Schlage ND82 Institutional Cyl...
IN STOCK (leaves warehouse same day if ordered before 3pm ET)
$1,167.00
$638.08

Schlage ND82 Institutional Cylindrical Lever Lock Grade 1

(No reviews yet) Write a Review

Model: ND82PD RHO 626
From the ND-Series Collection
$1,167.00
$638.08
Selected Finish is
Selected Lever Type is
Selected Cylinder is
Selected Keying is

In Stock (leaves warehouse same day if ordered before 3pm ET)

$1,167.00
$638.08
Adding to cart… The item has been added
Free Shipping on orders over $199
We price match and offer bulk discounts! Click Add to Quote. It's quick and easy.
Earn points with this purchase! You can redeem points for giftcards, iPads, XBox's and more. View Rewards
Free Keying on all locks

Default Attributes
Style:
Same lever, rose and finish for both sides of the door with coordinating latch and strike.
Latch: 13-247: 2-3/4" Backset-with 1-1/8" x 2-1/4" Square Corner Faceplate.
Strike: 10-025: 1-3/16" - Lip ANSI, No Box, 1-1/4" x 4-7/8".
Door thickness: 1-3/4".
Strike lip length: 1-3/16".
Keying (for P6, P and T cylinders): KD:Keyed different.
Keys (for P6, and P cylinders): Two nickel silver cut keys per lock.

 

Schlage ND82 - INSTITUTIONAL LOCKSET

Both levers fixed. Entrance by key in either lever. Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only

 

Schlage ND SERIES OVERVIEW

The Schlage ND Series offers a full breadth of commercial lock options with a suited combination of mechanical, electrified and electronic options. This overview covers common characteristics for the mechanical and electrified lock information.

Beyond grade 1 performance is the hallmark of the mechanical and electrified locks. ND Series locks are tested to withstand 3,100 in-lb. of abusive lever torque - more than 2 1/2 times the Grade 1 standard requirement. Offset lever pull testing up to 1,600 lbs. assures you of the lock's superb resistance against pry bar attacks. More than strong, ND Series is built to last and shows nearly zero droop or wobble after 16 million cycles.

All ND Series locks including electronic and ligature-resistant trim use the common cylindrical ANSI 161 door preparation making them easily interchangeable. They are ideal for all new construction and retrofit applications.

 

ND Series Mechanical Lock

The ND mechanical lock, along with being Schlage’s best selling mechanical lock, is the foundation for both the wired electrified and NDE wireless electronic lock. Not only did Schlage invent the cylindrical lock, but they continue to make it better with capabilities such as:

  • Unparalleled strength - the lock prevents access even when subjected to torque loads up to 3,100 in-lbs (2.6x BHMA1), withstands pry bar attacks of 1,600 lbs (8x BHMA requirements1), and withstands 100 hammer blows (20x BHMA requirements1, 2)
  • Exceptional durability - cycle tested to over 16M cycles (16x BHMA requirements1) with near zero droop or wobble - without the use of set screws or O-rings
  • Improved feel - improved strength and durability are more than numbers, you can actually feel it in the lock
  • Improved installation - installation is even easier than before (and withoutany set screws or O-rings)



FEATURES & BENEFITS

Security

  • Significantly exceeds ANSI/BHMA Grade 1 requirements
  • No access with minimum 3,100 in-lb. abusive lever torque, the equivalent of over 690 lbs. applied to the end of a 4-1/2" lever, 2.6 times over the BHMA requirement*
  • No access with minimum 1,600 lbs. offset lever pull for protection against pry bar attacks, 8 times over the BHMA requirement*
  • 5 points of engagement provide nearly zero droop and wobble after 16 million cycles, 16 times over the BHMA requirement*, without the use of set screws or o-rings
  • High security locking when used with Primus XP UL 437 listed cylinders

 

Function availability and convenience

  • 24 mechanical/4 electrified functions in the ND Series (custom functions available upon request)
  • Multiple key systems available: open, patented and restricted
  • Four electrified functions auto-detect 12/24V DC operation and, with maximum current draws of 0.4 amps and 0.1 amps holding current eliminate heated levers
  • Indicator roses for classroom applications
  • Three spring cage sets support all Schlage plus eight competitive cylinder formats

 

Aesthetics

  • Nine lever and four rose designs
  • Ten available finishes
  • Perfectly suited to Schlage ALX Series grade 2 locks
  • Suites with Von Duprin exit devices and other Schlage products

 

Options

  • Vandlgard™ models have a lever that freely rotates up and down when locked to protect the chassis from excessive force on the lever to prevent vandlism.

 

*Beyond Grade 1 performance for ND Series locks with Schlage cylinders only (Conventional, FSIC & SFIC). Performance with non-Schlage cylinders will exceed BHMA grade 1 requirements, but the product performance may be less than that of Schlage cylinders.

 

AVAILABLE ND SERIES FUNCTIONS

Other ND Series models can be found in the ND Series section and in-depth function description are available in the ND Series catalog linked below, or in the image carousel above.

Non-keyed functions

  • ND10 ANSI F75 Passage Lock
  • ND12 ANSI F89 Exit Lock (mechanical and electrified)
  • ND40 ANSI F76 Privacy Lock
  • Plus four additional functions

 

Keyed functions

  • ND50 ANSI F82 Entrance/Office Lock
  • ND53 ANSI F109 Entrance Lock
  • ND70 ANSI F84 Classroom Lock
  • ND80 ANSI F86 Storeroom Lock (mechanical and electrified)
  • Plus six additional functions

 

Special functions

  • ND30 ANSI F77 Patio Lock
  • ND72 ANSI F80 Communicating Lock
  • Plus five additional functions



CERTIFICATIONS & TESTING

To see all specifications and certifications, review the ND Series catalog in the links below.

Certifications

  • Tested and certified under ANSI/BHMA A156.2 Series 4000, Grade 1
  • UL/cUL listed: All locks 3-hour, A label fire door 4' x 10' single door and 8' x8' pair doors; 90-minute 8' x 10' pair doors with 3/4" latch option
  • Meets ADA requirements
  • Meets BAA (Buy American Act)
  • ANSI/BHMA Certifications: All ND Series comply with A156.2 performance requirements for grade 1 cylindrical locks. Wired electrified complies with A156.25 (indoor), wireless electronic complies with A156.25 (indoor/outdoor) requirements for electrified locking devices.
  • ICC Certifications: Complies with ICC A117.1 Accessible and Usable Buildings and Facilities.
  • UL/cUL Certifications: All locks 3 hour A label single firedoor 4'0" x 10'0"; pair doors 3 hour firedoor 8'0" x 8'0" with 3⁄4" latch option; pair doors 90 minute fire 8'0" x 10'0" with 3⁄4" latch option.
  • CA Fire Code Certifications: All levers with a return to door of 1⁄2" (64 mm) or less comply (Rhodes, Sparta, Tubular, Omega, Longitude, Boardwalk).
  • FL Building Code Certifications: Complies with Florida Building Code (ASTM E330, E1886, E1996) and Miami Dade (TAS 201, 202, 203) requirements for hurricanes.
  • Federal Certifications: Meets FF-H-106C Series 161.
  • Other Certifications: UL294, CSA C22.2 No. 205-M1983, FCC Part 15, IC RSS-210, RoHS.

 

Testing

  • ANSI Cycles Tested: 3 million cycles (3x ANSI grade requirement).
  • Abusive locked lever torque: Minimum 3,100 inch-pounds without gaining access.
  • Offset lever pull: Mminimum 1,600 foot pounds without gaining access.
  • Vertical lever impact: Minimum 100 impacts without gaining access.
  • Cycle life: Minimum 16 million cycles; 1) with no visible lever sag; 2) without the use of performance aids (i.e. set screws, spacers, etc.).



DOWNLOADS & RESOURCES



Technical resources

 

Manufacturer Resources

Product Specs

Series:
ND Series
Grade:
Grade 1
Duty Level:
Heavy Duty
Handle Type:
Lever
Keyed Function:
Double Cylinder
Keys Included:
2
Warranty:
10 Year
Standard Latch:
13-247: Deadlatch - 2-3/4" Backset - Square corner, 1-1/8" x 2-1/4"
Standard Strike:
10-025: ANSI, no box, 1-1/4" x 4-7/8" (1-3/16" Lip length)
Subcategory:
Cylindrical Lever Locks
ANSI/BHMA:
F87
Product Group:
Mechanical Locks
Product Subgroup:
Bored Locksets
Product Type:
Leversets
Keyed:
Yes
Electronic:
No
Commercial/Residential:
Commercial
Cylinder and Keyways:
S123
Function Description:
Both levers fixed. Entrance by key from either lever. Intended for asylum, institution, and utility applications. Not recommended for residential egress doors — verify compliance with local codes before specifying.
Lock Type:
Cylindrical
Lock Function:
Asylum/Institution/Utility
Product Attribute:
Cylindrical Locks
IMAP Policy:
Yes
Tags:
schlage nd82pd, nd82pd
Product Model:
ND82
Collection:
ND-Series
Product Function:
Asylum/Institution/Utility
Door Hand Direction:
Non-Handed
Product Category:
Mechanical Locks
Product Substrate:
Zinc and Steel
Department:
Door Hardware

Schlage ND82PD RHO 626 – Frequently Asked Questions

1) What does the Schlage ND82 lock function actually do, and is it legal on an exit door?
Both levers stay fixed at all times on the ND82, and the only way through is a key from either side. That is the ANSI F87 asylum/institution/utility function, a double cylinder arrangement. Because nobody can get out without a key, it should not go on a residential door or on any door used for egress in any building; that is a life safety hazard in an emergency. Use it on utility rooms, mechanical spaces, and institutional openings where code allows key-both-sides, and confirm against your local code before you specify it.
2) Will a Schlage ND82 fit my door, and what backset and prep does it need?
The ND82 is built for a 1-3/4 inch door and uses the standard cylindrical ANSI 161 door prep, so it drops into an opening already bored for a commercial cylindrical lock. The standard latch is the 13-247 deadlatch on a 2-3/4 inch backset with a 1-1/8 x 2-1/4 inch square corner faceplate. It is non-handed, so you do not specify hand when ordering. If your existing bore is on a 2-3/8 inch backset, the standard latch will not reach the strike.
3) Will the ND82 latch into the strike that's already in my frame?
The lock ships with the 10-025 ANSI strike, 1-1/4 x 4-7/8 inches with a 1-3/16 inch lip length and no box. If your frame is already cut for an ANSI 4-7/8 inch strike, which is the normal commercial frame prep, the supplied strike drops straight into that cutout. Frames prepped for a small T-strike or a residential full-lip strike will need the opening enlarged. Watch the lip length too: 1-3/16 inch suits a flush frame, and a deeper reveal or applied stop wants a longer lip so the latch is not catching the edge.
4) Which cylinder option should I order on a Schlage ND82, and what if my building is on small format interchangeable core?
Four cylinder choices, and since the ND82 is keyed on both sides the choice applies to both. PD is the conventional 6-pin cylinder in the Schlage C keyway, supplied with two nickel silver cut keys per lock, keyed different unless you order keyed alike. BD gives you the SFIC housing less the core, so your locksmith drops in the cores your facility already runs. JD is the Schlage full size interchangeable core prep, less core. LD is less cylinder entirely, for shops that supply their own. If you are standardized on an SFIC system, order BD and pin your own cores rather than taking PD and rekeying.
5) Does the Schlage ND82 meet ADA and can it go on a fire rated door?
ADA requirements are met, and the lock complies with ICC A117.1 for accessible and usable buildings. It is UL and cUL listed for 3 hour A label single fire doors up to 4 ft x 10 ft, and for 8 ft x 8 ft pairs at 3 hours or 8 ft x 10 ft pairs at 90 minutes with the 3/4 inch latch option. It also meets the Buy American Act and federal FF-H-106C Series 161. For California fire code, the levers with a 1/2 inch or less return to door comply: Rhodes, Sparta, Tubular, Omega, Longitude and Boardwalk.
6) What is the difference between the Schlage ND82 and an ND80 storeroom lock?
The ND80 storeroom function, ANSI F86, keeps the outside lever locked and the inside lever always free to exit. The ND82 has no free side: both levers are fixed and a key is needed from either direction. Storeroom is what you want on almost any door people occupy or pass through, because egress is unimpeded. The ND82 is only for the narrow case where the room must be secured against exit as well as entry, such as a utility or institutional application, and where code permits it. Both share the same Grade 1 ND chassis and the same ANSI 161 prep, so switching between them later is a chassis swap, not a door rework.
7) What else could I buy instead of a Schlage ND82 asylum lock?
The closest cross-brand equivalent ZenSupply carries is the Dexter C1000 Series asylum lock, also Grade 1 F87 function, and it is listed for a 1-3/8 to 2 inch door thickness range rather than the ND82's single 1-3/4 inch. If your openings vary in thickness, that range matters. Arrow's MK33-BD-CS is another asylum/institution function lock, heavy duty, with a conventional cylinder in the Schlage C keyway, though it is a ball knob rather than a lever, so it will not satisfy an accessibility requirement the way a lever does.
8) My doors are thicker than 1-3/4 inches. Can I still use a Schlage ND82?
No. The ND82 is specified at a 1-3/4 inch door thickness, which is the standard commercial door. For an opening at 2 inches or a thin 1-3/8 inch door, look at a lock published with a range: the Dexter C1000 asylum lock covers 1-3/8 to 2 inches for the same F87 function, and the Falcon K101 Grade 1 cylindrical covers 1-3/8 to 2-1/4 inches, though that one is a passage function with no keying at all.
9) Can I put a Schlage ND82 in place of an existing cylindrical lock without redoing the door?
In most cases yes. Every ND Series lock, including the electronic and ligature resistant trim versions, uses the common cylindrical ANSI 161 door preparation, so they are interchangeable with each other and go into new construction or retrofit openings alike. What you need to confirm on the door in front of you is the 2-3/4 inch backset for the standard 13-247 latch, the 1-3/4 inch thickness, and that the frame is cut for the 4-7/8 inch ANSI strike.
10) The double cylinder function is not allowed on my egress door - what Grade 1 lever should I use instead?
For an egress opening, a storeroom or classroom function is the usual substitution. The Dexter C1000 Series classroom lever is Grade 1, keyed and clutching, for 1-3/8 inch to 1-3/4 inch doors, and the Dexter C1000 classroom security model is Grade 1 in the same thickness range. Within the Schlage ND family, the ND80 is the ANSI F86 storeroom function and the ND70 is the ANSI F84 classroom function. The ND82 keys from both sides with both levers fixed, which is why it is not recommended on doors used for egress.
11) Can I get several ND82 locks keyed alike on one key?
Keying is a required selection. Keyed different is standard, so each lock arrives on its own key with two cut keys. Choosing keyed alike puts a group of locks on one key, which is what you want when a maintenance crew carries a single key for a run of utility or mechanical rooms. There is also a free text field for special cylinder and keying requirements if the locks need to go onto an existing master system. Selecting no keying is how you order the less cylinder configurations.
12) Is a Schlage ND82 tough enough for a high abuse institutional opening?
This is heavy duty, ANSI/BHMA A156.2 Series 4000 Grade 1 certified, in zinc and steel. Schlage rates the ND chassis to hold at 3,100 in-lb of abusive lever torque, resist 1,600 lbs of offset lever pull against pry bar attack, and take 100 vertical lever impacts without granting access. Cycle life is 16 million with near zero lever droop and no set screws or O-rings holding the lever on. Those beyond Grade 1 numbers apply with Schlage cylinders; with a non-Schlage cylinder the lock still exceeds BHMA Grade 1 but performance may be lower.
13) Which lever style and finish should I pick to match the other Schlage locks in my building?
Nine lever designs are offered: Athens, Boardwalk, Broadway, Latitude, Longitude, Omega, Rhodes, Sparta and Tubular. Finishes run to ten: 605 bright brass, 606 satin brass, 612 satin bronze, 613 oil rubbed bronze, 619 satin nickel, 622 matte black, 625 bright chrome, 626 satin chrome, 626AM satin chrome antimicrobial, and 643E aged bronze. Match the lever and finish already on your other openings and the ND82 blends into the run. 626 satin chrome is the usual commercial default, and 626AM is the same look with an antimicrobial finish for healthcare corridors. If your facility is under California fire code, note that only some of the lever designs qualify.
14) Does the ND82 accept non-Schlage cylinders if my building is keyed to another manufacturer?
Three spring cage sets are offered across the ND Series, supporting all Schlage cylinder formats plus eight competitive cylinder formats. That is how you get an ND82 onto an existing key system from another manufacturer. Be aware of the tradeoff: the beyond Grade 1 strength figures Schlage publishes apply to locks with Schlage cylinders (conventional, FSIC and SFIC), and with a non-Schlage cylinder the lock still exceeds BHMA Grade 1 but the performance may be lower.
15) What is the difference between a Schlage ND82 and a Corbin Russwin CL3110?
Function, not grade. Both are Grade 1 cylindrical lever locks, and the Corbin Russwin CL3110 is fire rated with a 1-3/4 inch to 2 inch door thickness range. The CL3110 is a passage/closet lock in the CL3100 Series, so it is non-keyed and the levers always retract the latch. The Schlage ND82 is keyed, with a double cylinder keyed function and both levers fixed. If a door needs to stay secured from both sides, the CL3110 does not do that job.
16) Can a Falcon K101 or T101 be used in place of a Schlage ND82?
Only where the opening does not need to lock. The Falcon K101 is a Grade 1 heavy duty passage cylindrical lock, fire rated, non-handed, with a 1-3/8 inch to 2-1/4 inch door thickness range, and the Falcon T101 is a Grade 1 heavy duty passage lever with pressure release technology. Both are passage function and non-keyed. The Schlage ND82 is a heavy duty Grade 1 keyed lock in the asylum, institution and utility function, also non-handed. Same grade and duty class, different job.
17) I need a storeroom lever on a budget for a utility room - what are the options against a Schlage ND82?
The Cal-Royal AG05 is a Grade 2 storeroom lever lockset with a deadlocking latchbolt for 1-3/8 inch to 1-3/4 inch doors, and the Hager 2580 is a Grade 2 storeroom cylindrical lock with the Withnell lever for 1-3/8 inch to 2 inch doors. Both are storeroom function, so the outside lever stays locked and a key retracts the latch from outside only. The Schlage ND82 is Grade 1 with a key required from either side, which is what an asylum or utility function calls for when the room has to stay controlled from both directions.
18) Which Grade 1 lever locks work with small format interchangeable cores like a Schlage ND82 BD?
The BEST 9K Series is the direct SFIC family peer - the 9K 1DT single dummy trim is a Grade 1 heavy duty cylindrical lever in that series, though the dummy has no chassis and no keying. The Schlage ND82 handles interchangeable cores through its cylinder options: BD is furnished less SFIC cylinder and JD is a Schlage FSIC prep less core, with LD less cylinder and PD a conventional 6-pin in the Schlage C keyway. Ordering BD or JD means the core is supplied separately by whoever holds the key system.
19) What looks like a substitute for a Schlage ND82 but will not work on an institutional door?
Dummy trims and residential-grade levers. The BEST 7KC Series single dummy trim is Grade 2 medium duty and the Accentra 455LN Augusta is a Grade 1 single dummy - both are dummy function with no latch and no locking. The Kwikset 200BRNL Breton is a Grade 3 passage lever for 1-3/8 inch to 1-3/4 inch doors, and the Cal-Royal AUS00 is a Grade 3 entrance/office lever. The Schlage ND82 is a commercial Grade 1 heavy duty keyed lock in zinc and steel. A Grade 3 lever will not hold up to institutional traffic and a dummy will not secure anything.
20) If the opening needs electric access control instead of a mechanical double cylinder lock, what replaces a Schlage ND82?
The Corbin Russwin CL33903 is the electrified peer - a Grade 1 fail safe electrified cylindrical lever lock operating on 12V AC/DC, for doors 1-3/4 inch to 2 inch, offered with the NZ lever and D rose. The Schlage ND82 is a mechanical lock with no electronic option, keyed from both sides. Schlage's own electrified route is within the ND Series, which carries four electrified functions that auto-detect 12/24V DC with a 0.4 amp maximum draw.
21) Can Yale or Accentra hardware be keyed to the same Schlage key as an ND82?
The Accentra 107S is a Schlage cylinder adapter kit for Yale hardware, Grade 1, which is how Yale-branded hardware gets brought onto a Schlage cylinder. The Schlage ND82 in the PD configuration ships with a conventional 6-pin cylinder in the Schlage C keyway and takes S123 cylinders and keyways, and can be ordered keyed alike across multiple locks. That combination is what lets a mixed-brand facility run one key system.
22) Will Schlage ND82 locks match the exit devices and Grade 2 locks elsewhere in my building?
Aesthetically, yes. The ND Series lever and rose designs suite with Von Duprin exit devices and other Schlage products, and they are matched to the Schlage ALX Series Grade 2 locks. That is the usual pattern in a mixed facility: ND Grade 1 on the high traffic and institutional openings, ALX Grade 2 on the lighter interior doors, same lever design and same finish throughout so the building reads as one specification.
23) Is a Design Hardware X75 the same class of lever as a Schlage ND82?
Same grade, different function. The Design Hardware X75 is a Grade 1 passage lever lockset in the X Series with a flat lever, built for 1-3/4 inch doors; the Design Hardware J75 is the Grade 2 version of that passage lever, also for 1-3/4 inch doors. The Schlage ND82 is Grade 1 and also sized around a 1-3/4 inch door, but it is a keyed cylindrical lock with two keys supplied per lock and nine lever designs including Athens, Rhodes, Sparta, Omega and Tubular. The X75 latches the door; it does not key it.
How fast can I get the Schlage ND82PD RHO 626 delivered?
Most orders ship the same day from our distribution partners, with quick delivery throughout the continental U.S. Need it urgently? Contact Us for expedited shipping options.
Can I return it if it doesn’t work for me?
Yes—ZenSupply offers a hassle-free return policy. If the product isn’t the right fit, reach out to our support team for a return authorization or setup a return by following our return instructions.
Does the Schlage ND82PD RHO 626 come with a warranty?
Absolutely. The Schlage ND82PD RHO 626 is backed by a manufacturer’s warranty. For full warranty terms, check the product documentation or Contact Us.
How do I get technical support or installation help for the Schlage ND82PD RHO 626?
You can call, text, or email our expert support team for fast answers. We’re here to help with product selection, installation tips, and troubleshooting. Contact Us
Why buy the Schlage ND82PD RHO 626 from ZenSupply?
ZenSupply makes it easy to get the commercial door hardware you need—fast shipping, expert support, and rewards on every order. Our team is always ready to help you choose the right product for your project.

Videos