Eaton CL Ground Fault Circuit Breaker 15A 120/240V Single-Pole GFCI with 10 kAIC Interrupt Rating
Professional Ground Fault Protection for Residential & Commercial Applications
The Eaton CL Ground Fault Circuit Breaker delivers reliable ground fault circuit interruption with 15A trip rating and 120/240V voltage compatibility. This single-pole GFCI breaker features plug-on connection design with 10 kAIC interrupt rating and trip-to-center functionality for enhanced safety and performance in electrical panel installations.
Professional Features & Benefits
- 15A Trip Rating: Provides precise overcurrent protection for branch circuits while maintaining reliable operation under normal load conditions.
- Ground Fault Circuit Interrupter: Delivers essential GFCI protection to prevent electrical shock hazards in wet locations and sensitive applications.
- 10 kAIC Interrupt Rating: Ensures safe fault current interruption capability for residential and light commercial electrical systems.
- Single-Pole Design: Compact 1-inch width maximizes panel space utilization while providing dedicated circuit protection.
- Plug-On Connection: Simplifies installation with secure mechanical and electrical connection to panel bus bars.
- Trip-to-Center Functionality: Provides clear visual indication of tripped condition for faster troubleshooting and system restoration.
- 120/240V Voltage Rating: Compatible with standard residential and commercial voltage systems for versatile application flexibility.
Technical Specifications
- Certifications: Contact Manufacturer
- Circuit Protection: Ground fault circuit interrupter
- Connection: Plug-on
- Indicators: GFI
- Interrupt Rating: 10 kAIC
- Main Circuit Breaker: CLGF
- Mounting Method: Plug-on
- Number Of Poles: Single-pole
- Product Details: Ground fault circuit breaker
- Product Height: 1 in
- Product Length Depth: 4 in
- Product Weight: .45 lb
- Product Width: 3.5 in
- Trip Rating: 15 A
- Trip Type: Trip-to-center
- Voltage Rating: 120/240 V
- Wire Size: #14-8 AWG
Installation & Operation
- Mount the unit in a suitable location with appropriate clearance and access for connections and service.
- Connect utility and load conductors following applicable guidelines and the manufacturer's instructions.
- Wire generator or power input according to the provided voltage/phase specifications and compatible capacity.
- Configure any available load management or control features as supported by the provided specifications.
- Test automatic transfer or operational functionality and verify proper performance before placing into service.
- Complete final inspection and follow ongoing maintenance practices appropriate to the product category.
Professional Applications
- Residential Kitchen and Bathroom Circuits
- Commercial Wet Location Protection
- Outdoor Electrical Installations
- Pool and Spa Equipment Circuits
- Workshop and Garage Applications
- Medical and Healthcare Facilities
- Educational Institution Safety Systems
Why Choose Eaton Quality?
Eaton CL Ground Fault Circuit Breakers provide dependable electrical protection with proven plug-on connection technology and compact single-pole design. The 10 kAIC interrupt rating and trip-to-center operation ensure reliable performance and clear fault indication for professional electrical installations requiring ground fault protection.
Manufacturer Resources
Product Specs
- Certifications:
- Contact Manufacturer
- Circuit Protection:
- Ground fault circuit interrupter
- Connection:
- Plug-on
- Indicators:
- GFI
- Interrupt Rating:
- 10 kAIC
- Main Circuit Breaker:
- CLGF
- Mounting Method:
- Plug-on
- Number Of Poles:
- Single-pole
- Product Details:
- Ground fault circuit breaker
- Product Height:
- 1 in
- Product Length Depth:
- 4 in
- Product Weight:
- .45 lb
- Product Width:
- 3.5 in
- Trip Rating:
- 15 A
- Trip Type:
- Trip-to-center
- Voltage Rating:
- 120/240 V
- Wire Size:
- #14-8 AWG
- Department:
- Electrical
- Product Group:
- Circuit Breakers
- Product Type:
- Circuit Breaker