Appleton PN BRA Series Explosionproof Conduit Plugs & Reducers
Appleton™ PLG Close-Up Plugs and BR Reducers are explosionproof and dust-ignitionproof fittings for use with threaded metal conduit and IMC. The close-up plugs close threaded conduit openings, while the BR reducers create a smaller size opening, and the family spans 1/2" thru 6" in copperfree aluminum, malleable iron, or steel construction. Both are rated for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III hazardous locations, making them a reliable choice for demanding industrial and petrochemical environments.
Key Features
- Trade Size: Available 1/2" thru 6" for closing threaded conduit openings or reducing to a smaller opening size on threaded metal conduit and IMC.
- Durable Construction: BR Reducers are copperfree (4/10 of 1% max.) aluminum with an epoxy powder coat finish, or malleable iron with a triple-coat finish of zinc electroplate, chromate, and epoxy powder coat.
- PLG Plug Materials: Sizes 1/2 thru 1 are copperfree aluminum with a natural finish or steel with zinc electroplate; sizes 1-1/4 thru 6 are copperfree aluminum with a natural finish or malleable iron with zinc electroplate.
- Integral Bushing: Smooth, rounded integral bushing in each hub protects conductor insulation.
- Accurate Threading: Accurately tapped, tapered threads deliver tight, rigid joints and dependable ground continuity.
- Explosionproof & Dust-Ignitionproof: Rated for hazardous location installations per NEC/CEC classifications.
- Finish Option: Urethane paint available on select items (add suffix -UP).
Certifications & Compliance
- Class I, Division 1 and 2, Groups A, B, C, D
- Class II, Division 1 and 2, Groups E, F, G
- Class III
Technical Specifications
- Refer to manufacturer documentation for complete technical specifications.
Typical Applications
- Hazardous Location Electrical Installations
- Threaded Rigid Conduit and IMC Raceway Systems
- Industrial and Petrochemical Facilities
- Closing Unused Threaded Conduit Openings
- Reducing Conduit Opening Size at Enclosures and Fittings
Why Appleton?
Appleton close-up plugs and BR reducers combine copperfree aluminum, malleable iron, or zinc-electroplated steel construction with accurately tapped, tapered threads and a protective integral bushing, delivering the tight, rigid joints and ground continuity electrical professionals expect in hazardous location work. With Class I, Class II, and Class III explosionproof and dust-ignitionproof ratings, these fittings support code-compliant, reliable performance across threaded conduit and IMC installations.
Manufacturer Resources
Product Specs
- Product Type:
- Conduit Plug
- Standards:
- NEC/CEC
- Product Material:
- Aluminum
- Product Size:
- 1/2" - 6"
- Department:
- Electrical
- Product Group:
- Wiring Devices