Schlage L9095EL - Electrified ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$2,169.00
$1,518.30

Schlage L9095EL - Electrified Mortise Lock - Grade 1, Fail Safe, Both Levers EL, Double Cylinder Override, 12/24VDC

(No reviews yet) Write a Review

Model: L9095ELP 17A 626
From the L9000 Series Collection
$2,169.00
$1,518.30
Selected Finish is
Selected Lever Style is
Selected ROSE/ESCUTCHEON DESIGN is
Selected Cylinder Type is
  • Schlage ADDER-SCHLAGE-COMMERCIAL-[KEYING]=KD - Keyed Different ADDER-SCHLAGE-COMMERCIAL-[KEYING]=KD - Keyed Different
  • Schlage ADDER-SCHLAGE-COMMERCIAL-[KEYING]=KA - Keyed Alike ADDER-SCHLAGE-COMMERCIAL-[KEYING]=KA - Keyed Alike
  • Schlage ADDER-SCHLAGE-COMMERCIAL-[KEYING]=None (Select for Less Cylinder Options) ADDER-SCHLAGE-COMMERCIAL-[KEYING]=None (Select for Less Cylinder Options)

In Stock (leaves warehouse same day if ordered before 3pm ET)

$2,169.00
$1,518.30
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

L9095EL - ELECTRICALLY LOCKING/UNLOCKING BOTH LEVERS, DOUBLE CYLINDER OVERRIDE

  • Both knobs/levers continuously locked (EL) or unlocked (EU) by 12V or 24V DC;
  • Latchbolt retracted by either key;
  • Auxiliary latch deadlocks latchbolt when door is closed;
  • EL: Switch or power failure unlocks both knobs/levers and allows knob/lever to retract latchbolt;
  • EU: Switch or power failure locks both knobs/levers.


Schlage L SERIES OVERVIEW

The Schlage L Series has long been the benchmark for mortise locks. The L Series is more than strength and security – it offers tremendous flexibility to allow it to meet the needs of most every application. Over 55 functions, 35 lever and knob designs, eight different roses and escutcheons, and a multitude of prep options are just the beginning.

180 degree visibility indicators, advanced motor-driven electrified functions, a universal lock case that supports 10 different functions, and the ability to suite across tubular, exit device, and multipoint locks allow the Schlage L Series to integrate seamlessly into any environment.


FEATURES & BENEFITS

Security

  • Exceeds ANSI/BHMA Grade 1 Security and Operational standards
  • Deadbolt functions include anti-saw pin in bolt to prevent cut-through
  • Security blocking hub prevents lock picking by removing levers

Function availability and compatibility

  • 55+ standard functions (custom functions are also available)
  • Universal lock case allows 10 functions to be created from a single lock body
  • Electrified locks auto detect 12V/24V DC, have customer-selectable EL/EU, and offer advanced features like: RX, DPS, latchbolt monitor and deadbolt monitor for application flexibility while offering leading energy efficiency

Aesthetics

  • 14 finishes
  • 33 lever, two knob, five rose and three escutcheon designs
  • Locking lever bushing eliminates exposed screws on inside levers
  • All levers suite with Von Duprin exit devices, along with related L Series products LE, LM9200, LM9300 and LT

Options

  • Exclusive 180° visibility indicator
  • Vandlgard® free-wheeling outside trim option is available on most functions, including electrified
  • Expansive options portfolio, including different door thickness, finish/trim combinations, tactile warning, anti-microbial coatings, etc.
  • New Gold Standard ligature resistant trim for behavioral health applications


AVAILABLE L SERIES FUNCTIONS

View the Schlage L Series catalog for descriptions of all available functions.


CERTIFICATIONS & TESTING

View the Schlage L Series catalog to see all specifications and certifications.

Certifications

  • Meets BAA (Buy American Act)
  • L9000: tested and certified under ANSI/BHMA A156.13, Grade 1 Security and Operational
  • UL listed for 3-hour fire door (except L9076 and L9077)
  • With interchangeable core cylinders: Grade 2 security
  • With concealed shell cylinder: A156.13 Grade 1 operational and security
  • ANSI/ASTM F476-76 Grade 40, UL listed
  • L400: tested and certified under ANSI/BHMA A156.36 Grade 1
  • California Referenced Standards Code: all levers with a return to door of 1/2" (64 mm) or less comply
  • UL/cUL listed for A label single doors, 4' x 10' and pairs 8' x 10'; letter F and UL symbol on latch front indicate listing
  • Electrified functions are UL19X listed for single-point locking applications
  • UL437 listed locking cylinder optional: specify Primus 20-500 Series cylinder
  • Miami-Dade NOA's and Florida Building Commission Listings
  • Meet ADA requirements

DOWNLOADS & RESOURCES



Technical resources


Manufacturer Resources

Product Specs

Subcategory:
Mortise Locks
Product Group:
Mechanical Locks
Series:
L Series
Function Description:
Inside and outside knob/lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. Latchbolt retracted by key inside or outside. Auxiliary latch deadlocks latchbolt when door is closed.
Grade:
Grade 1
Duty Level:
Heavy Duty
Keyed Function:
Double Cylinder
Standard Cylinder:
Double Cylinder, Conventional Cylinder, 6-pin, S123 Keyway
Handle Type:
Lever
Standard Latch:
3/4" Stainless Steel Latch with Anti-Friction Tongue
Standard Strike:
10-072 1-1/4" x 4-7/8" Square Corner Strike, Box (1-3/16" Lip Length)
Mortise Case Size:
4-7/16" x 6-1/16" x 1"
Warranty:
3 Year Limited
Keyed:
Yes
Product Subgroup:
Mortise Locks and Trim
Product Type:
Electrified Mortise Locks
Commercial/Residential:
Commercial
Electronic:
Yes
Lock Type:
Mortise
Power:
400mA
Lock Function:
Double Cylinder
IMAP Policy:
Yes
Product Attribute:
Mortise Locks
Product Model:
L9095EL
Collection:
L9000 Series
Product Voltage:
12/24VDC
Product Function:
Double Cylinder
Door Hand Direction:
Field Reversible
Door Thickness Range:
1-3/4"
Product Category:
Mechanical Locks
Product Substrate:
CRS with Zinc Dichromate Plating
Department:
Door Hardware

Schlage L9095ELP 17A 626 – Frequently Asked Questions

1) Will the Schlage L9095EL unlock the door if the power goes out?
Yes, that's the whole point of the EL suffix. On the L9095EL both levers are held locked electrically, and a switch failure or power loss releases both levers so anyone can retract the latchbolt and get through. That makes it fail safe, which is what you want on egress-critical openings tied to a fire alarm or access control release. If you need the opposite behavior (locked on power loss), the same lock body is customer-selectable to EU, which locks both levers when power drops.
2) What voltage and current does the Schlage L9095EL electrified mortise lock need?
It runs on 12 or 24 VDC and auto-detects which one it's getting, so you don't order a voltage-specific version. Current draw is 400mA. Size your power supply and any door loop wire for that at the voltage you're feeding it, and remember this is a continuous-duty locked condition on EL, so the draw is there whenever the door is secure.
3) What size mortise pocket does the Schlage L9095EL need in the door?
The lock case measures 4-7/16 x 6-1/16 x 1 inches, so the door has to be prepped for a full L9000 mortise pocket. That case size is the same family footprint used across the L Series, which is why an existing L9000 prep will normally take this electrified body. If the door is currently prepped for a cylindrical or tubular lock, it needs a new mortise cut, not an adapter.
4) Do I have to order a Schlage L9095EL handed, left or right?
No handing needed on the order for the lock itself. The L9095EL is field reversible, so the same lock covers a left hand or right hand opening and you set it on site. The one place handing does come up is lever style: the 12 Lever is ordered as a specific left hand or right hand design, while the 01, 02, 03, 05, 06, 07, 17 and Omega levers are not called out that way.
5) Will the Schlage L9095EL latch into the strike that's already in my frame?
It ships with a 10-072 strike, 1-1/4 x 4-7/8 inches, square corner, with a box and a 1-3/16 inch lip. The latch is a 3/4 inch stainless steel latchbolt with an anti-friction tongue. If your existing frame cutout is that square corner 1-1/4 x 4-7/8 pattern, the supplied strike drops straight in. A radius corner frame prep or an ANSI 4-7/8 curved lip strike won't line up with the square corner unit, so plan on either the frame being cut for it or specifying a different strike.
6) Can you still get in with a key if the access control system is down on an L9095EL?
Yes. Double cylinder override means there's a cylinder on both sides and either key retracts the latchbolt regardless of what the electrified side is doing. That's the mechanical bypass a locksmith or facilities crew relies on when the panel, the reader, or the power supply is out. An auxiliary latch deadlocks the latchbolt whenever the door is closed, so the door can't be loided while it sits on key control.
7) What cylinder and keyway comes standard on the Schlage L9095EL, and can I get it less cylinder?
Standard build is two conventional 6-pin cylinders in the Schlage C keyway, ordered keyed different or keyed alike across a group of locks. If your building runs a restricted or proprietary key system, order the L option, less cylinder, and drop in your own cores. A UL437 listed cylinder is available by specifying a Primus 20-500 Series cylinder instead. One thing to know before standardizing: with interchangeable core cylinders the assembly carries Grade 2 security, while a concealed shell cylinder holds A156.13 Grade 1 operational and security.
8) Is the Schlage L9095EL approved for a 3-hour fire rated door?
Yes. L Series mortise locks are UL listed for 3-hour fire doors, with the exceptions being the L9076 and L9077 functions, and the L9000 is tested and certified to ANSI/BHMA A156.13 Grade 1 for both security and operational. UL/cUL listing covers A label single doors up to 4 x 10 feet and pairs up to 8 x 10 feet, and you can verify a given lock in the field by the letter F and the UL symbol stamped on the latch front. The electrified functions are additionally UL19X listed for single-point locking.
9) Does the Schlage L9095EL meet ADA and Buy American requirements for a government or school job?
Both are covered. The L Series meets ADA requirements and meets the Buy American Act, and it also carries Miami-Dade NOAs and Florida Building Commission listings if you're specifying into a coastal jurisdiction. For California work, any lever with a return to door of 1/2 inch (64 mm) or less complies with the California Referenced Standards Code, so the lever design you pick matters on that one, not the lock body.
10) What is the closest equivalent to a Schlage L9095EL if I need fail safe electric unlocking on both levers?
The Schlage L9095EL is an electrified mortise lock that continuously locks (EL) or unlocks (EU) both the inside and outside lever by 12 or 24V DC, with the latchbolt retracted by key from either side, and it is field reversible for either hand. The nearest peer that works the same electric-unlock way is the Command Access LPM190-M-EU-CH, a 24V motorized mortise lock with electric unlock and optional REX. The difference to check before you swap: the LPM190-M-EU-CH is a storeroom function chassis, so the outside lever is the controlled side and there is no double cylinder key override on both faces the way the L9095EL provides. The DynaLock EML-1 is likewise a storeroom function electrified mortise lock. If the opening needs key retraction from inside and outside, the L9095EL function is the one that matches.
11) Can I use a Command Access LPM110ECH in place of a Schlage L9095EL?
They solve different problems. The Command Access LPM110ECH is an electrified latch retraction mortise lock chassis running on 24VDC - it pulls the latchbolt back so the door can be pushed or pulled open remotely. The Schlage L9095EL does not retract the latch electrically; it locks or unlocks both levers by 12 or 24V DC, and the latchbolt is retracted by key or by turning the lever. If the opening is tied to an automatic operator or a remote release that has to free the door without anyone touching the lever, latch retraction is what you want, and the SDC 7600 Series is a Grade 1 motorized latch retraction mortise lockset with 24VDC control that does the same job. If access control simply needs to permit or deny the lever, the L9095EL function applies.
12) My access control panel only outputs 24VDC - which of these mortise locks will run on it?
The Schlage L9095EL runs on 12 or 24VDC and draws 400mA, so a 24V panel powers it directly with no separate supply for the lock. Comparable 24V units include the Command Access LPM110ECH, an electrified latch retraction chassis with 24VDC operation, the Command Access LPM190-M-EU-CH 24V motorized mortise lock with electric unlock, the SDC 7600 Series with 24VDC control, and the SDC Selectric 7800 PRO, a solenoid controlled mortise lock with a vandal resistant clutch. The L9095EL is the one of that group that accepts 12V as well, which matters if the same lock has to land on a 12V panel elsewhere in the building.
13) I need the lock to stay locked when power drops instead of releasing - can I still use the L9095EL?
Yes. The Schlage L9095EL is customer-selectable between EL and EU: as EL, a switch or power failure unlocks both levers and the lever will retract the latchbolt; as EU, a switch or power failure locks both levers. So the fail secure behavior is a setting on the same lock rather than a different part number. Among the peers, the Command Access LPM190-M-EU-CH is built as an electric unlock unit, and the Command Access ML04EU is an institutional function chassis. Confirm with the fire and life safety requirement for the opening before choosing which way to set it, since egress doors usually dictate the answer.
14) Can I get door position and request-to-exit monitoring built into this Schlage electrified mortise lock instead of adding separate switches?
Yes, and that's usually the cheaper way to wire an opening. Schlage's electrified L Series locks offer RX (request to exit), DPS (door position switch), latchbolt monitor and deadbolt monitor as options in the lock itself, which saves you running a separate door contact and REX device on the same leaf. Call the monitoring you need out on the order, since the base L9095EL configuration is the fail safe locking function with double cylinder override, not the monitored build.
15) How do I match a new electrified mortise lock to the levers and finishes already on my other doors?
The L9095EL is ordered in 10 finishes, from 605 bright brass and 606 satin brass through 613 oil rubbed bronze, 622 matte black, 626 satin chrome, 630 satin stainless and 643E aged bronze. Lever designs run 01, 02, 03, 05, 06, 07, 12, 17 and Omega, on an A or B wrought rose, an L full face escutcheon, or an N escutcheon. If your building already runs Von Duprin exit devices, all L Series levers suite with them, and they also suite with the LE, LM9200, LM9300 and LT products, so one lever design and finish can carry across the whole opening set.
16) What's the difference between a fail safe electrified mortise lock like the L9095EL and a storeroom function electrified mortise lock?
Different jobs. The L9095EL controls both levers electrically and drops unlocked on power loss, so it's for openings where access control decides who gets in and egress or free access has to survive a power failure. A storeroom function lock keeps the outside lever locked at all times and is unlocked by key or by an electric release, with the inside lever always free. If storeroom is what your opening actually calls for, ZenSupply carries the Command Access ML1080LB heavy-duty storeroom mortise chassis, the DynaLock EML-1 electrified mortise lock in storeroom function, and the Command Access LPM190-M-EU-CH, a 24V motorized storeroom lock with electric unlock and optional REX.
17) What else could I buy instead of a Schlage L9095EL for a 24V access controlled mortise opening?
A few real alternatives sit in the same slot. The SDC 7600 Series is a Grade 1 motorized latch retraction mortise lockset with 24VDC control, rated for 1-3/4 inch doors, the same thickness as the L9095EL. The SDC Selectric 7800 PRO is a solenoid controlled mortise lock with a vandal resistant clutch, also 1-3/4 inch. From Command Access, the LPM110ECH is a heavy-duty electrified latch retraction mortise chassis on 24VDC. The key difference to weigh: those run 24V, while the Schlage auto-detects 12 or 24VDC, so it drops onto an existing 12V supply without a new power source.
18) Is a mortise lock chassis from Command Access or DynaLock a straight swap for a Schlage L9095EL?
Not necessarily, and it's worth checking before you order. Products like the Command Access ML04EU institutional function chassis and the LPM110ECH are sold as lock chassis, meaning the body itself, where the L9095EL is ordered as a complete lockset with lever, rose or escutcheon, two 6-pin cylinders and a 10-072 strike. If you already have Schlage L Series trim on the door and only the lock body has failed, a chassis is what you want. If you're doing a full opening, the complete lockset saves you sourcing trim separately.
19) How durable is the Schlage L9095EL for a high traffic entrance, and can the lever be pulled off to defeat it?
It's a heavy duty commercial lock, built on a cold rolled steel case with zinc dichromate plating, and it exceeds ANSI/BHMA Grade 1 security and operational standards. A security blocking hub prevents picking the lock by removing the levers, and a locking lever bushing means there are no exposed screws on the inside levers. For abuse-prone openings, the Vandlgard free-wheeling outside trim option is available on most functions including electrified ones, so a forced lever spins instead of transferring load into the lock case.
20) I need several Schlage electrified mortise locks to open with the same key. How do I order that?
Order them keyed alike (KA) rather than keyed different. Keyed different is the standard build, so a group of locks arriving on separate keys is what you get if you don't say otherwise. If you're matching an existing master key system or a restricted keyway, use the special cylinder and keying requirements field to give the system details, or take the locks less cylinder and pin your own cores in the Schlage C keyway prep.
21) What should I specify instead of a Schlage L9095EL for a behavioral health or detention opening?
The Schlage L9095EL is a double cylinder electrified mortise lock built for standard commercial openings on 1-3/4 inch doors. For asylum, institution, and utility function openings, the Command Access ML04EU is an institutional function electrified mortise lock chassis, heavy-duty, purpose-built for that function. Institutional function changes how the lever behaves on the secured side in a way a double cylinder function does not replicate, so specify by function rather than substituting the L9095EL into that opening.
22) I am replacing an electrified mortise lock on a high traffic door that keeps getting the lever forced - what are my options?
Two directions. The Schlage L9095EL is a Grade 1 heavy duty mortise lock with a CRS body with zinc dichromate plating and a 3/4 inch stainless steel latch with anti-friction tongue, and Vandlgard free-wheeling outside trim is offered on most functions including electrified, which lets the outside lever spin freely when locked instead of taking the force. The SDC Selectric 7800 PRO Series is a solenoid controlled mortise lock with a vandal resistant clutch built for the same abuse and fits 1-3/4 inch doors. Both address forced lever torque; the L9095EL adds the double cylinder key override on both faces.
23) Is a Command Access chassis the same thing as ordering a complete Schlage L9095EL lockset?
No, and this catches people on takeoff. The Command Access ML1080LB, ML04EU, and LPM110ECH are mortise lock chassis - the lock body itself. A Schlage L9095EL is ordered as a complete lockset: you select the lever style from options including the 01, 02, 03, 05, 06, 07, 12 and 17 levers and the Omega, the rose or escutcheon design in A and B wrought rose, L full face escutcheon and N escutcheon, the finish, and the cylinder, which is standard as a conventional 6-pin C keyway cylinder, keyed different or keyed alike. If you are quoting a chassis against an L9095EL, add trim, cylinder and finish to the chassis side before comparing the two.
24) Can I add an occupancy indicator to a Schlage L9095EL for a restroom or behavioral health opening?
The L Series offers an exclusive 180 degree visibility indicator, so occupancy or locked status reads from a wide angle down the corridor rather than only head on. Also available across the series: tactile warning, anti-microbial coatings, and the Gold Standard ligature resistant trim developed for behavioral health applications. Those are option calls made when the lock is ordered, not field add-ons.
How fast can I get the Schlage L9095ELP 17A 626 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Schlage L9095ELP 17A 626 come with a warranty?
Absolutely. The Schlage L9095ELP 17A 626 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Schlage L9095ELP 17A 626?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Schlage L9095ELP 17A 626 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.

Videos