Schneider Electric 9070T Industrial Control Transformer

Professional Power Conversion for Industrial Control Applications

The Schneider Electric 9070T Industrial Control Transformer delivers reliable voltage conversion from 240/480V to 120V for industrial control circuits. This single-phase dry transformer features a 50-500 VA capacity range with screw clamp terminal connections and 105°C insulation temperature rating, providing dependable power transformation for control systems and automation equipment.

Professional Features & Benefits

  • 50-500 VA Capacity Range: Versatile power handling accommodates various control circuit requirements from small pilot devices to larger control panels.
  • 240/480V Primary to 120V Secondary: Standard industrial voltage conversion ensures compatibility with common control voltage requirements.
  • Single Phase Design: Simplified installation and wiring for single-phase control applications with reliable power delivery.
  • 105°C Insulation Temperature: High-temperature insulation rating provides reliable operation in demanding industrial environments.
  • Screw Clamp Terminals: Secure electrical connections ensure reliable power transfer and simplified field wiring.
  • Dry Transformer Construction: Maintenance-free operation without oil or liquid cooling requirements for clean industrial installations.
  • 55°C Temperature Rise: Controlled operating temperature ensures long service life and stable performance under load.

Technical Specifications

  • China Rohs In Scope: No
  • Country Of Origin: Mexico
  • Device Type: Transformer - dry
  • Electrical Connection: screw clamp terminals
  • Environmental Disclosure: ENVPEP1308008EN
  • Eoli Availability Display: No need of specific recycling operations
  • Eu Rohs Directive: Compliant with Exemptions
  • Green Premium Status For Reporting: Green Premium product
  • Html Descr: TRANSFORMER CONTROL 100VA , 208/240/277/380/480 V
  • Insulation Temperature: 105 °C
  • Legacy Weee Scope: In
  • Manufacturer: Schneider Electric
  • Mercury Free: Yes
  • Nema Degree Of Protection: not rated (open device)
  • Packaging Made With Recycled Cardboard: Yes
  • Packaging Without Single Use Plastic: No
  • Phase: 1 phase
  • Product Availability: Stock - Normally stocked in distribution facility
  • Product Compatibility: FSC23
  • Product Contributes To Saved And Avoided Emissions: No
  • Product Or Component Type: Industrial Control Transformer
  • Range Of Product: T
  • Reach Compliance Directive: Reference contains Substances of Very High Concern above the threshold
  • Reach Full Compliance Status: Reference contains Substances of Very High Concern above the threshold
  • Reach Full Compliance Status Id: CONTAINS_SVHC
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • Recycled Metal Content At Cr Level: 0%
  • Relationshiptype: Compatible relationship
  • Return Indicator: Y
  • Returnability: Yes
  • Rohs Eur Conformity Date: 1905
  • Rohs Eur Full Compliance Status: Compliant with Exemptions
  • Rohs Eur Full Compliance Status Id: COMPLIANT_WITH_EXEMPTIONS
  • Rohs Eur In Scope: Yes
  • Rohs Eur Status: Compliant with Exemptions
  • Rohs Exemption Information: Yes
  • Serviceability: No
  • Sustainable Packaging: No
  • Take Back: No
  • Temperature Rise: 55 °C
  • Traceability: No
  • Wd Status: A - SELECTED - PCE ONLY (Migration)
  • With Recycled Cardboard: Yes
  • Without Single Use Plastic: No
  • Department: Electrical

Professional Applications

  • Industrial Control Panels and Automation Systems
  • Manufacturing Equipment Control Circuits
  • Motor Control Centers and Drive Systems
  • Process Control and Instrumentation
  • Machine Tool Control Applications
  • HVAC Control Systems
  • Lighting Control and Power Distribution

Why Choose Schneider Electric Quality?

Schneider Electric 9070T transformers provide proven reliability with 105°C insulation temperature rating and dry transformer construction for maintenance-free operation. The Green Premium product status and RoHS compliance demonstrate commitment to environmental responsibility while delivering dependable industrial control power conversion.

Manufacturer Resources

Product Specs

China Rohs In Scope:
No
Country Of Origin:
Mexico
Device Type:
Transformer - dry
Electrical Connection:
screw clamp terminals
Environmental Disclosure:
ENVPEP1308008EN
Eoli Availability Display:
No need of specific recycling operations
Eu Rohs Directive:
Compliant with Exemptions
Green Premium Status For Reporting:
Green Premium product
Html Descr:
TRANSFORMER CONTROL 100VA , 208/240/277/380/480 V
Insulation Temperature:
105 °C
Legacy Weee Scope:
In
Mercury Free:
Yes
Nema Degree Of Protection:
not rated (open device)
Packaging Made With Recycled Cardboard:
Yes
Packaging Without Single Use Plastic:
No
Phase:
1 phase
Product Availability:
Stock - Normally stocked in distribution facility
Product Compatibility:
FSC23
Product Contributes To Saved And Avoided Emissions:
No
Product Or Component Type:
Industrial Control Transformer
Range Of Product:
T
Reach Full Compliance Status:
Reference contains Substances of Very High Concern above the threshold
Recycled Metal Content At Cr Level:
0%
Relationshiptype:
Compatible relationship
Rohs Eur Conformity Date:
1905
Rohs Exemption Information:
Yes
Serviceability:
No
Sustainable Packaging:
No
Take Back:
No
Temperature Rise:
55 °C
Traceability:
No
Wd Status:
A - SELECTED - PCE ONLY (Migration)
With Recycled Cardboard:
Yes
Without Single Use Plastic:
No
Department:
Electrical
Product Type:
Industrial Control Transformer
Product Group:
Transformers

Schneider 9070T100D19 – Frequently Asked Questions

1) Will the Schneider 9070T control transformer work on a 480V panel and give me 120V control voltage?
That's exactly what the 9070T Type T is built for: 240/480V primary down to 120V secondary, single phase. Wire the primary for whichever of the two line voltages your panel actually runs, and the control circuit sees 120V either way. It's a dry-type transformer, so there's no oil and nothing to service.
2) What VA sizes can I order in the Schneider 9070T control transformer?
Two sizes are orderable: 50 VA (9070T50D19) and 100 VA (9070T100D19). Size it against the sealed VA of everything on the control circuit plus the inrush of the largest contactor coil picking up. If you're running more than a couple of coils, pilot lights and a small PLC power supply, the 50 VA unit will be tight and the 100 VA is the safer pick.
3) Can I mount the Schneider 9070T control transformer on a machine skid or outdoors without an enclosure?
No. The 9070T is an open device with no NEMA protection rating, so it has to live inside a control panel or other enclosure. Anything exposed to washdown, weather, dust or accidental contact needs the enclosure to provide the rating, not the transformer.
4) What do I need besides the 9070T transformer to finish a code-compliant control circuit?
The transformer itself, nothing more, but the circuit around it needs parts the transformer doesn't include: primary fusing or a protective circuit breaker on the line side, secondary protection for the 120V control circuit, and a bonding conductor for the grounded leg of the secondary. There's no enclosure, no cover and no DIN rail adapter in the box, since the 9070T is an open device meant to mount inside a panel.
5) How hot does a 9070T control transformer run inside a packed control panel?
The 9070T is built to a 55 C temperature rise over ambient with 105 C class insulation on the windings. Practically, that means in a 40 C panel the windings sit around 95 C at full load, inside the insulation class. Leave clear space around it and don't stack it under a drive or a heat-producing power supply, because ambient is the part you control.
6) What kind of wire terminations does the Schneider 9070T use, and do I need lugs or crimp terminals?
Screw clamp terminals on both primary and secondary, so stripped conductors or ferruled ends land directly under the clamp. No ring lugs or separate terminal kit to buy. Torque them to Schneider's marked value and re-check after the first heat cycle, which is where control transformer terminations usually loosen.
7) Does the Schneider 9070T meet RoHS and Green Premium requirements for a spec submittal?
The 9070T is a Schneider Green Premium product, EU RoHS compliant with exemptions, and mercury free. Environmental disclosure document ENVPEP1308008EN covers it if a submittal package or a sustainability-minded owner asks for the PEP. One caveat for REACH reporting: the reference does contain Substances of Very High Concern above the threshold, so declare that rather than assume a clean SVHC sheet.
8) Should I use an industrial control transformer like the 9070T or just a small power supply for my panel?
A control transformer is the right call when your loads are 120V AC: contactor and relay coils, solenoid valves, pilot devices, timers. The 9070T handles the inrush of a coil picking up, which a small switching supply will fault on. If the panel is all 24V DC logic, PLC I/O and DC sensors, a DC power supply is the better fit. Panels that run both commonly use a 9070T for the AC control circuit and feed a DC supply from its 120V secondary.
9) Is the 9070T a repairable transformer or a replace-on-failure item?
Replace on failure. The 9070T carries no serviceability, there are no field-replaceable windings or internal parts, and a dry encapsulated control transformer isn't rewound in the field anyway. For an MRO crib standardizing a plant, stock a spare of the VA size you use most rather than planning any repair.
How fast can I get the Schneider 9070T100D19 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Schneider 9070T100D19 come with a warranty?
Absolutely. The Schneider 9070T100D19 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Schneider 9070T100D19?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Schneider 9070T100D19 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.