Eaton CH Series Circuit Breaker, 240V, 10 kAIC

The Eaton CH Series Circuit Breaker is a thermal magnetic CHB-type breaker rated 240 V, with a 10 kAIC interrupt rating, engineered for use with Eaton CH Loadcenters. Sized for conductors in the #8-2 AWG range, this circuit breaker delivers reliable overcurrent protection for demanding branch circuits in residential, commercial, and light industrial panels. Backed by UL 489 listing and Eaton's limited lifetime warranty, it's built to deliver dependable, code-compliant performance in CH Loadcenter installations.

Key Features

  • Thermal Magnetic Trip: Thermal magnetic trip design for reliable overcurrent and short-circuit protection.
  • Branch Circuit Protection: Engineered for dependable branch circuit and equipment feeds.
  • Voltage Rating: Rated 240 V for standard commercial and residential distribution systems.
  • Interrupt Rating: 10 kAIC interrupt capacity for safe fault-current handling.
  • Wire Range: Accommodates #8-2 AWG conductors for flexible field wiring.
  • Circuit Breaker Type: CHB-type breaker engineered specifically for compatibility with Eaton CH Loadcenters.
  • Limited Lifetime Warranty: Backed by Eaton's limited lifetime warranty for long-term dependability.

Certifications & Compliance

  • UL 489 Listed

Technical Specifications

  • Used with: CH Loadcenters
  • Voltage rating: 240 V - 240 V
  • Type: Circuit breaker
  • Warranty: Limited lifetime
  • Interrupt rating: 10 kAIC
  • Circuit breaker type: CHB
  • Certifications: UL 489

Typical Applications

  • Residential and Commercial Panelboard Wiring
  • Branch Circuit Protection
  • CH Loadcenter Upgrades and Replacements
  • Equipment and Feeder Circuit Protection
  • New Construction and Electrical Renovation Projects

Why Eaton?

Eaton's CH Series circuit breakers are engineered for dependable, code-compliant performance in CH Loadcenter systems, combining a robust thermal magnetic CHB design with a 10 kAIC interrupt rating and UL 489 listing for safe, reliable circuit protection. Backed by a limited lifetime warranty, this breaker is built for electricians and facility managers who need consistent, long-term performance from every panel component. Choose Eaton for dependable electrical distribution equipment engineered to meet demanding professional standards.

Variant Specifications

Number of PolesAmperageSKU
Single-Pole15 amperesCHB115
Single-Pole20 amperesCHB120
Single-Pole30 amperesCHB130
Single-Pole40 amperesCHB140
Two-Pole100 amperesCHB2100
Two-Pole125 amperesCHB2125
Two-Pole40 amperesCHB240
Two-Pole50 amperesCHB250
Two-Pole70 amperesCHB270
Three-Pole100 amperesCHB3100
Three-Pole50 amperesCHB350
Three-Pole60 amperesCHB360
Single-Pole70 amperesCHB370

Manufacturer Resources

Product Specs

Used With:
CH Loadcenters
Department:
Electrical
Interrupt Rating:
10 kAIC
Product Type:
Circuit Breaker
Certifications:
UL 489
Circuit Breaker Type:
CHB
Warranty:
Limited lifetime
Standards:
UL 489
Product Group:
Circuit Protection
Product Subgroup:
Circuit Breakers

Eaton CHB115 – Frequently Asked Questions

1) Will an Eaton CHB breaker fit a Square D or Siemens panel?
No. The CHB is built for Eaton CH Loadcenters and its mounting is specific to that bus. If your panel is Square D QO/Homeline or Siemens, the CHB will not seat correctly and should not be forced in. Check the panel label for the CH designation before ordering.
2) What wire sizes can I land on an Eaton CHB circuit breaker?
The CHB lug accepts conductors in the #8 to #2 AWG range. That covers typical 40 to 125 amp feeder and equipment circuits. If you are landing #14 or #12 branch wiring, you are below that range and a smaller CH branch breaker is the right part.
3) Which Eaton CHB breaker do I order for a 240V two-pole circuit?
Two-pole CHB breakers come in 40 A (CHB240), 50 A (CHB250), 70 A (CHB270), 100 A (CHB2100), and 125 A (CHB2125). Pick the amperage to match the conductor and the equipment nameplate, then confirm the panel has two adjacent spaces free.
4) Is there a three-pole Eaton CHB breaker for a three-phase panel?
Three-pole CHB breakers are offered at 50 A (CHB350), 60 A (CHB360), and 100 A (CHB3100). They take three adjacent poles in a CH Loadcenter and carry the same 240 V, 10 kAIC rating as the single- and two-pole versions.
5) Does the CHB use thermal magnetic tripping or is it an electronic breaker?
Thermal magnetic. A bimetal element handles sustained overloads and a magnetic element handles short circuits. There is no electronic trip unit to set up, and no ground fault or arc fault sensing in this breaker, so if the circuit needs GFCI or AFCI protection you need a dedicated CH GFCI or AFCI breaker instead.
6) What single-pole amperages are available in the Eaton CHB line?
Single-pole CHB breakers are offered at 15 A (CHB115), 20 A (CHB120), 30 A (CHB130), 40 A (CHB140), and 70 A (CHB370). All are 240 V rated, so a single pole can be used on a 120 V branch circuit in a CH Loadcenter.
7) I manage several buildings with Eaton CH panels. Can I standardize on CHB breakers across all of them?
If the panels are Eaton CH Loadcenters, yes, the CHB is the matching breaker type and one part family covers 15 A single-pole through 125 A two-pole and 100 A three-pole. Stocking a few common ratings, typically 20 A single-pole and 50 A two-pole, covers most service calls. Panels of other makes in the same portfolio will need their own breaker type.
8) Can I use a CHB breaker as a main in a CH loadcenter?
The CHB is a branch circuit and feeder breaker, described for branch circuit protection and equipment feeds in CH Loadcenters. Larger ratings like the 100 A and 125 A two-pole are commonly used as feeder or subpanel supply breakers backfed or fed from the bus per the panel's instructions. Whether a given loadcenter permits a main breaker in that position is determined by the panel labeling, not the breaker.
How fast can I get the Eaton CHB115 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Eaton CHB115 come with a warranty?
Absolutely. The Eaton CHB115 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Eaton CHB115?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Eaton CHB115 from ZenSupply?