Milbank 200A Ringless Lever By...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$756.11

Milbank 200A Ringless Lever Bypass Meter Socket 5-Terminal 600V Single Phase Surface Mount

(No reviews yet) Write a Review

Model: U4551-RXL

In Stock (leaves warehouse same day if ordered before 3pm ET)

$756.11
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Milbank 200A Ringless Lever Bypass Meter Socket 5-Terminal 600V Single Phase Surface Mount

Professional electrical metering solution with lever bypass functionality

The Milbank 200A Ringless Lever Bypass Meter Socket delivers reliable single-phase electrical metering with convenient bypass capability. This surface-mount unit features a durable G90 galvanized steel construction with powder coat finish and Type 3R enclosure rating for dependable outdoor performance. The 5-terminal configuration accommodates overhead or underground cable entry with flexible wire range capacity from 6 AWG to 350 kcmil on both line and load sides.

Professional Features & Benefits

  • 200A Continuous Rating: Handles substantial electrical loads for residential and light commercial applications with reliable amperage capacity.
  • Lever Bypass Provision: Enables safe meter removal and replacement without service interruption for maintenance flexibility.
  • 600V AC Rating: Supports higher voltage applications with robust electrical performance and safety margins.
  • Type 3R Enclosure: Weather-resistant construction protects internal components from rain, sleet, and ice formation.
  • G90 Galvanized Steel: Corrosion-resistant material with powder coat finish ensures long-term durability in outdoor environments.
  • Flexible Cable Entry: Accommodates both overhead and underground installations for versatile application compatibility.
  • UL Listed: Meets rigorous safety standards for professional electrical installations and code compliance.

Technical Specifications

  • Amperage Rating: 200 Continuous Ampere
  • Application: Meter Socket
  • Brand Name: Milbank
  • Bypass Provision: Lever Bypass
  • Cable Entry: Overhead or Underground
  • Departent: Electrical
  • Equipment Ground: Ground Lug
  • Frequency Rating: 60 Hertz
  • Insulation: Glass Polyester
  • Line Side Wire Range: 6 AWG - 350 kcmil
  • Load Side Wire Range: 6 AWG - 350 kcmil
  • Main Breaker Size: No Main Breaker
  • Number Of Jaws: 5 Terminal
  • Number Of Main Breakers: 0
  • Number Of Meter Positions: 1 Position
  • Number Of Receptacles: 0
  • Phase: 1 Phase
  • Product Family Code: HD5T
  • Product Height: 19 IN
  • Product Length: 4.906 IN
  • Product Material: G90 Galvanized Steel with Powder Coat Finish
  • Product Mounting: Surface Mount
  • Product Size: 4.906L x 13W x19H
  • Product Type: Ringless Meter Socket
  • Standard: UL Listed;Type 3R
  • Terminal: Lay in
  • Unspsc Number: 39121102
  • Voltage Rating: 600 Volts Alternating Current
  • Width: 13 IN

Professional Applications

  • Residential electrical service metering and distribution
  • Small commercial facility power monitoring
  • Multi-unit residential properties
  • Professional office buildings
  • Retail establishments requiring reliable metering
  • Light industrial applications
  • Utility company meter installations

Why Choose Milbank Quality?

Milbank delivers proven reliability with UL Listed safety certification and Type 3R weather protection. The robust G90 galvanized steel construction with powder coat finish ensures long-term performance in demanding outdoor environments, while the comprehensive wire range compatibility and professional-grade insulation provide dependable electrical service for years of operation.

Manufacturer Resources

Product Specs

Amperage Rating:
200 Continuous Ampere
Application:
Meter Socket
Brand Name:
Milbank
Bypass Provision:
Lever Bypass
Cable Entry:
Overhead or Underground
Equipment Ground:
Ground Lug
Frequency Rating:
60 Hertz
Insulation:
Glass Polyester
Line Side Wire Range:
6 AWG - 350 kcmil
Load Side Wire Range:
6 AWG - 350 kcmil
Main Breaker Size:
No Main Breaker
Number Of Jaws:
5 Terminal
Number Of Main Breakers:
0
Number Of Meter Positions:
1 Position
Number Of Receptacles:
0
Phase:
1 Phase
Product Family Code:
HD5T
Product Height:
19 IN
Product Length:
4.906 IN
Product Size:
4.906L x 13W x19H
Product Type:
Ringless Meter Socket
Standards:
UL Listed;Type 3R
Terminal:
Lay in
Unspsc Number:
39121102
Voltage Rating:
600 Volts Alternating Current
Product Material:
G90 Galvanized Steel with Powder Coat Finish
Product Mounting:
Surface Mount
Amps:
200
Product Width:
13 IN
Department:
Electrical
Product Subgroup:
Metering & Meter Sockets
Insulation Type:
Glass Polyester
Installation Category:
Surface Mount
Terminal Type:
Lay In
Number of Phases:
1
Frequency:
60 hertz
Product Details:
Ringless Meter Socket
Number of Terminations:
5
Product Group:
Power Distribution

Milbank U4551-RXL – Frequently Asked Questions

1) Will the Milbank U4551 meter socket take 4/0 aluminum service entrance cable?
Yes. The U4551 socket's lay-in terminals accept 6 AWG through 350 kcmil on both the line and load sides, so 4/0 falls well inside the range. Same window on both sides, which means you can land the utility service conductors and the feeder to the panel without adapters or reducers.
2) Does this 200A Milbank socket include a main breaker or disconnect?
No. The U4551 is a meter socket only, with no main breaker and no provision for one, and it carries a single meter position. You still need a separate service disconnect or main breaker panel downstream. If your utility or the AHJ requires a disconnect at the meter, order a meter main combination instead of this socket.
3) What is the difference between the U4551-RRL, U4551-RXL and U4551-RXL-5T9?
All three are 200A ringless lever bypass sockets with external hex. The RRL is the standard 5-terminal unit. The RXL comes with a small closing plate. The RXL-5T9 locates the 5th terminal at the 9 o'clock position. Utilities are specific about 5th terminal position and closing plate style, so match the variant to what your serving utility's meter spec calls out.
4) Do I need a 5-terminal meter socket or will a 4-terminal work?
The U4551 is a 5-jaw socket. The fifth jaw is what utilities require for 120/208V network or certain three-wire metering arrangements, and many utilities simply standardize on 5-terminal for new single-phase services. A 4-terminal meter will physically seat in a 5-jaw socket, but a 5-jaw meter will not fit a 4-terminal socket, so the utility's meter determines the choice. Check the service order before you set the can.
5) Can this meter socket be mounted outdoors on an exterior wall?
Yes. The U4551 is a surface mount can with a Type 3R enclosure rating, built from G90 galvanized steel with a powder coat finish, so it handles rain, sleet and ice on an exterior wall. It is not flush or semi-flush, so it mounts on the face of the wall or a backboard, not recessed into it.
6) What does the lever bypass actually do on a job, and do I need it?
The lever bypass lets a utility tech or electrician shunt current around the meter so the meter can be pulled and swapped without dropping power to the building. On occupied multi-family, retail or office service, that is the difference between a meter change and an outage notice. Many utilities require bypass on 200A sockets; if yours does not, a non-bypass socket is the simpler order.
7) Is the Milbank U4551 ringless, and can I use a ring-type meter on it?
It is a ringless socket, meaning the cover slides over the socket and is secured by the external hex fastener rather than a sealing ring clamping the meter. Ringless and ring-type covers are not interchangeable, so the utility's meter spec has to call for ringless. The socket itself is 600V AC, 60 Hz, single phase.
8) Can I use this socket for an underground service lateral, or is it overhead only?
Either. Cable entry is rated for overhead or underground, so the same can works for a service drop from a mast or a lateral coming up from below. Note that no hub is part of the socket itself, so the conduit hub or weatherhead fitting for your entry method is a separate item.
9) Is the Milbank U4551 UL Listed for a permitted residential service upgrade?
Yes, the U4551 is UL Listed and rated Type 3R, which is what an inspector looks for on an outdoor service meter socket. It is a 200A continuous rated single phase device at 600V AC.
10) Is there a ground lug in the Milbank U4551, or do I add a ground bar kit?
A ground lug for the equipment ground is part of the socket, so you can bond the enclosure and land the grounding electrode conductor without a separate kit. The internal insulation is glass polyester.
How fast can I get the Milbank U4551-RXL delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Milbank U4551-RXL come with a warranty?
Absolutely. The Milbank U4551-RXL is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Milbank U4551-RXL?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Milbank U4551-RXL from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.