Philips Lighting 913700533009 Core & Coil HID Ballast, 100W Metal Halide, 120/208/240/277V

Philips Lighting 913700533009 is a Magnetic HID, HX-HPF Core & Coil ballast engineered to operate 100W Metal Halide (100 MH) lamps rated ANSI M90-M140. Built for multi-voltage input at 120/208/240/277V, this ballast pairs a dedicated LI533-H4 ignitor and a 7C120M30RA capacitor (280V, 12 MFD) for reliable starting and running performance. It is UL Recognized (ULR) and rated for outdoor use, making it a dependable component for commercial and industrial HID lighting fixtures that require code-compliant, multi-voltage operation.

Key Features

  • Lamp Compatibility: ANSI M90-M140 rating for 100W Metal Halide (100 MH) lamps.
  • Multi-Voltage Input: Operates on 120/208/240/277V for flexible field installation across common branch circuits.
  • HX-HPF Circuit Type: High Reactance, High Power Factor Core & Coil design with a nominal power factor of 0.9 and constant wattage deviation of 12%.
  • Rated Lamp Power: 100W nominal input power of 129W for accurate lamp matching.
  • Ignitor: LI533-H4 ignitor rated to 105°C for reliable Metal Halide lamp starting.
  • Capacitor: 7C120M30RA capacitor rated 280V, 12 MFD, 105°C for stable ballast operation.
  • Remote Wiring Capability: Supports remote wiring configuration up to a maximum ballast-to-lamp distance of 20', with 12" stranded wire leads.
  • Insulation Class: UL Insulation Class H (180°C), UL Temperature Code 1029B, and outdoor-rated construction.

Certifications & Compliance

  • UL Recognized (ULR)
  • Outdoor Rated

Technical Specifications

  • Approval Marks: ULR
  • Automatic Restart: No
  • Ballast Factor Nom: 1
  • Base Model: 71A5390
  • Constant Wattage Deviation: 12%
  • Max Ballast Lamp Distance Remote Wiring: 20'
  • Numerator Packs Per Outer Box: 1
  • Numerator Quantity Per Pack: 1
  • Order Product Name: CORE & COIL HID 71A5390001D
  • Power Factor Nom: 0.9
  • Remote Wiring Configuration Allowed: Yes
  • Suitable For Outdoor Use: Yes
  • Ul Recognized: Yes
  • Wire Length By Color: 12"

Typical Applications

  • Outdoor HID Lighting
  • Metal Halide Lamp Systems
  • Commercial and Industrial HID Fixtures
  • Remote-Mount Ballast Installations

Why Philips Lighting?

Philips Lighting delivers UL Recognized HID ballast performance for demanding lighting applications. The HX-HPF Core & Coil design, paired LI533-H4 ignitor, and 7C120M30RA capacitor provide dependable starting and running performance, while multi-voltage 120/208/240/277V input and outdoor-rated, Class H insulated construction support reliable, code-compliant operation for 100W Metal Halide systems in commercial and industrial installations.

Manufacturer Resources

Product Specs

Ansi Code:
M90-M140
Approval Marks:
ULR
Automatic Restart:
No
Ballast Factor Nom :
1
Ballast Type:
Magnetic HID
Base Model:
71A5390
Capacitor Catalog Number:
7C120M30RA
Capacitor Diameter Oval Dimensions:
1.65 in
Capacitor Height:
2.75 in
Capacitor Requirements:
280V
Capacitor Temperature Rating:
105°C
Capacitor Value:
12 MFD
Circuit Type:
HX-HPF
Constant Wattage Deviation:
12%
Ean Upc Product:
7.81087E+11
Hipot Test 1 Minute :
2000 V
Hipot Test 2 Seconds :
2500 V
Ignitor Catalog Number:
LI533-H4
Ignitor Temperature Rating:
105°C
Input Current Nom :
1.15/0.66/0.58/0.5 A A
Input Current Open Circuit :
2.5/1.5/1.3/1.12 A
Input Current Short Circuit :
0.63-0.95/0.43-0.65/0.37-0.55/0.29-0.44 A
Input Current Starting :
1.24/0.54/0.45/0.4 A
Input Frequency:
60 Hz
Input Power Nom :
129 W
Input Voltage:
120/208/240/277 V
Lamp Type:
100 MH
Material Nr 12nc :
9.13701E+11
Max Ballast Lamp Distance Remote Wiring:
20'
Net Weight Piece :
2.541 kg
Number Of Lamps:
1 piece/unit
Numerator Packs Per Outer Box:
1
Numerator Quantity Per Pack:
1
Open Circuit Voltage:
260 V
Open Circuit Voltage Test Volts :
240-300 V
Order Code:
9.13701E+11
Order Product Name:
CORE & COIL HID 71A5390001D
Power Factor Nom :
0.9
Rated Lamp Power:
100 W
Recommended Fuse Value:
10/5/5/4 A
Remote Wiring Configuration Allowed:
Yes
Secondary Short Circuit Current:
1.35-1.7 A
Suitable For Outdoor Use:
Yes
Temperature Marking:
B/B/A/A
Ul Insulation Class:
H(180°C)
Ul Recognized:
Yes
Ul Temperature Code:
1029B
Wire Length By Color:
12"
Wire Striplength:
0.5 mm
Wire Type:
Stranded
Product Core Size:
3 X 4 (2 LW)
Product Type:
HID Ballast
Department:
Electrical

Philips Lighting 913700533009 – Frequently Asked Questions

1) Does the Philips 913700533009 ballast come with the capacitor and ignitor, or do I order those separately?
The kit is built around a matched capacitor and ignitor: capacitor 7C120M30RA, 12 MFD at 280V, rated 105 degrees C, measuring 1.65 in oval diameter by 2.75 in high, and ignitor LI533-H4 also rated 105 degrees C. Those are the exact part numbers to call out if one of the three components ever needs replacing on its own.
2) Can I mount this HID ballast away from the fixture and run leads to the lamp?
Remote wiring is allowed, with a maximum ballast to lamp distance of 20 feet. Beyond that run length the starting pulse from the ignitor is no longer supported. Leads are 12 inch stranded wire with a 0.5 mm strip length.
3) What fuse size should I use on a 100W metal halide core and coil ballast?
Recommended fuse value tracks the voltage tap: 10 A on 120V, 5 A on 208V, 5 A on 240V and 4 A on 277V. Starting current runs 1.24 A at 120V down to 0.4 A at 277V, and open circuit current can reach 2.5 A at 120V, so size the fuse to the published value rather than to running current alone.
4) Is this 100W metal halide ballast rated for an outdoor pole or wall pack fixture?
Outdoor use is approved, and the ballast carries UL Insulation Class H at 180 degrees C with UL temperature code 1029B. It is UL Recognized as a component, meaning it is intended for installation inside a listed fixture or enclosure rather than as a standalone assembly.
5) What is the difference between an HX-HPF ballast and a CWA ballast for 100W metal halide?
HX-HPF is a high reactance, high power factor magnetic core and coil circuit. It holds a 0.9 nominal power factor, which keeps line current low enough for multiple fixtures on a branch circuit, but lamp wattage moves about 12 percent with line voltage swing. A constant wattage autotransformer circuit holds wattage tighter against poor line regulation. If your feed is stable, HX-HPF is the normal choice for 100W metal halide; if voltage sags on the circuit, specify a CWA type instead.
6) Will the lamp restrike on its own after a momentary power blip?
No. Automatic restart is not a feature of this magnetic HID ballast, so after an interruption the metal halide lamp has to cool before it will re-strike. Where that downtime is a problem, the usual fix is a quartz restrike socket in the fixture or emergency lighting on a separate circuit.
7) How do I confirm the Philips 913700533009 fits the ballast tray in my existing fixture?
Core size is 3 x 4 with a 2 lamination width stack, and the unit weighs 2.541 kg. Base model is 71A5390, ordered as CORE & COIL HID 71A5390001D. Match the core size and mounting footprint to the tray before pulling the old one, since core and coil ballasts bolt in on the core stack rather than a standard case.
8) What open circuit voltage should I read at the ballast output when testing a 100W MH ballast?
Open circuit voltage is 260V nominal, with an acceptable test window of 240 to 300V. Secondary short circuit current should fall between 1.35 and 1.7 A. Readings outside those ranges point at a failed winding rather than a bad lamp or ignitor.
9) How many ballasts come in a box on the Philips 913700533009?
It ships one per pack, one pack per outer box, so each order unit is a single ballast with its ignitor and capacitor. Plan quantities per fixture when standardizing a site of 100W metal halide luminaires.
How fast can I get the Philips Lighting 913700533009 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Philips Lighting 913700533009 come with a warranty?
Absolutely. The Philips Lighting 913700533009 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Philips Lighting 913700533009?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Philips Lighting 913700533009 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.