Shop all Eaton
-
-
Eaton Z52G28T45CU Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, copper, 244H, 60 Hz, three-phase, 460 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 66I
Model: EAT-Z52G28T45CU
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, copper, 244H, 60 Hz, three-phase, 460 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 66IEaton
$47,101.04$47,051.04 -
-
-
Eaton Z48G28T45CUS6 Hazardous location encapsulated transformer, 45 KVA Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, 3PH, 480V DELTA-208Y/120V, 115C Rise, Copper windings, 316SS NEMA 3R Enlosure
Model: EAT-Z48G28T45CUS6
Eaton Hazardous location encapsulated transformer, 45 KVA Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, 3PH, 480V DELTA-208Y/120V, 115C Rise, Copper windings, 316SS NEMA 3R EnlosureEaton
$38,067.00$38,017.00 -
Eaton Z48E47T03SS4X Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, aluminum, NEMA 4X, 60 Hz, 3PH, 480 V, 480Y/277 V, 1 at +5% FCAN 1 at -5% FCBN, 150 °C rise
Model: EAT-Z48E47T03SS4X
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, aluminum, NEMA 4X, 60 Hz, 3PH, 480 V, 480Y/277 V, 1 at +5% FCAN 1 at -5% FCBN, 150 °C riseEaton
$6,265.84$6,215.84 -
Eaton Y48N47T30CU General purpose encapsulated transformer, EPT, copper, 243, 60 Hz, three-phase, 480 V, 480Y/277 V, None, 115 °C rise, 30 KVA, indoor-outdoor, 790A
Model: EAT-Y48N47T30CU
Eaton General purpose encapsulated transformer, EPT, copper, 243, 60 Hz, three-phase, 480 V, 480Y/277 V, None, 115 °C rise, 30 KVA, indoor-outdoor, 790AEaton
$26,319.63$26,269.63 -
Eaton Y48M47T15SS General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 95, 60 Hz, three-phase, 480 V, 480Y/277 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 15 KVA, indoor-outdoor, 84A
Model: EAT-Y48M47T15SS
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 95, 60 Hz, three-phase, 480 V, 480Y/277 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 15 KVA, indoor-outdoor, 84AEaton
$15,287.66$15,237.66 -
Eaton Y48M28T75SS Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 75 kva, al windings, frame: 245, indoor-outdoor
Model: EAT-Y48M28T75SS
Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 75 kva, al windings, frame: 245, indoor-outdoorEaton
$44,910.51$44,860.51 -
-
Eaton Y48M34B30CU General purpose encapsulated transformer, EPT, copper, NEMA 3R, 243, 60 Hz, three-phase, 480 V, 400Y/231 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 80 °C rise, 30 KVA, indoor-outdoor, 84A
Model: EAT-Y48M34B30CU
Eaton General purpose encapsulated transformer, EPT, copper, NEMA 3R, 243, 60 Hz, three-phase, 480 V, 400Y/231 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 80 °C rise, 30 KVA, indoor-outdoor, 84AEaton
$30,285.76$30,235.76 -
Eaton Z48N11S15CUS6 Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPZ, Single-phase, Primary voltage: 480V, Taps: None, Secondary voltage: 120/240V, 115°C, 15 kVA, Copper windings, FR180H, 524H, Indoor-Outdoor, 60 Hz, NEMA
Model: EAT-Z48N11S15CUS6
Eaton Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPZ, Single-phase, Primary voltage: 480V, Taps: None, Secondary voltage: 120/240V, 115°C, 15 kVA, Copper windings, FR180H, 524H, Indoor-Outdoor, 60 Hz, NEMA 3REaton
$11,250.03$11,200.03 -
Eaton Y60G28T09N General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 103, 60 Hz, three-phase, 600 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 9 KVA, indoor-outdoor, 70B
Model: EAT-Y60G28T09N
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 103, 60 Hz, three-phase, 600 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 9 KVA, indoor-outdoor, 70BEaton
$8,059.80$8,009.80 -
Eaton Y48M28T45N Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 45 kva, al windings, frame: 244, indoor-outdoor.
Model: EAT-Y48M28T45N
Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 45 kva, al windings, frame: 244, indoor-outdoor.Eaton
$20,035.76$19,985.76 -
-
Eaton Y48J28T15CUS64X General-purpose encapsulated transformer Three-phase 480V 4 at -2.5% FCBN 208Y/120V 115°C 15 kVA Copper windings 1034X 503A Indoor-Outdoor 60 Hz NEMA 4X
Model: EAT-Y48J28T15CUS64X
General-purpose encapsulated transformer Three-phase 480V 4 at -2.5% FCBN 208Y/120V 115°C 15 kVA Copper windings 1034X 503A Indoor-Outdoor 60 Hz NEMA 4XEaton
$34,237.83$34,187.83 -
-
Eaton Y85N22F06XES General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 96, 50-60 Hz, three-phase, 380 V, 400 V, 415 V, 440 V, 460 V, 480 V, 240 V, 120 V, NONE, 115 °C rise, 6 KVA, indoor-outdoor, S452N2
Model: EAT-Y85N22F06XES
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 96, 50-60 Hz, three-phase, 380 V, 400 V, 415 V, 440 V, 460 V, 480 V, 240 V, 120 V, NONE, 115 °C rise, 6 KVA, indoor-outdoor, S452N2Eaton
$14,533.87$14,483.87 -
Eaton Z48N11S01A hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, epz, single-phase, pv: 480v, taps: none, sv: 120/240v, 115°c, 1 kva, al windings, frame: 59h, indoor-outdoor
Model: EAT-Z48N11S01A
Eaton hazardous location encapsulated transformer, Eaton class 1 division 2 groups c and d, hazardous location transformer, epz, single-phase, pv: 480v, taps: none, sv: 120/240v, 115°c, 1 kva, al windings, frame: 59h, indoor-outdoorEaton
$979.49$929.49 -
-
-
Eaton Z44D14B15CU Class 1 Div. 2 Groups A, B, C, and D Hazard Location Transformer, EPZ, Single-phase, Prim. voltage: 440V, Taps: 2 at +2.5% FCAN, 2 at -2.5% FCBN, Sec. voltage: 110/220V, 80°C, 15 kVA, Cu windings, FR180H, 16C, Indoor-Outdoor, 60 Hz,
Model: EAT-Z44D14B15CU
Class 1 Div. 2 Groups A, B, C, and D Hazard Location Transformer, EPZ, Single-phase, Prim. voltage: 440V, Taps: 2 at +2.5% FCAN, 2 at -2.5% FCBN, Sec. voltage: 110/220V, 80°C, 15 kVA, Cu windings, FR180H, 16C, Indoor-Outdoor, 60 Hz, NEMA 3REaton
$12,135.84$12,085.84 -
Eaton Z16N14S25CUSS Hazardous location encapsulated transformer, Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, Single-phase, PV: 220 X 440V, Taps: None, SV: 110/220V, 115°C, 25 kVA, Cu windings, Frame: 182H, Indoor-Outdoor
Model: EAT-Z16N14S25CUSS
Eaton Hazardous location encapsulated transformer, Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, Single-phase, PV: 220 X 440V, Taps: None, SV: 110/220V, 115°C, 25 kVA, Cu windings, Frame: 182H, Indoor-OutdoorEaton
$19,859.37$19,809.37 -
Eaton Z52G23T06 Hazardous location encapsulated transformer, eptz, NEMA 3R, Frame 200H, 60 Hz, three-phase, 460 V, 230 V, 2@-5%, 115 °C rise, 6
Model: EAT-Z52G23T06
Eaton Hazardous location encapsulated transformer, eptz, NEMA 3R, Frame 200H, 60 Hz, three-phase, 460 V, 230 V, 2@-5%, 115 °C rise, 6Eaton
$6,141.46$6,091.46