HES 1006CAS Complete Electric ...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$906.88
$517.76

HES 1006CAS Complete Electric Strike for Deadbolt Locks with Continuous Recapture

(No reviews yet) Write a Review

Model: 1006CAS-630

In Stock (leaves warehouse same day if ordered before 3pm ET)

$906.88
$517.76
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
✨
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

HES 1006CAS COMPLETE ELECTRIC STRIKE PAC FOR DEADBOLT LOCKS

The 1006C Smart Strike is the strongest and most versatile electric strike available. This Complete One Box Solution includes all hardware necessary to fully accommodate any brand of cylindrical or mortise lockset that works with an ANSI 4-7/8" strike plate. It is the only electric strike that can release, recapture and contain mortise locks with a 1" deadbolt. The 1006CS is truly in a class of its own.

Frame application

  • Metal
  • Wood

Electrical

  • .45 Amps at 12VDC* continuous duty
  • .25 Amps at 24VDC* continuous duty
  • *Note: DC must be well filtered with ripple less than 1 volt RMS.

FEATURES AND BENEFITS

Standard Features

  • Stainless steel construction
  • Tamper resistant
  • Static strength 2,500 lbs. (fail secure)
  • Dynamic strength 350 ft-lbs. (fail secure)
  • Endurance 1,000,000 cycles
  • Fail secure (standard)
  • Dual voltage 12 or 24VDC continuous duty
  • Non-handed
  • Internally mounted solenoid
  • Accommodates up to 1" deadbolt
  • Plug-in connector
  • Full keeper shims for horizontal adjustment
  • Trim enhancer
  • Five year limited warranty

Optional Features

  • Fail Safe

Finishes

  • 630 - Satin stainless steel

FACEPLATES and ACCESSORIES

Faceplate Options

  • J (4-7/8" x 1-1/4") For use with cylindrical locksets up to 3/4" throw and all locksets with center-lined bolts. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • E (4-7/8" x 1-1/4") For use with Corbin/Russwin Security Bolt, Weiserbolt, and normally extended 1" tubular deadbolts. ANSI/BHMA Numbers: #E09391, #E09392, #E09393
  • K (4-7/8" x 1-1/4") For use with Mortise locksets with a deadlatch positioned above the latchbolt. Compatible Locksets: Baldwin, Marks, PDQ, Others. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • KD (4-7/8" x 1-1/4") For use with Mortise locksets with a deadlatch positioned above the latchbolt. Compatible Locksets: Jackson, Sargent (7700 and 8100), Schlage, Yale (8700). ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • KM (4-7/8" x 1-1/4") For use with Mortise locksets with a deadlatch positioned below the latchbolt. Compatible Locksets: Accurate, Arrow, Best*, Corbin/Russwin, Falcon (1992 M Series), Sargent (7800, 8200 and 9200 series), Yale (8800) *For Best 45H andâ€47H deadlatch below, and Best 34H - 37Hâ€deadlatch above. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • N (4-7/8" x 1-1/4") For use with Mortise locksets where the deadbolt is used for night-latch function only. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • ND (4-7/8" x 1-1/4") For use with Mortise locksets where the deadbolt is used for night-latch function only. Compatible Locksets: Sargent (7700 and 8100 series), Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • NM (4-7/8" x 1-1/4") For use with Mortise locksets with a deadlatch positioned below the latchbolt and where the deadbolt is used for night-latch function only. Compatible Locksets: Best (45Hâ€andâ€47H, and 34H-37H), Corbin/Russwin, Falcon, Sargent (7800, 8200 and 9200 series). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • A (4-7/8" x 1-1/4") For use with Mortise locksets with a normally extended 1" deadbolt without a deadlatch. Compatible Locksets: Arrow, Baldwin, Marks, Omnia, PDQ, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • AD (4-7/8" x 1-1/4") For use with Mortise locksets with a normally extended 1" deadbolt without a deadlatch. Compatible Locksets: Sargent (7700 and 8100 series), Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • AM (4-7/8" x 1-1/4") For use with Mortise locksets with a normally extended 1" deadbolt and a deadlatch positioned below the latchbolt. Compatible Locksets: Accurate, Best (45Hâ€andâ€47H, and 34H-37H), Corbin/Russwin, Falcon, Sargent (7800, 8200, and 9200 series), Yale (8800). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • T (4-7/8" x 1-1/4") For use with Mortise locksets with a normally extended 1" deadbolt and a center-lined deadlatch. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • TD (4-7/8" x 1-1/4") For use with Mortise locksets with a normally extended 1" deadbolt and a center-lined deadlatch. Compatible Locksets: Sargent (7700 and 8100 series), Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • H (4-7/8" x 1-1/4") For use with Mortise locksets with a 1" deadbolt without a deadlatch. Strike will not release when deadbolt is extended. Compatible Locksets: Arrow, Baldwin, Marks, Omnia, PDQ, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • HD (4-7/8" x 1-1/4") For use with Mortise locksets with a 1" deadbolt without a deadlatch. Strike will not release when deadbolt is extended. Compatible Locksets: Sargent (7700 and 8100 series), Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • HM (4-7/8" x 1-1/4") For use with Mortise locksets with a 1" deadbolt with a deadlatch positioned below the latchbolt. Strike will not release when deadbolt is extended. Compatible Locksets: Accurate, Best (45Hâ€andâ€47H, and 34H-37H), Corbin/Russwin, Falcon, Sargent (7800, 8200, and 9200 series), Yale (8800). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • HT (4-7/8" x 1-1/4") For use with ASSA model 504 mortise lockset with two latchbolts and a center deadlatch. Deadlatch or mortise locksets with a 1" deadbolt and a center-lined deadlatch. Strike will not release when deadbolt is extended. Compatible Locksets: ASSA. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • HTD (4-7/8" x 1-1/4") For use with Mortise locksets with a 1" deadbolt and a center-lined deadlatch. Strike will not release when deadbolt is extended. Compatible Locksets: Sargent (7700 and 8100 series), Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • R (4-7/8" x 1-1/4") For use with a hookbolt up to 1" throw. Compatible Locksets: Adams Rite, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • Z (4-7/8" x 1-1/4") For use with unit and mono locks. Compatible Locksets: Unican, Sargent, Corbin-Russwin. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • J2 (9" x 1-3/8) For use with cylindrical locksets with up to a 3/4" throw, in wood frame applications. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • K2 (9" x 1-3/8") For use with Mortise locksets with a deadlatch positioned above the latchbolt, in wood frame applications. Compatible Locksets: Baldwin, Marks, PDQ, Others. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • KM-2 (9" x 1-3/8") For use with Mortise locksets with a deadlatch positioned below the latchbolt, in wood frame applications. Compatible Locksets: Accurate, Arrow, Best*, Corbin/Russwin, Falcon (1992 M Series), Sargent (7800, 8200 and 9200 series), Yale (8800). *For Best 45H andâ€47H deadlatch below, and Best 34H - 37Hâ€deadlatch above. ANSI/BHMA Numbers: #E09321, #E09322, #E09323
  • N-2 (9" x 1-3/8") For use with Mortise locksets where the deadbolt is used for night-latch function only, in wood frame applications. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage, Yale (8700), Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • T-2 (9" x 1-3/8") For use with Mortise locksets with a normally extended 1" deadbolt and a center-lined deadlatch, in wood frame applications. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage, Yale (8700), Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • A-2 (9" x 1-3/8") For use with Mortise locksets with a normally extended 1" deadbolt without a deadlatch, in wood frame applications. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage, Yale, Others. ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333
  • H-2 (9" x 1-3/8") For use with Mortise locksets with a 1" deadbolt without a deadlatch, in wood frame applications. Strike will not release when deadbolt is extended. Compatible Locksets: Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Yale (8700). ANSI/BHMA Numbers: #E09391, #E09392, #E09393, #E09331, #E09332, #E09333

 

Accessories

  • 1000-102 - Rain guard
  • 1006-103 - Full keeper shims
  • 1000-104 - Lip extension trim adapter
  • 1006-105 - Trim enhancer BLK (goof plate)
  • 1006-109 - Trim adapter
  • 1000-110 - Replacement strike plate
  • 1000-130 - KD filler plate
  • HESCUT-MTK Metal template kit
  • 2001M - Plug-in bridge rectifier
  • 2004M - ElectroLynx® adapter
  • 2005M3 - SMART Pac III™
  • 2006M - Plug-in buzzer

 

CERTIFICATIONS and LISTINGS

  • UL 10C fire-rated, 3 hour single door (fail secure only)
  • UL 10C fire-rated, 1-1/2 hour double door (fail secure only)
  • CAN4-S104(ULC-S104) fire door conformant
  • ANSI A250.13-2003 windstorm listed
  • UL 1034 burglary-resistant listed and suitable for outdoor use
  • UL 294 listed
  • ANSI/BHMA A156.31, Grade 1
  • NFPA-252 fire door conformant
  • ASTM-E152 fire door conformant
  • Florida Building Code approved
  • Patents #6,021,038 and 6,595,564, 9,183,976 and 9,449,747

 

Product Specs

Subcategory:
Electric Strikes
Product Group:
Electronic Access Controls
Series:
1006 Series
Grade:
Grade 1
Shim:
Horizontally Adjustable
Dynamic Strength:
350 ft-lbs
Warranty:
5 Year (10 Year when SmartPACIII)
Endurance Cycles:
1,000,000
Product Subgroup:
Electric Strikes
Product Type:
Electric Strikes for Deadbolts
Door Type:
Metal, Wood
Lock Type:
Mortise or Cylindrical
Windstorm Rated:
Yes
Commercial/Residential:
Commercial
Electronic:
Yes
Lock Function:
Deadbolt
Fail-safe / Fail-secure:
Field Selectable
Holding Force:
2500
Product Model:
HES-1006CS
Product Voltage:
12/24 VDC
Product Function:
Deadbolt
Face Plate:
4-7/8"
Fire Rating:
Yes
Latch Specification:
Latchbolt
Door Strike:
1-11/16"
Product Substrate:
Stainless Steel
Product Category:
Electronic Access Controls
Product Width:
1-11/16"
Department:
Door Hardware
Product Depth:
2-1/16"

HES 1006CAS-630 – Frequently Asked Questions

1) Will the HES 1006CAS electric strike work with a mortise lock that has a 1 inch deadbolt?
That's exactly what the 1006C Smart Strike is built for. It accommodates a deadbolt up to 1 inch, and it will release, recapture and contain a mortise lock with a 1 inch deadbolt rather than just holding a latchbolt. Which faceplate you use decides the behavior: the A, AD and AM plates suit a normally extended 1 inch deadbolt, while the H, HD, HM, HT and HTD plates are for 1 inch deadbolts where the strike will not release while the deadbolt is thrown. Pick the plate to match your lock's deadlatch position (above, below, or center-lined with the latchbolt).
2) What faceplates come in the box with the HES 1006CAS, and do I have to order others separately?
Two package choices are sold. The standard pack ships with the ND and NM faceplates, and the other pack ships with the N-2 faceplate. All three are night-latch plates, meaning the deadbolt is used for night-latch function only: ND fits Sargent 7700 and 8100 and Yale 8700 mortise locks, NM fits Best 45H/47H and 34H-37H, Corbin/Russwin, Falcon and Sargent 7800, 8200 and 9200, and the N-2 is the 9 x 1-3/8 inch plate for wood frame applications covering Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage and Yale 8700. If your lock needs a different plate, say a T for a center-lined deadlatch or an R for an Adams Rite hookbolt, that plate is ordered on its own.
3) Is the HES 1006 strike fail safe or fail secure, and do I pick that when I order?
Both are offered as separate orderable versions, and the strike itself is field selectable between the two. Fail secure is the standard configuration, and it is the only one carrying the fire rating: the UL 10C 3 hour single door and 1-1/2 hour double door listings apply to fail secure only. The published strength numbers, 2,500 lbs static and 350 ft-lbs dynamic, are also fail secure figures. If the opening is a fire door, order fail secure. Fail safe (unlocked on power loss) is the right choice only where egress or a life-safety sequence requires the strike to release when power drops.
4) Does the HES 1006 electric strike fit a standard ANSI 4-7/8 inch strike prep?
Yes. The faceplate is 4-7/8 inches, so it drops into the standard ANSI 4-7/8 inch strike cutout, and the included hardware covers any brand of cylindrical or mortise lockset that works with that prep. Body depth into the frame is 2-1/16 inches and the strike width is 1-11/16 inches, so confirm your frame has that much clear depth behind the prep before you cut. For wood frames, the 9 x 1-3/8 inch plates (J2, K2, KM-2, N-2, T-2, A-2, H-2) are the wood frame versions.
5) Can I install an HES 1006 electric strike in a wood frame, or is it metal frames only?
Both. Metal and wood frame applications are covered. For wood, use one of the 9 x 1-3/8 inch faceplates, which are the ones specified for wood frame work: J2 for cylindrical locksets up to 3/4 inch throw, K2 and KM-2 for mortise locks by deadlatch position, N-2 for night-latch deadbolt function, T-2 for a normally extended 1 inch deadbolt with a center-lined deadlatch, A-2 for a normally extended 1 inch deadbolt with no deadlatch, and H-2 where the strike should not release with the deadbolt thrown. The longer plate gives you more wood to fasten into.
6) Can I put an electric strike on a fire rated door without voiding the label?
On a fire door you need a strike that is listed for it, and the 1006 is, in fail secure only: UL 10C fire rated for 3 hour single doors and 1-1/2 hour double doors, plus CAN4-S104 (ULC-S104), NFPA-252 and ASTM-E152 fire door conformance. A fail safe strike unlocks when power drops, which is why the fire rating does not extend to it. The same unit is ANSI/BHMA A156.31 Grade 1, UL 294 listed for access control, UL 1034 burglary resistant and suitable for outdoor use, ANSI A250.13-2003 windstorm listed, and Florida Building Code approved.
7) What power supply do I need for an HES 1006 strike, and can I run it on the same 12V supply as my access control panel?
The 1006 runs dual voltage, 12 or 24VDC, continuous duty, drawing .45 amps at 12VDC or .25 amps at 24VDC. Size your supply for that draw plus whatever else is on the circuit. One condition matters: the DC must be well filtered, with ripple under 1 volt RMS. A cheap or unfiltered supply, or an AC transformer feeding it raw, will buzz the solenoid and shorten its life. If you are feeding it from AC, the 2001M plug-in bridge rectifier is the HES accessory for that, and the connection at the strike is a plug-in connector rather than bare leads.
8) My existing strike cutout is a little off from where the lock bolt lands. Can the HES 1006 be adjusted?
There is horizontal adjustment built in. Full keeper shims (part 1006-103) let you move the keeper side to side so the keeper picks up the bolt cleanly instead of forcing you to re-cut the frame. Shims ship with the complete pac. If the old cutout leaves cosmetic damage around the new plate, the 1006-105 trim enhancer (goof plate) covers it, the 1000-104 lip extension trim adapter handles a frame that sits proud, and 1000-130 is a KD filler plate. For exterior openings the 1000-102 rain guard is the accessory to add.
9) Is the HES 1006 strike handed? Do I need to specify left or right hand?
Non-handed, so one part number covers both swings. That is useful if you are stocking spares for a building with doors swinging both ways, or if you are ordering before the opening is confirmed. What you do have to specify is the fail safe or fail secure version and the faceplate that matches your lockset.
10) Is an electric strike strong enough for an exterior entrance, or should I be looking at a maglock?
Strength on the 1006 is 2,500 lbs static and 350 ft-lbs dynamic in fail secure, with a 1,000,000 cycle endurance rating and stainless steel, tamper resistant construction. It is UL 1034 burglary resistant listed and suitable for outdoor use, and windstorm listed to ANSI A250.13-2003. Practical difference against a maglock: a fail secure strike stays locked when power drops and keeps the mechanical lock working as a lock, so the opening is still secure during an outage, and it does not require the door prep and life-safety release wiring a maglock does. For exterior use add the 1000-102 rain guard.
11) Is the HES 1006 rated for a high traffic entrance in an apartment building or school?
Grade 1 under ANSI/BHMA A156.31 with a 1,000,000 cycle endurance rating, stainless steel body, and commercial classification. That is the top grade in the electric strike standard and the cycle count is the number to hold against a main entrance or a school corridor door that gets hit all day. Non-handed construction means one part number standardizes across openings swinging either way, which matters when you are specifying for a whole facility.
12) What finish does the HES 1006 electric strike come in?
630 satin stainless steel, one finish across the line, matching the stainless steel body. 630 is the standard commercial finish, so it lines up with the satin stainless levers, exit devices and push plates already on most commercial openings without a special order.
13) Can I add a door buzzer or connect the HES 1006 to an ElectroLynx harness?
Both are catalogued accessories for the 1006. The 2006M is a plug-in buzzer, and the 2004M is the ElectroLynx adapter, which is what you want when the frame is already wired with an ElectroLynx quick-connect harness. Also available: the 2005M3 SMART Pac III for inrush and voltage management, the 2001M plug-in bridge rectifier for AC input, and the HESCUT-MTK metal template kit for cutting the frame. The strike terminates in a plug-in connector, so these attach without splicing at the strike.
How fast can I get the HES 1006CAS-630 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the HES 1006CAS-630 come with a warranty?
Absolutely. The HES 1006CAS-630 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the HES 1006CAS-630?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the HES 1006CAS-630 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.

Videos