Milbank F-Frame Circuit Breake...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$696.75

Milbank F-Frame Circuit Breaker 200 Amp 2-Pole 240V Thermal Magnetic with Bolt-On Connection

(No reviews yet) Write a Review

Model: UQFB-M-150
$696.75

In Stock (leaves warehouse same day if ordered before 3pm ET)

$696.75
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Milbank F-Frame Circuit Breaker 200 Amp 2-Pole 240V Thermal Magnetic with Bolt-On Connection

Professional Current Interrupting Device for Metering Applications

The Milbank F-Frame Circuit Breaker delivers reliable 200 amp current interruption with thermal magnetic trip protection for single phase 240V applications. This bolt-on circuit breaker features F-Frame construction with non-metallic housing and lever actuator operation, providing dependable performance for metering accessory applications with 10,000 AIC and 22,000 AIC ratings.

Professional Features & Benefits

  • 200 Amp F-Frame Design: Provides robust current handling capacity with reliable F-Frame construction for demanding electrical applications.
  • Thermal Magnetic Trip Protection: Delivers precise overcurrent protection combining thermal and magnetic trip mechanisms for comprehensive circuit safety.
  • 240V Single Phase Rating: Optimized for residential and light commercial single phase electrical systems with standard voltage compatibility.
  • Bolt-On Connection System: Ensures secure lug-to-lug connections with reliable mechanical attachment for professional installations.
  • UL Listed Certification: Meets rigorous safety and performance standards ensuring code compliance and professional reliability.
  • Non-Metallic Construction: Provides corrosion resistance and electrical isolation with durable housing materials.
  • Lever Actuator Operation: Enables easy manual operation and clear on/off indication for maintenance and service applications.

Technical Specifications

  • Actuator: Lever
  • Application: Metering Accessory
  • Auxiliary Contacts: No Auxiliary Contacts
  • Brand Name: Milbank
  • Connection: Lug to Lug
  • Departent: Electrical
  • Frame: F-Frame
  • Frequency Rating: 60 Hertz
  • Number Of Poles: 2
  • Operating Temperature: 40 Degrees Celsius
  • Phase: 1 Phase
  • Product Family Code: MSCB
  • Product Height: 7.438 IN
  • Product Length: 3.281 IN
  • Product Material: Non Metallic
  • Product Type: Current Interrupting Device
  • Standard: UL Listed
  • Trip Type: Thermal Magnetic
  • Unspsc Number: 39121601
  • Voltage Rating: 240 Volts Alternating Current
  • Width: 3 IN

Professional Applications

  • Residential Service Panel Protection
  • Commercial Metering Applications
  • Light Industrial Electrical Systems
  • Multi-Unit Property Electrical Distribution
  • Professional Office Building Power Systems
  • Retail Establishment Electrical Protection
  • Emergency Service Facility Power Distribution

Why Choose Milbank Quality?

Milbank circuit breakers deliver proven reliability with UL Listed certification and professional-grade F-Frame construction. The non-metallic housing provides long-term durability while thermal magnetic trip protection ensures precise overcurrent response for safe, dependable electrical system protection.

Manufacturer Resources

Product Specs

Actuator:
Lever
Application:
Metering Accessory
Auxiliary Contacts:
No Auxiliary Contacts
Brand Name:
Milbank
Connection:
Lug to Lug
Frame:
F-Frame
Frequency Rating:
60 Hertz
Number Of Poles:
2
Operating Temperature:
40 Degrees Celsius
Phase:
1 Phase
Product Family Code:
MSCB
Product Height:
7.438 IN
Product Length:
3.281 IN
Product Type:
Current Interrupting Device
Standards:
UL Listed
Trip Type:
Thermal Magnetic
Unspsc Number:
39121601
Voltage Rating:
240 Volts Alternating Current
Product Material:
Non Metallic
Product Width:
3 IN
Department:
Electrical
Product Subgroup:
Electrical
Connection Type:
Lug To Lug
Number of Phases:
1
Product Details:
Current Interrupting Device
Frequency:
60 hertz

Milbank UQFB-M-150 – Frequently Asked Questions

1) Will the Milbank UQFB bolt-on breaker work in a 120/240V single phase residential service?
Yes. The UQFB is a two-pole breaker rated 240 volts AC, 1 phase, 60 Hertz, so it lands across both hot legs of a standard single phase service. The two poles are common trip, so a fault on either leg opens both. It is a metering accessory breaker, meaning it goes into Milbank metering equipment rather than a general lighting panel.
2) What amp ratings does the Milbank UQFB F-Frame breaker come in?
Five ratings on the 200 amp F-Frame: 100, 125, 150, 175 and 200 amps. Not every rating exists in every build. The 175 amp is 10K AIC only, and the 22K AIC (UQFBH) versions run 100, 125, 150 and 200. Size the breaker to the service conductors and the meter socket rating, not to the frame.
3) What is the threaded load-side tang option on the Milbank UQFB, and do I need it?
The threaded tang is a load-side terminal that takes a bolted lug or bus connection instead of the standard tang. Order the M suffix versions (UQFB-M-200, UQFBH-M-200) when the equipment or the conductor termination requires that bolted stud. If your Milbank enclosure is set up for the standard connection, the plain UQFB-200 is the one. The tang option is offered at 100, 125, 150 and 200 amps in 10K AIC, and at 100 and 200 amps in 22K AIC.
4) Will the Milbank UQFB breaker fit in my existing meter main enclosure?
The breaker measures 7.438 inches by 3.281 inches by 3 inches, and it mounts bolt-on with lug to lug connections. That is the F-Frame footprint Milbank metering equipment is built around, so it drops into a Milbank enclosure prepped for a 200 amp F-Frame bolt-on. It is not a plug-on load center breaker and will not clip onto a residential panel bus.
5) I am replacing a failed 200 amp breaker in a Milbank meter pack. How do I identify the right replacement?
Read the label on the breaker you are pulling and match three things: the amp rating (100, 125, 150, 175 or 200), the interrupting rating, and whether it has a threaded load-side tang. A plain UQFB-200 is 200 amp at 10,000 AIC with a standard tang. UQFBH-200 is the same breaker at 22,000 AIC. Add the M (UQFB-M-200, UQFBH-M-200) if the existing unit has the threaded stud on the load side. Never drop in a lower AIC than what came out.
6) How does a thermal magnetic breaker like the Milbank UQFB respond to a motor inrush versus a short circuit?
Two trip mechanisms in one breaker. The thermal element uses a bimetal that heats with sustained overload, so it rides through the brief inrush of a motor or compressor start and trips only if the overcurrent persists. The magnetic element responds instantly to the high current of a short circuit or ground fault. That combination is why thermal magnetic is the standard choice on a service disconnect feeding mixed motor and resistive load.
7) Does the Milbank UQFB breaker have auxiliary contacts for a shunt trip or alarm signal?
No auxiliary contacts. The UQFB is a straight mechanical breaker with a lever actuator for manual on/off and trip indication, with no contact block for remote status, shunt trip, or an alarm circuit. If the job needs remote indication or remote tripping, this is not the breaker for it.
8) Can the Milbank UQFB breaker be installed outdoors in a hot climate without derating?
The rating is based on a 40 degree Celsius (104 F) ambient. In a sun-exposed outdoor enclosure the internal air can run well above that, and a thermal magnetic breaker will nuisance trip below its nameplate amps when it does. On hot southern exposures, either shade the enclosure, allow ventilation, or size the service so the breaker is not run near its rating. The housing itself is non-metallic, which helps with corrosion in coastal and wet locations.
9) Can I use the Milbank UQFB two-pole breaker on a three phase 208V service?
No. The UQFB is a two-pole, single phase device rated 240 volts AC. A three phase service disconnect needs a three-pole breaker sized for that system. Use this one only on single phase 240V metering equipment.
How fast can I get the Milbank UQFB-M-150 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Milbank UQFB-M-150 come with a warranty?
Absolutely. The Milbank UQFB-M-150 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Milbank UQFB-M-150?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Milbank UQFB-M-150 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.