BEA IXIO-DT1 Dual Technology Motion and Presence Sensor with Ten Microwave Sensitivity Settings
Advanced Radar and Infrared Detection for Automatic Sliding Doors
The BEA IXIO-DT1 combines microwave activation and infrared presence detection technology to deliver comprehensive motion and presence sensing for automatic sliding door applications. This dual technology sensor features ten microwave activation sensitivity settings and three infrared safety immunity settings, with the ability to distinguish between approaching and departing traffic. ANSI compliant with FCC certification and IP54 rating, the IXIO-DT1 ensures reliable performance in commercial environments.
Professional Features & Benefits
- Dual Technology Detection: Combines radar and active infrared technologies for enhanced accuracy and reduced false activations in demanding environments.
- Advanced Sensitivity Control: Ten microwave activation sensitivity settings and three infrared safety immunity settings provide precise tuning for specific applications.
- Traffic Direction Intelligence: Ability to distinguish between approaching and departing traffic optimizes door operation and energy efficiency.
- ANSI Compliance: Engineered to meet ANSI standards for automatic door safety and performance requirements.
- Professional Certifications: FCC certified with IP54 rating for reliable operation in commercial and industrial environments.
- Versatile Applications: Suitable for sliding doors, industrial doors, vehicle gate detection, and off-door automation systems.
- User-Friendly Configuration: Highly flexible adjustment options ensure optimal performance across diverse installation requirements.
Technical Specifications
- Technology: Microwave Doppler Radar + Active Infrared (dual technology)
- Detection Mode: Motion (microwave) + Presence (infrared)
- Transmitter Frequency: 24.150 GHz (microwave)
- Transmitter Radiated Power: < 20 dBm EIRP (microwave)
- Transmitter Power Density: < 5 mW / cm2 (microwave)
- Spot Size: 2 in x 2 in (infrared)
- Max. Number of Spots: 24 per curtain (infrared)
- Max. Number of Curtains: 2 (infrared)
- Output (Electro-mechanical relay): Potential and polarity free | Max. Contact Voltage: 30 VDC | Max. Contact Current: 1 A | Hold Time (microwave): 0.5 s - 9 s
- Output (Solid-state relay): Potential and polarity free | Max. Contact Voltage: 42 VDC | Max. Contact Current: 400 mA | Hold Time (infrared): 0.3 s - 1 s
- Test Input: Sensitivity: Low < 1 V; High > 10 V (max. 30 V) | Response time: typical < 5 ms
- Supply Voltage: 12 - 24 VAC +/-10%; 12 - 30 VDC +/-10% (SELV compatible power supplies only)
- Power Consumption: < 2.5 W
- Temperature Range: -13 deg. F - 131 deg. F; 0 - 95% relative humidity, non-condensing
- Mounting Height: 78 in - 138 in (6.5 ft - 11.5 ft)
- Degree of Protection: IP54
- Applicable Directives: R&TTE 1999/5/EC; EMC 2004/108/EC; MD 2006/42/EC; RoHS 2002/95/EC
- Dimensions: 10.6 in (W) x 2.27 in (H) x 2.25 in (D)
- Cable Length: 120 in (10 ft) (Pedestrian) | 360 in (30 ft) (Industrial)
Installation & Operation
- Verify electrical requirements match available power supply and confirm current capacity before proceeding with installation.
- Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures.
- Mount the sensor in the specified location ensuring adequate clearance for detection zones, wiring access, and future service requirements.
- Route and connect wiring according to manufacturer wiring diagrams. Use appropriate wire gauge and connectors for the application.
- Configure sensitivity settings including microwave activation levels and infrared safety immunity settings per application requirements and traffic patterns.
- Restore power and test all functions including motion detection, presence sensing, traffic direction recognition, and integration with automatic door systems.
- Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.
Professional Applications
- Commercial Building Automatic Door Systems
- Retail Store Entry and Exit Points
- Healthcare Facility Access Control
- Industrial Door Automation
- Vehicle Gate Detection Systems
- Multi-Tenant Building Access Points
- Energy-Efficient Door Control Systems
Why Choose BEA Quality?
BEA IXIO-DT1 sensors deliver professional-grade reliability with dual technology detection and comprehensive certification including FCC approval and IP54 rating. The advanced sensitivity control and traffic direction intelligence ensure optimal performance in demanding commercial applications. Engineered for convenience, safety, and energy efficiency where dependable automatic door operation is essential.
Manufacturer Resources
Product Specs
- Product Type:
- Motion and Presence Sensor
- Series:
- IXIO-DT1
- Subcategory:
- Sensors, Switches, Relays and Timers
- Commercial/Residential:
- Commercial
- Electronic:
- Yes
- Product Group:
- Electronic Access Controls
- Product Subgroup:
- Sensors, Switches, Relays and Timers
- Technology:
- Radar & Active Infrared
- Collection:
- IXIO-DT1
- Product Category:
- Electronic Access Control
- Department:
- Door Hardware