Hoffman A364214BGECT NEMA 3R V...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,051.40

Hoffman A364214BGECT NEMA 3R Vented Double Door Current Transformer Cabinet

(No reviews yet) Write a Review

Model: A364214BGECT

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,051.40
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Hoffman A364214BGECT NEMA 3R Vented Double Door Current Transformer Cabinet, 36-Inch x 42-Inch x 14-Inch

The Hoffman A364214BGECT is a NEMA 3R vented double door current transformer cabinet engineered to house metering and current transformer equipment in outdoor and rainy-condition electrical installations. Sized at 36-Inch x 42-Inch x 14-Inch, this cabinet provides ample interior space for current transformer components while its NEMA 3R rating protects internal equipment from rain, sleet, and outdoor exposure. The vented double door design supports airflow to help manage heat buildup around energized components, while providing convenient dual-door access for installation, metering, and service work. Built to the demanding standards electrical contractors and utility crews expect from Hoffman enclosures, this cabinet is a dependable solution for current transformer housing applications.

Key Features

  • Cabinet Dimensions: 36-Inch x 42-Inch x 14-Inch enclosure sized to accommodate current transformer equipment and associated wiring.
  • NEMA 3R Rating: Rated for outdoor use, protecting internal components from rain, sleet, and falling dirt.
  • Vented Construction: Vented panel design promotes airflow to help dissipate heat generated by current transformer equipment.
  • Double Door Access: Dual-door configuration allows for convenient access to internal components during installation, inspection, and metering activities.
  • Current Transformer Application: Purpose-built enclosure category designed specifically to house current transformer equipment for utility and commercial metering setups.
  • Durable Enclosure Construction: Constructed to withstand outdoor environmental exposure while safeguarding sensitive metering equipment inside.

Certifications & Compliance

  • NEMA 3R Rated for Outdoor Use

Technical Specifications

  • Product Type: Current Transformer Cabinet
  • Dimensions: 36-Inch x 42-Inch x 14-Inch
  • Door Configuration: Vented Double Door
  • Enclosure Rating: NEMA 3R

Typical Applications

  • Utility Metering and Current Transformer Housing
  • Outdoor Electrical Service Equipment Enclosures
  • Commercial and Industrial Metering Installations
  • Outdoor and Wet-Location Installations
  • New Construction and Service Upgrades

Why Hoffman?

Hoffman enclosures are trusted by electrical professionals for dependable protection of sensitive equipment in demanding outdoor environments. The A364214BGECT's NEMA 3R rating and vented double door design deliver a practical, accessible solution for current transformer housing needs, supporting reliable, code-compliant performance for utility and commercial metering installations.

Manufacturer Resources

Product Specs

list_batch:
HOF-20260924
Product Type:
Current Transformer Cabinet
Configuration:
Vented Double Door
Standards:
NEMA 3R
Department:
Electrical
Product Subgroup:
NEMA 3R Enclosures
Product Material:
Steel

Hoffman A364214BGECT – Frequently Asked Questions

1) Can a Hoffman A364214BGECT CT cabinet be mounted outdoors on an exterior wall?
Yes. The A364214BGECT carries a NEMA 3R rating, which covers outdoor use against rain, sleet, and falling dirt, so it is suited to exterior wall installations at a service entrance or meter location. NEMA 3R is not a washdown or dust-tight rating, so if the site involves hosing, heavy windblown dust, or submersion, you need a higher rated enclosure instead.
2) What size current transformer cabinet is the Hoffman A364214BGECT, and will it clear a 14 inch wall cavity?
It measures 36 x 42 x 14 inches. The 14 inch figure is the cabinet depth, so plan for that much projection off the mounting surface plus room for the doors to swing. The 36 x 42 face is what has to fit between studs or conduit runs on the wall.
3) Is the Hoffman A364214BGECT the right enclosure for a utility metering CT installation?
Yes, that is what it is built for. It is a current transformer cabinet intended to house CTs, metering equipment, and the associated wiring for utility and commercial metering setups, in outdoor service entrance and service upgrade work. Utilities often have their own approval list and sealing requirements for CT cabinets, so match the cabinet to the serving utility's metering spec before you set it.
4) Why would I choose a vented CT cabinet instead of a sealed enclosure?
Vented panels let air move through the cabinet so heat coming off energized CT and metering components can escape rather than build up inside. That is the trade off: the A364214BGECT is vented, which helps thermally but means the enclosure is not sealed against dust or water spray beyond what NEMA 3R covers. For a clean indoor metering closet where dust control matters more than heat, a non-vented NEMA 1 or 12 enclosure is the better pick.
5) What is the Hoffman A364214BGECT made of?
Steel construction. For an outdoor meter or CT installation that means you get the mechanical strength utilities expect, and you should keep the finish intact, touch up any field-drilled holes or scratches, and use listed weatherproof fittings at every penetration so moisture does not track in.
6) Does the double door design on this Hoffman CT cabinet make service access easier than a single door?
It does. The A364214BGECT is a vented double door configuration, so the full 36 x 42 inch opening is exposed across two leaves rather than one wide swinging door. That matters on a tight meter bank or in an alley where a single 36 inch door would not have clearance to open, and it gives a crew working CT leads and test switches access from both sides of the opening.
7) What is the exact Hoffman part number to order for this 36 x 42 x 14 CT cabinet?
Order it as Hoffman A364214BGECT. That single manufacturer part number covers the 36 x 42 x 14 inch NEMA 3R vented double door current transformer cabinet, and there is only one configuration under it, so there is no size or finish option to specify separately.
How fast can I get the Hoffman A364214BGECT delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Hoffman A364214BGECT come with a warranty?
Absolutely. The Hoffman A364214BGECT is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Hoffman A364214BGECT?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Hoffman A364214BGECT from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.