 Series is a delayed egress sounder with field-selectable volume output up to 102dB, and the Adams Rite 29-0218 is a piezo electric horn with multi-voltage compatibility. Use one of those when you want noise only; use the 6510/COV when the device itself needs physical protection, and choose the variant with the piezo alarm sounder if you want both in one part.
6) I need a dry contact back to my access control panel from the door release point. Is the Dortronics 6510/COV cover the right way to get that, or is a switch kit better?
The 6510/COV is offered in a cover-only version, a version with a piezo alarm sounder, and a version with a piezo sounder plus an SPDT relay output. The SPDT relay version is what gives you a contact from the cover itself when it is lifted. If instead you want the signal to come from the exit device or lock, that is a different part: Command Access offers field installable request to exit kits such as the CRSREXKIT-ED for Cal Royal 22/98 and Sargent 80 Series exit devices with an SPDT switch, the CYREXKIT-ED for Corbin 5000 and Yale 7000 exit devices rated 5A, and the REX-KIT-ML for ML1-Series mortise locks. The cover signals that someone opened the shield; the REX kits signal that the hardware was operated.
7) Can I use the 6510/COV outdoors or in a washdown area?
Yes, with the optional weather gaskets. The cover shields the device from dust, grime and severe environments inside and out, and Dortronics states that with weather gaskets it extends device life in washdown or saltwater applications. The gaskets are an add-on, so specify them separately if the opening is exposed.
8) Where do these anti-tamper covers typically get installed?
Schools, hospitals, nursing homes, stores, hotels and public buildings, paired with the 6510-S35 Emergency Pull Station. They also work for shielding shutdown switches in computer rooms and workshops, and for protecting emergency push buttons, keypads and card readers from nuisance hits. It is a commercial-duty product, not a residential one.
9) For a door where I want to slow down unauthorized exits rather than just cover the release button, what are my options besides the Dortronics 6510/COV?
The 6510/COV protects a door opening device without restricting emergency egress, so it deters tampering but does not delay anyone. If the requirement is to actually resist or delay an exit, look at delayed egress hardware instead: the RCI 914 Series is a delayed egress sounder, and the Securitron SB-MXD is an exit delay sex bolt. Those address the delay function. The 6510/COV is the right answer when egress must stay immediate and you only need the release device shielded.
10) Does the Dortronics 6510/COV include a power supply or relay board for the alarm, or do I need to add those?
The 6510/COV models are 6510/COV, 6510/COV/S and 6510/COV/SR, and what varies between them is the cover function: cover only, cover with piezo alarm sounder, and cover with piezo sounder plus SPDT relay output. Power and downstream switching are separate items. Adams Rite offers the 4605 transformer, 115 VAC to 12/24 VAC with a 40 volt-amp output, for low voltage power, and the Locknetics RDB4 is a four-output relay distribution board if you need to fan one input out to several controlled devices.
11) Will a rain guard like the HES 1000-102 do the same job as this cover?
No, different part for a different device. The HES 1000-102 is a Grade 1 rain guard for 1006 Series electric strikes, protecting a strike in the frame from rain or high dust. The Dortronics 6510/COV protects a wall-mounted pull station or push button from tampering and impact, and only the /S and /SR versions alarm when opened.
12) I am specifying release hardware for an all-glass entrance. Does the Dortronics 6510/COV work there?
The 6510/COV is a wall or surface mounted shield sized 4-7/8 inch by 5-1/2 inch by 2-1/2 inch that fits over 6500 Series pull stations and 5000 Series push buttons, so it needs a flat mounting surface behind the protected device rather than a glass leaf. For glass door openings, Securitron offers a Glass Door Accessories line, listed at Grade 2, intended for that construction. Mount the 6510/COV on the adjacent wall over the release station and use the glass door accessories on the leaf itself.
How fast can I get the Dortronics 6510/COV delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Dortronics 6510/COV come with a warranty?
Absolutely. The Dortronics 6510/COV is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Dortronics 6510/COV?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Dortronics 6510/COV from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.