The strainer is a "Y" type with a branch angled off the flow path. It features a tapped cap with blow-off plug for screen maintenance. The strainers are equipped with female threaded end connections for easy installation. Please refer to NIBCO technical data sheets, chemical resistance guides and catalogs for engineering and installation information. Choose NIBCO® valves for the most specified, versatile and economical valve option in commercial, mechanical and industrial applications. NIBCO® strainers are backed by the NIBCO 5-year 125% limited warranty.
- 125 psi/8.6 bar saturated steam to 353-DegreeF/178-DegreeC
- 200 psi/13.8 bar non-shock cold working pressure
- 20-mesh stainless steel wire screen
- Tapped cap with plug
- Class 125 threaded end connections
- Dezincification resistant
- Use in U.S. drinking water applications is prohibited after January 3, 2014
- Conforms to ANSI B1.20.1
Manufacturer Resources
Product Specs
- All Basic Material:
- Bronze
- Classification:
- Bronze Strainers
- End Connection:
- Threaded
- Product Group:
- Strainer
- Type of Valve:
- Strainer
- Valve End Connection Type:
- T -- Female NPT Thread (FIPT)
- Product Type:
- Bronze Strainers
- Department:
- Plumbing
Nibco NL2QA0D – Frequently Asked Questions
1) Will the Nibco T-221-A bronze strainer thread onto my existing steel pipe, or do I need adapters?
Both ends are female NPT (FIPT) threads conforming to ANSI B1.20.1, so it threads directly onto any standard male NPT pipe nipple or fitting of matching size. No flanges, no soldering, no adapters. It's built in 3/4 inch, 1-1/2 inch, and 2 inch pipe sizes.
2) Can I use a Nibco T-221-A strainer on a potable water line?
No. Use in U.S. drinking water applications is prohibited after January 3, 2014. Keep the T-221-A on non-potable service: steam, condensate, hydronic heating and chilled water, compressed air, and process lines. If the line feeds fixtures people drink from, you need a lead-free strainer instead.
3) What pressure and temperature can the Nibco T-221-A handle on a steam line?
Rated 125 psi (8.6 bar) saturated steam up to 353 degrees F (178 degrees C), and 200 psi (13.8 bar) non-shock cold working pressure. That's a Class 125 body, so it suits low pressure steam and standard hydronic work. Higher pressure steam mains need a Class 250 or cast steel strainer.
4) How do I clean out a Y strainer without draining the system?
The T-221-A has a tapped cap with a blow-off plug. Pull the plug and blow down the screen while the line stays under pressure, which is how most MRO crews service these on a schedule. For a full clean you back the cap out and lift the 20-mesh stainless screen out of the branch pocket. Leave clearance below the branch for cap removal when you set the strainer in the line.
5) Which way does a Y strainer get installed, and does orientation matter?
Orientation matters. The T-221-A is a Y pattern with the branch angled off the flow path, and that branch holds the screen and the debris. On horizontal pipe the branch points down or to the side so solids collect in the pocket. Pointed up, debris falls back into the line every time flow drops. Install it with flow following the body arrow so the screen is loaded from inside out.
6) How fine is the screen in the Nibco T-221-A, and will it protect a pump seal or control valve?
The screen is 20-mesh stainless steel wire. That catches scale, weld slag, pipe chips, and grit ahead of pump seals, control valves, and coils, which is the usual reason a Y strainer goes in. It is a coarse-to-medium mesh, not a filter, so it won't remove fine sediment or rust bloom.
7) Is bronze the right strainer body for a building with aggressive or high-chloride water?
The T-221-A body is bronze and dezincification resistant, so it holds up in water chemistries that strip zinc out of ordinary brass and leave the fitting porous. That's the common failure mode in older hydronic and cooling loops with high chloride or low pH make-up water. For chemical service, check the fluid against the NIBCO chemical resistance data before committing.
8) Can I standardize on one strainer part number across a property's mechanical rooms?
Within the 3/4 inch, 1-1/2 inch, and 2 inch threaded range, yes. The T-221-A carries the same bronze body, same 20-mesh stainless screen, and same tapped cap with blow-off plug at every size, so one service procedure and one spare screen habit covers all three. Order by size: 3/4 inch is MPN NL2QA08, 1-1/2 inch is NL2QA0C, and 2 inch is NL2QA0D. The one hard limit on standardizing is potable water, where this strainer cannot be used.
9) What sizes does the Nibco T-221-A strainer come in?
Three threaded sizes: 3/4 inch, 1-1/2 inch, and 2 inch. Size the strainer to the line, not the pump port. Going down a size to match a smaller pump connection chokes flow and drives the screen to blind faster.
How fast can I get the Nibco NL2QA0D delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the
continental
U.S.
Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit,
reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Nibco NL2QA0D come with a warranty?
Absolutely. The Nibco NL2QA0D is backed by a manufacturer’s warranty.
For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Nibco NL2QA0D?
You can call, text, or email our expert support team for fast answers. We’re here to help with
product
selection,
installation tips, and troubleshooting. Contact Us
Why buy the Nibco NL2QA0D from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support,
and
rewards on
every order.
Our team is always ready to help you choose the right product for your project.