Crouse-Hinds Zinc Die Cast Ins...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$17.19

Crouse-Hinds Zinc Die Cast Insulated Throat Grounding Bushing

(No reviews yet) Write a Review

Model: GLL8DC

In Stock (leaves warehouse same day if ordered before 3pm ET)

$17.19
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Crouse-Hinds Zinc Die Cast Insulated Throat Grounding Bushing

Professional electrical grounding solution for secure conduit connections

The Crouse-Hinds Zinc Die Cast Insulated Throat Grounding Bushing delivers reliable electrical grounding performance for professional conduit installations. Featuring durable zinc die cast construction with insulated throat design, this grounding bushing ensures secure electrical connections while providing protection against moisture and environmental factors in commercial and industrial applications.

Professional Features & Benefits

  • Zinc Die Cast Construction: Provides exceptional durability and corrosion resistance for long-lasting performance in demanding environments.
  • Insulated Throat Design: Protects conductors from damage while maintaining proper electrical isolation and grounding integrity.
  • Professional Grade Materials: Engineered for reliable performance in commercial, industrial, and institutional electrical systems.
  • Secure Grounding Connection: Ensures proper electrical grounding compliance with safety standards and code requirements.
  • Versatile Installation: Compatible with standard conduit systems for flexible application across various project types.
  • Crouse-Hinds Quality: Backed by decades of electrical industry expertise and proven reliability in professional installations.

Technical Specifications

  • Limited technical data available.

Professional Applications

  • Commercial Building Electrical Systems
  • Industrial Facility Conduit Installations
  • Institutional and Educational Facilities
  • Healthcare and Medical Facilities
  • Retail and Office Buildings
  • Manufacturing and Processing Plants
  • Municipal and Government Buildings

Why Choose Crouse-Hinds Quality?

Crouse-Hinds delivers proven reliability and professional-grade performance in electrical grounding solutions. With zinc die cast construction and insulated throat protection, this grounding bushing provides the durability and safety compliance required for demanding commercial and industrial electrical installations.

Manufacturer Resources

Product Specs

Department:
Electrical
Product Type:
Conduit Fittings
Product Subgroup:
Electrical
Product Material:
Zinc Die Cast
Thread:
Threaded

Crouse-Hinds GLL8DC – Frequently Asked Questions

1) What trade sizes does the Crouse-Hinds GLL grounding bushing come in?
The Crouse-Hinds zinc die cast insulated throat grounding bushing runs the full conduit range: 1/2 inch (GLL1DC), 3/4 inch (GLL2DC), 1 inch (GLL3DC), 1-1/4 inch (GLL4DC), 1-1/2 inch (GLL5DC), 2 inch (GLL6DC), 2-1/2 inch (GLL7DC), 3 inch (GLL8DC), 3-1/2 inch (GLL9DC) and 4 inch (GLL10DC). Order by the trade size of the conduit or the threaded hub you are landing on, not by the knockout diameter.
2) Do I still need a plastic bushing if I use a grounding bushing on the conduit?
No. The GLL series has the insulated throat built in, so one fitting does both jobs: it protects the conductor insulation where the wire leaves the raceway and it gives you a lug to land the bonding jumper. Adding a separate insulating bushing on top of it is redundant.
3) Which grounding bushing do I use on a 4 inch service conduit entering a switchgear enclosure?
For 4 inch conduit the part is GLL10DC, the largest size in the Crouse-Hinds zinc die cast insulated throat grounding bushing range. Service entrance raceways are exactly where a grounding bushing earns its place, since the concentric and eccentric knockouts common on gear enclosures need a bonding path back to the ground bus rather than relying on the locknut alone.
4) Will a grounding bushing thread onto EMT, or do I need rigid conduit?
The GLL bushing is a threaded fitting, so it lands on rigid or IMC conduit ends and on the threaded ends of set screw or compression EMT connectors. It does not thread directly onto bare EMT, since EMT has no threads on the tube itself. On an EMT run you put the connector through the knockout first, then the grounding bushing on the connector threads inside the enclosure.
5) How do I match a grounding bushing to conduit size when the box knockout is a different size?
Size the bushing to the conduit or connector thread, never to the knockout. If a 1 inch conduit lands in an oversized knockout, you still order GLL3DC for the 1 inch thread and use reducing washers to close the opening. Getting this backwards is the most common reason a grounding bushing arrives and will not thread on.
6) Is a zinc die cast grounding bushing okay outdoors or in a damp mechanical room?
Zinc die cast is the body material here, and it holds up in wet and corrosive spots where a plain steel fitting rusts at the threads. Crouse-Hinds calls out moisture and environmental protection for commercial and industrial use, which covers rooftop runs, parking structures and mechanical rooms. For heavy chemical exposure most electricians step up to a malleable iron or PVC coated fitting instead.
7) What is the difference between a grounding bushing and a bonding locknut?
A bonding locknut bites into the enclosure metal to bond a knockout and sits on the outside of the box. A grounding bushing like the GLL goes on the conduit end inside the enclosure, protects the wire at the throat, and gives you a screw lug so a bonding jumper can run to the ground bus. On service raceways and where concentric knockouts break the bonding path, the jumper and lug is the approach most inspectors expect to see.
8) Can I standardize on one grounding bushing line across a whole facility?
Yes, and that is the practical argument for the GLL series: one family covers 1/2 inch through 4 inch, all zinc die cast with the same insulated throat, so a maintenance stockroom carries one line instead of mixing brands by size. Stock the sizes your branch circuits and feeders actually use, typically 1/2 inch (GLL1DC) and 3/4 inch (GLL2DC) in volume with the larger feeder sizes in ones and twos.
How fast can I get the Crouse-Hinds GLL8DC delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Crouse-Hinds GLL8DC come with a warranty?
Absolutely. The Crouse-Hinds GLL8DC is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Crouse-Hinds GLL8DC?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Crouse-Hinds GLL8DC from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.