PDQ 9910 Electric Strike for 6300 / 6400 Rim Exit Devices
Electric Strikes for PDQ Locks and Rim Exit Devices
An electric strike is a door frame strike with a keeper that releases electrically, so an access control system can unlock the door without changing the lock. The lock stays mechanical, and people inside still leave by turning the lever or pushing the exit device.
PDQ makes three electric strikes, each sized to one kind of latch: the 85001 for PDQ Grade 1 and Grade 2 cylindrical locks, the 85003 for PDQ MR Series mortise locks without a deadbolt, and the 9910 for PDQ 6300 and 6400 rim exit devices. All three come in 630 satin stainless steel.
Key Features
- 85001 and 85003: field changeable from fail secure to fail safe, ship fail secure, 12 to 24 VDC
- 85001 and 85003: factory tested to 1,000,000 cycles; 0.28A at 12 VDC, 0.14A at 24 VDC
- 9910: completely surface mounted on the frame, non-handed, with a spacer for 1/2" to 3/4" latch projection
- 9910: fail secure, 3-hour fire rated, 1,500 lbf static and 70 ft-lb dynamic strength, 250,000 cycles
- 9910: field selectable 12/24 VDC or 12 to 24 VAC, horizontal adjustment up to 1/4", plug-in wire connectors, five year limited warranty
- 630 (US32D) satin stainless steel finish
Technical Specifications
- Manufacturer Part Number: 9910
Available Options
- Finish: 630 - Satin Stainless Steel
Typical Applications
- Office suite entries and interior access controlled doors
- Staff-only doors with MR Series mortise locks
- Entrances and corridor doors with rim exit devices
Frequently Asked Questions
What is the difference between fail safe and fail secure?
A fail secure electric strike stays locked when power is cut, and a fail safe strike unlocks when power is cut. The PDQ 85001 and 85003 are field changeable between the two and ship fail secure. The 9910 is fail secure only.
Can electric strikes be used on fire-rated doors?
Only if the strike is fire rated and fail secure, because a fire door must stay latched during a fire. The PDQ 9910 is 3-hour fire rated and fail secure. The 85001 and 85003 are not listed as fire rated.
Can an electric strike release a deadbolt?
No. A strike cannot release a deadbolt, which is why the 85003 is for MR Series mortise locks without a deadbolt. A mortise lock with a deadbolt needs an electrified lock instead.
Manufacturer Resources
Product Specs
- Department:
- Door Hardware
- Product Group:
- Electrified Hardware
- Product Subgroup:
- Electric Strikes
- Product Type:
- Electric Strike
- Product Category:
- Electrified Hardware
- Product Model:
- 9910
- Commercial/Residential:
- Commercial
- Tags:
- pdq 9910, 9910 pdq, 9910