Philips Lighting 913700500891 ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$257.86
$207.86

Philips Lighting 913700500891 Core & Coil Magnetic HID Ballast, 70W HPS, 120V

(No reviews yet) Write a Review

Model: 913700500891
Selected Model is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$257.86
$207.86
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Philips Lighting 913700500891 Core & Coil Magnetic HID Ballast, 70W HPS, 120V

Philips Lighting 913700500891 is a Core & Coil magnetic HID ballast (base model 71A7907B) engineered to operate a 70W HPS lamp rated per ANSI code S62. Rated 120V at 60 Hz with 86 W nominal input power and a 0.9 nominal power factor on an R-HPF circuit, this ballast is UL Recognized, features a built-in integral ignitor rated to 125°C, and is suitable for outdoor use with remote wiring capability up to a 2' maximum ballast-to-lamp distance.

Key Features

  • Lamp Compatibility: Designed to operate a 70W HPS lamp rated per ANSI code S62 for reliable, code-compliant HID lighting.
  • Electrical Rating: 120V input at 60 Hz, 0.75 A nominal input current, 86 W nominal input power, and a 0.9 nominal power factor on an R-HPF circuit.
  • Core & Coil Construction: Magnetic HID ballast design with constant wattage deviation within trapezoid for stable lamp operation over its life.
  • Integral Ignitor: Built-in INTEGRAL ignitor rated to 125°C for dependable lamp starting without a separate ignitor module.
  • Remote Wiring Capability: Supports remote wiring configurations up to a 2' maximum ballast-to-lamp distance for flexible fixture layouts.
  • Outdoor Rated: Suitable for outdoor installations, supporting use in exterior HID lighting fixtures.
  • UL Insulation Class H (180°C): Rated for elevated operating temperatures common in HID ballast applications.

Certifications & Compliance

  • UL Recognized (ULR)
  • ANSI S62 Lamp Compatibility

Technical Specifications

  • ANSI Code: S62
  • Approval Marks: ULR
  • Automatic Restart: No
  • Ballast Factor (Nom): 1
  • Input Current (Nom): 0.75 A
  • Max Ballast/Lamp Distance (Remote Wiring): 2'
  • Numerator Packs Per Outer Box: 1
  • Numerator Quantity Per Pack: 1
  • Order Product Name: CORE & COIL HID 71A7907001DB
  • Power Factor (Nom): 0.9
  • Remote Wiring Configuration Allowed: Yes
  • Suitable For Outdoor Use: Yes
  • Temperature Marking: A
  • UL Recognized: Yes
  • Wire Length By Color: 12"

Typical Applications

  • HID Fixture Retrofits & Replacements
  • Outdoor Area & Site Lighting
  • Commercial & Industrial HPS Lighting Systems
  • Remote-Mounted Ballast Installations

Why Philips Lighting?

Philips Lighting builds the 913700500891 with Core & Coil magnetic construction and UL Recognized components for dependable, code-compliant HPS lighting performance. With an integral ignitor, a defined UL insulation class rated to 180°C, and remote wiring capability up to 2', this ballast supports reliable operation in outdoor and industrial HID lighting systems.

Manufacturer Resources

Product Specs

Ansi Code:
S62
Approval Marks:
ULR
Automatic Restart:
No
Ballast Factor Nom :
1
Ballast Type:
Magnetic HID
Base Model:
71A7907B
Capacitor Catalog Number:
7C280M12RA
Capacitor Diameter Oval Dimensions:
1.65 in
Capacitor Height:
2.75 in
Capacitor Requirements:
120V
Capacitor Temperature Rating:
105°C
Capacitor Value:
28 MFD
Circuit Type:
R-HPF
Constant Wattage Deviation:
Within Trapezoid
Ean Upc Product:
7.81087E+11
Hipot Test 1 Minute :
2000 V
Hipot Test 2 Seconds :
2500 V
Ignitor Catalog Number:
INTEGRAL
Ignitor Temperature Rating:
125°C
Input Current Nom :
0.75 A A
Input Current Open Circuit :
1.3 A
Input Current Short Circuit :
1.9-2.9 A
Input Current Starting :
0.9 A
Input Frequency:
60 Hz
Input Power Nom :
86 W
Input Voltage:
120 V
Lamp Type:
70W HPS
Material Nr 12nc :
9.13701E+11
Max Ballast Lamp Distance Remote Wiring:
2'
Net Weight Piece :
1.212 kg
Number Of Lamps:
1 piece/unit
Numerator Packs Per Outer Box:
1
Numerator Quantity Per Pack:
1
Open Circuit Voltage:
120 V
Open Circuit Voltage Test Volts :
114-126 V
Order Code:
9.13701E+11
Order Product Name:
CORE & COIL HID 71A7907001DB
Power Factor Nom :
0.9
Rated Lamp Power:
70 W
Recommended Fuse Value:
3:00 AM
Remote Wiring Configuration Allowed:
Yes
Secondary Short Circuit Current:
1.9-2.9 A
Suitable For Outdoor Use:
Yes
Temperature Marking:
A
Ul Insulation Class:
H(180°C)
Ul Recognized:
Yes
Ul Temperature Code:
1029A
Wire Length By Color:
12"
Wire Striplength:
0.5 mm
Wire Type:
Stranded
Product Core Size:
2 5/8 x 2 3/16
Product Type:
HID Ballast
Department:
Electrical

Philips Lighting 913700500891 – Frequently Asked Questions

1) Will the Philips 913700500891 ballast run a 70W metal halide lamp, or is it HPS only?
HPS only. The 913700500891 is built for a single 70W high pressure sodium lamp carrying ANSI code S62. A 70W metal halide lamp uses a different ANSI designation and a different ballast waveform, so it will not run correctly here. Match the S62 marking on the lamp before you wire it in.
2) Does the 70W HPS Philips core and coil ballast need a separate ignitor and capacitor?
The ignitor is built in, listed as INTEGRAL and rated to 125 C, so no separate starter module is required. The capacitor is a separate piece: it calls for a 28 MFD, 120V capacitor, Philips catalog number 7C280M12RA, rated 105 C, 1.65 in diameter by 2.75 in tall. If you are reusing the fixture's existing cap, confirm it matches that value and voltage or the lamp will not reach full output.
3) Can I mount this HPS ballast remotely from the fixture head?
Remote wiring is allowed, but the run is short: 2 feet maximum from ballast to lamp. That covers a ballast tray in the base of a pole head or just outside the housing, not a ballast box on a wall feeding a distant fixture. The factory leads are 12 inches of stranded wire, so anything past the housing means splicing in a junction box.
4) Will this 120V ballast work on a 277V circuit?
No. This one is single voltage, 120V at 60 Hz only, with an open circuit voltage of 120 V. On a 277V feed it will fail immediately. For 277V or multi-tap service you need a different ballast in the same 70W HPS S62 family, not this model.
5) I have a ballast stamped 71A7907B in the fixture. Is the Philips 913700500891 the same thing?
Yes, 71A7907B is the base model behind the 913700500891, ordered as CORE & COIL HID 71A7907001DB. If the label in your fixture reads 71A7907, you are looking at the same 70W HPS, 120V core and coil assembly. Check that the old unit was also 120V before swapping, since the 71A79 family covers other voltages.
6) Is a 70W HPS core and coil ballast OK in an outdoor parking lot or wall pack fixture?
Yes, it is rated for outdoor use and is a common replacement in site and area lighting. The winding carries UL insulation Class H at 180 C, with the integral ignitor good to 125 C, so it tolerates the heat inside a closed HID housing. Keep the fixture gasketed; the outdoor rating applies to the ballast in a suitable enclosure, not to open exposure.
7) How much current does the Philips 913700500891 draw, and how do I size the branch circuit?
On 120V, 60 Hz it draws 0.75 A nominal at 86 W input power for a 70 W lamp. Starting current is 0.9 A, open circuit 1.3 A, and short circuit 1.9 to 2.9 A. Use the 86 W figure when you total up a pole run of heads, and remember the input wattage is higher than lamp wattage because of ballast losses.
8) What does R-HPF mean on this ballast and does it matter for my utility load?
R-HPF is a regulated high power factor circuit, and here it gives a 0.9 nominal power factor with a ballast factor of 1, meaning full rated lamp lumens. High power factor draws less line current for the same wattage than a normal power factor ballast, which matters when you are loading several heads on one 120V circuit. The regulated design also holds lamp wattage within the trapezoid as line voltage wanders.
9) Is the Philips 913700500891 UL Listed or UL Recognized?
It carries a UL Recognized mark, shown as ULR on the approval marks, with UL temperature code 1029A and temperature marking A. Recognized components are evaluated for use inside a listed fixture rather than as a standalone listed product, which is exactly how a replacement HID ballast gets installed. Hipot ratings are 2000 V for one minute and 2500 V for two seconds.
10) Does this ballast restart the lamp automatically after a power blip?
No automatic restart function is built into the 913700500891. Like any HPS core and coil, the lamp has to cool before it will restrike after an interruption, and this ballast does not include circuitry to force an immediate restart. Plan for the normal HPS cool-down on outdoor heads served by this ballast.
How fast can I get the Philips Lighting 913700500891 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Philips Lighting 913700500891 come with a warranty?
Absolutely. The Philips Lighting 913700500891 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Philips Lighting 913700500891?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Philips Lighting 913700500891 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.