Milbank 200A 3-Phase Ringless ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$805.36

Milbank 200A 3-Phase Ringless Meter Socket with Lever Bypass - 7 Terminal Surface Mount

(No reviews yet) Write a Review

Model: U9701-O

In Stock (leaves warehouse same day if ordered before 3pm ET)

$805.36
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Milbank 200A 3-Phase Ringless Meter Socket with Lever Bypass - 7 Terminal Surface Mount

Professional electrical metering solution with integrated bypass functionality

The Milbank 200A 3-Phase Ringless Meter Socket delivers reliable electrical metering with integrated lever bypass capability for professional installations. Featuring a robust G90 galvanized steel construction with powder coat finish and Type 3R rating, this surface-mount meter socket accommodates both overhead and underground cable entry with 6 AWG to 350 kcmil wire capacity on both line and load sides.

Professional Features & Benefits

  • 200 Continuous Ampere Rating: Provides substantial capacity for commercial and industrial electrical service applications requiring reliable high-amperage metering.
  • Lever Bypass Provision: Enables safe meter maintenance and replacement without service interruption, reducing downtime and operational disruption.
  • 7 Terminal Configuration: Accommodates 3-phase electrical systems with proper neutral and grounding connections for comprehensive power distribution.
  • Type 3R Enclosure Rating: Weather-resistant construction suitable for outdoor installations with protection against rain, sleet, and ice formation.
  • G90 Galvanized Steel with Powder Coat: Corrosion-resistant materials ensure long-term durability and reliable performance in demanding environmental conditions.
  • Flexible Cable Entry: Supports both overhead and underground service connections, providing installation versatility for various site requirements.
  • UL Listed Certification: Meets rigorous safety and performance standards for professional electrical installations and code compliance.

Technical Specifications

  • Amperage Rating: 200 Continuous Ampere
  • Application: Meter Socket
  • Brand Name: Milbank
  • Bypass Provision: Lever Bypass
  • Cable Entry: Overhead or Underground
  • Departent: Electrical
  • Frequency Rating: 60 Hertz
  • Insulation: Glass Polyester
  • Line Side Wire Range: 6 AWG - 350 kcmil
  • Load Side Wire Range: 6 AWG - 350 kcmil
  • Main Breaker Size: No Main Breaker
  • Number Of Jaws: 7 Terminal
  • Number Of Main Breakers: 0
  • Number Of Meter Positions: 1 Position
  • Number Of Receptacles: 0
  • Phase: 3 Phase
  • Product Family Code: HD7T
  • Product Height: 19 IN
  • Product Material: G90 Galvanized Steel with Powder Coat Finish
  • Product Mounting: Surface Mount
  • Product Type: Ringless Meter Socket
  • Standard: UL Listed;Type 3R
  • Terminal: Lay in
  • Unspsc Number: 39121102
  • Voltage Rating: 600 Volts Alternating Current
  • Width: 13 IN

Professional Applications

  • Commercial Building Electrical Service
  • Industrial Facility Power Distribution
  • Multi-Tenant Properties
  • Retail and Office Buildings
  • Manufacturing Facilities
  • Institutional Buildings
  • Municipal and Government Facilities

Why Choose Milbank Quality?

Milbank delivers proven reliability through UL Listed certification and Type 3R weather-resistant construction. The robust G90 galvanized steel with powder coat finish ensures long-term performance, while the comprehensive 7-terminal configuration and flexible cable entry options provide professional-grade versatility for demanding electrical service applications.

Manufacturer Resources

Product Specs

Amperage Rating:
200 Continuous Ampere
Application:
Meter Socket
Brand Name:
Milbank
Bypass Provision:
Lever Bypass
Cable Entry:
Overhead or Underground
Frequency Rating:
60 Hertz
Insulation:
Glass Polyester
Line Side Wire Range:
6 AWG - 350 kcmil
Load Side Wire Range:
6 AWG - 350 kcmil
Main Breaker Size:
No Main Breaker
Number Of Jaws:
7 Terminal
Number Of Main Breakers:
0
Number Of Meter Positions:
1 Position
Number Of Receptacles:
0
Phase:
3 Phase
Product Family Code:
HD7T
Product Height:
19 IN
Product Type:
Ringless Meter Socket
Standards:
UL Listed;Type 3R
Terminal:
Lay in
Unspsc Number:
39121102
Voltage Rating:
600 Volts Alternating Current
Product Material:
G90 Galvanized Steel with Powder Coat Finish
Product Mounting:
Surface Mount
Amps:
200
Product Width:
13 IN
Department:
Electrical
Product Subgroup:
Electrical
Insulation Type:
Glass Polyester
Installation Category:
Surface Mount
Terminal Type:
Lay In
Number of Phases:
3
Product Details:
Ringless Meter Socket
Frequency:
60 hertz
Number of Terminations:
7
Product Group:
Metering & Service Entrance

Milbank U9701-O – Frequently Asked Questions

1) Will a Milbank U9701 7-terminal socket work on a 3-phase 4-wire 120/208V service?
The U9701 is a 7-jaw, 3-phase ringless meter socket rated 600 volts AC at 60 Hz, so it covers 120/208V and 277/480V three-phase four-wire services within that 600V ceiling. Seven jaws is the standard 3-phase 4-wire configuration. If your service is single phase, this is the wrong socket, you want a 4-jaw or 5-jaw unit instead.
2) What size conductors can I land in a Milbank 200A meter socket?
Both line and load terminals take 6 AWG through 350 kcmil, and they are lay-in type, so you drop the conductor in rather than fishing it through a closed lug. Continuous rating is 200 amps. That range covers the usual 4/0 aluminum or 3/0 copper on a 200A service with room to spare if the engineer has upsized for voltage drop.
3) Does the Milbank U9701 meter socket come with a main breaker or disconnect?
No breaker. The U9701 is a meter socket only, no main breaker and no receptacles, with one meter position. You need a separate service disconnect downstream (or ahead of it, depending on how your utility and the AHJ want the service arranged). If you want metering and the main in one enclosure, look for a meter main combination instead.
4) What is the difference between the hub and closing plate options on the Milbank U9701?
The suffix tells you how the top of the can is configured for service entry. U9701-O is a plain top. The -R is a large hub for overhead conduit, and -RRL is a large hub that converts down to a small hub. The -X carries a large closing plate and -XL a small closing plate, both for underground feeds where you enter from the bottom. -RXL is large hub open, adapting to a small closing plate. Pick the hub versions when the service drops overhead into the top of the socket, and the closing plate versions when the lateral comes up from below.
5) My utility requires an approved meter socket. Are there utility-specific versions of the Milbank U9701?
Several versions are built to specific utility approvals: U9701-RXL-ALT is Alliant Energy approved, U9701-RXL-QG-AMS is Ameren approved, U9701-RXL-SMECO is SMECO approved, and U9701-X-QG-BLG-AEP is AEP approved. Utilities publish an accepted equipment list and will reject a socket that is not on it, so order the suffix your serving utility names rather than the generic one.
6) Which Milbank U9701 has a barrel lock provision for the utility seal?
Two barrel lock sizes are offered. U9701-RRL-BL takes a 9/16 inch barrel lock and U9701-RRL-BLG takes a 7/8 inch barrel lock, both on the large hub open adapting to small hub open configuration. U9701-X-QG-BLG-AEP also carries the 7/8 inch barrel lock provision. If your utility uses a padlock and hasp rather than a barrel lock, U9701-X-QG-HSP has a stainless steel hasp, and U9701-RL-IL is the small hub version with a lock provision. Barrel lock diameter is not interchangeable, so confirm which one the utility uses on your territory before ordering.
7) Can I pull the meter on a Milbank U9701 without killing power to the building?
Yes, that is what the lever bypass is for. The U9701 has a lever bypass provision, so a utility tech or electrician can shunt the jaws and swap or test the meter while the load stays energized. A socket without bypass means the tenant goes dark for the swap. On a commercial or multi-tenant building where an outage is a service call in itself, the bypass version is what you want.
8) Is the Milbank U9701 meter socket rated for outdoor mounting on an exterior wall?
Type 3R and UL Listed, so it is built for outdoor wall mounting with protection against rain, sleet and ice. It is a surface mount enclosure in G90 galvanized steel with a powder coat finish. Type 3R is not a washdown or dusttight rating, so for a corrosive or hosed-down environment you would specify a different enclosure type.
9) How much wall space do I need for a Milbank U9701 meter socket?
The enclosure measures 19 inches high by 13 inches wide. Add clearance above for the hub or conduit entry on the -R and -RRL versions, and below for the closing plate versions where the lateral comes up. It surface mounts, so nothing is recessed into the wall.
10) What is a ringless meter socket and does my utility allow one?
Ringless means the meter is retained by a hinged cover over the meter rather than by a sealing ring clamped around the rim. The U9701 is the ringless configuration. Utilities are split on this: some territories specify ringless, others require ring type, and they will not energize the wrong one. Check your utility's service requirements before you buy, since the socket body itself is not field convertible between the two styles.
11) What does the quadplex ground option on the Milbank U9701 add?
Quadplex ground gives you a four-position ground and neutral connection point inside the can. It shows up on U9701-RXL-QG, U9701-RXL-QG-AMS, U9701-RXL-SMECO, U9701-X-QG-BLG-AEP and U9701-X-QG-HSP. Order one of those when the utility or the AHJ wants the grounding electrode conductor and neutral landed in the socket rather than downstream.
12) I need two conduit knockouts in the top of the meter socket. Is there a version for that?
U9701-RXL-TKO is the twin knockout version, large hub open adapting to a small closing plate. Use it where two raceways have to enter the same socket. The standard hub versions give you a single entry.
13) What insulates the jaws in a Milbank U9701 meter socket?
Glass polyester carries the jaws in the U9701. It holds up to the heat cycling a 200 amp continuous service puts through the socket and does not track the way a lesser insulator can when the can sees moisture at 600 volts.
How fast can I get the Milbank U9701-O delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Milbank U9701-O come with a warranty?
Absolutely. The Milbank U9701-O is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Milbank U9701-O?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Milbank U9701-O from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.