BEA FALCON EX XL Motion Sensor with Explosion-Proof Housing and 100ft Cable
Explosion-Proof Microwave Motion Detection for Hazardous Environments
The BEA FALCON EX XL combines advanced microwave Doppler radar technology with explosion-proof and flame-proof housing, specifically engineered for hazardous industrial environments including chemical manufacturing, petroleum refining, and agricultural facilities. This low-mounting sensor operates from 6½ feet to 11½ feet mounting heights and includes a 100ft cable for flexible installation. The NEMA 4X waterproof enclosure achieves UL Class I, Div. 1, Groups B, C, D; Class II, Div. 1 & 2, Groups E, F, G; and Class III certifications with IP66 housing protection.
Professional Features & Benefits
- Low Mounting Height Range: Designed for 6½ feet to 11½ feet mounting heights, ideal for lower ceiling industrial applications.
- Explosion-Proof Certification: UL Class I, Div. 1, Groups B, C, D; Class II, Div. 1 & 2, Groups E, F, G; and Class III certified for hazardous location compliance.
- Microwave Doppler Radar Technology: Advanced radar detection provides reliable motion sensing in challenging industrial environments with superior performance over traditional sensors.
- Extended Cable Length: Includes 100ft cable for flexible installation positioning and remote mounting capabilities in large industrial spaces.
- Weatherproof Construction: NEMA 4X waterproof rated enclosure with IP66 housing protection ensures reliable operation in harsh environmental conditions.
- Flexible Power Options: Compatible with 12 to 24V AC/DC power supply for integration with various industrial control systems.
- Industrial Application Focus: Specifically designed for chemical manufacturing, petroleum refining, and agricultural environments where explosion-proof equipment is required.
Technical Specifications
- Technology: Microwave Doppler Radar
- Radiated Frequency: 24.150 GHz
- Transmitter Radiated Power: < 20 dBm EIRP
- Radiated Power Density: < 5 mW / cm2
- Detection Mode: Motion
- Detection Zone (W x D): Falcon EX 100: 156 x 192 in (13 x 16 ft) @ 192 in | Falcon EX XL 100: 156 x 78 in (13 x 6.5 ft) @ 98.4 in | Falcon EX W 100: 360 x 132 in (30 x 11 ft) @ 252 in
- Tilt Angles: -90 deg. - 30 deg. in elevation
- Output: Relay (free of potential change-over contact)
- Max. Contact Voltage: 42 VAC / VDC
- Max. Contact Current: 1 A (resistive)
- Max. Switching Power: 30 W (DC); 60 VA (AC)
- Minimum Detection Speed: 2 in / s
- LED Signals: Green: Value indication | Red: Detection state & parameter indication
- Mains Frequency: 50 - 60 Hz
- Supply Voltage: 12 - 24 VAC; +/-10% | 12 - 24 VDC; 30% / -10%
- Maximum Power Consumption: < 2 W
- Mounting Height: Falcon EX 100: 138 - 276 in (11.5 - 23 ft) | Falcon EX XL 100: 78 - 138 in (6.5 - 11.5 ft) | Falcon EX W 100: 138 - 252 in (11.5 - 21 ft)
- Dimensions (Housing & Bracket): 7.5 in (W) x 5.5 in (H) x 9 in (D)
- Electrical Access NPT Pipe Thread: 3/4 in
- Weight: 11 lbs
- Cable Length: 100 ft or 30 ft
- Housing / Bracket Material: Copper-free Aluminum / Aluminum
- Temperature Range: -22 deg. F - 140 deg. F
- Degree of Protection: UL Class I, Div. 1, Groups B,C,D; Class II, Div. 1&2, Groups E,F,G; Class III; CENELEC: EExd IIC; NEMA 4X, IP66
- Norm Conformance: R&TTE: 1999/5/EC; EMC: 2004/108/EC
Installation & Operation
- Verify electrical requirements match available power supply. Confirm 12 to 24V AC/DC voltage and current capacity before proceeding.
- Disconnect power supply before beginning installation. Follow all applicable electrical codes and safety procedures for hazardous locations.
- Mount the unit at the specified height between 6½ feet to 11½ feet ensuring adequate clearance for wiring access, ventilation, and future service requirements.
- Route and connect the 100ft cable according to manufacturer wiring diagrams using explosion-proof conduit and fittings appropriate for the hazardous classification.
- Configure operational settings per application requirements and verify proper detection field coverage.
- Restore power and test all functions including normal operation, detection sensitivity, and integration with connected access control systems.
- Complete final inspection and document settings. Refer to manufacturer documentation for complete wiring diagrams, programming instructions, and troubleshooting.
Professional Applications
- Chemical Manufacturing Facilities
- Petroleum Refining Operations
- Agricultural Processing Plants
- Pharmaceutical Production Areas
- Paint and Coating Manufacturing
- Grain Handling and Storage Facilities
- Industrial Solvent Processing Areas
Explosion-Proof Design
The FALCON EX XL features a specialized explosion-proof and flame-proof housing that meets stringent UL classifications for multiple hazardous location groups. The NEMA 4X enclosure provides complete protection against water ingress while maintaining the explosion-proof integrity required for Class I, II, and III hazardous locations across Groups B through G.
Why Choose BEA Quality?
BEA FALCON EX motion sensors deliver professional-grade reliability with explosion-proof construction certified for the most demanding hazardous industrial environments. The microwave Doppler radar technology and NEMA 4X weatherproof housing ensure dependable performance in chemical manufacturing, petroleum refining, and agricultural applications where safety and reliability are paramount.
Manufacturer Resources
Product Specs
- Product Type:
- Motion Sensor
- Series:
- FALCON EX
- Subcategory:
- Sensors, Switches, Relays and Timers
- Commercial/Residential:
- Commercial
- Electronic:
- Yes
- Product Group:
- Electronic Access Controls
- Product Subgroup:
- Sensors, Switches, Relays and Timers
- Mounting Height:
- Low
- Technology:
- Microwave Doppler Radar
- Collection:
- FALCON EX
- Product Category:
- Electronic Access Control
- Department:
- Door Hardware