Shop all Eaton
-
Eaton Y48N47T30 General purpose encapsulated transformer, EPT, aluminum, 243, 60 Hz, three-phase, 480 V, 480Y/277 V, None, 115 °C rise, 30 KVA, indoor-outdoor, 790A
Model: EAT-Y48N47T30
Eaton General purpose encapsulated transformer, EPT, aluminum, 243, 60 Hz, three-phase, 480 V, 480Y/277 V, None, 115 °C rise, 30 KVA, indoor-outdoor, 790AEaton
$18,352.09$18,302.09 -
Eaton Y48G51T15A General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 95, 60 Hz, three-phase, 480 V, 416Y/240 V, 2 at -5% FCBN, 115 °C rise, 15 KVA, indoor-outdoor, 70S
Model: EAT-Y48G51T15A
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 95, 60 Hz, three-phase, 480 V, 416Y/240 V, 2 at -5% FCBN, 115 °C rise, 15 KVA, indoor-outdoor, 70SEaton
$12,603.63$12,553.63 -
Eaton Z48G28T45CU Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, copper, 244H, 60 Hz, three-phase, 480 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 66A
Model: EAT-Z48G28T45CU
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPTZ, copper, 244H, 60 Hz, three-phase, 480 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 66AEaton
$28,571.86$28,521.86 -
Eaton Y48M48T45CU General purpose encapsulated transformer, EPT, copper, NEMA 3R, 244, 60 Hz, three-phase, 480 V, 480 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 85A
Model: EAT-Y48M48T45CU
Eaton General purpose encapsulated transformer, EPT, copper, NEMA 3R, 244, 60 Hz, three-phase, 480 V, 480 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 85AEaton
$33,329.07$33,279.07 -
Eaton Z48G22T45A Hazardous location encapsulated transformer Class 1 Division 2 Groups A,B,C and D,Hazardous Location Transformer,EPTZ,Three-phase,PV: 480V,Taps: 2 at -5% FCBN,SV: 240 delta/120 midtap,115°C,45 kVA,Al windings,Frame:244H,Indoor-Outdoo
Model: EAT-Z48G22T45A
Eaton Hazardous location encapsulated transformer Class 1 Division 2 Groups A,B,C and D,Hazardous Location Transformer,EPTZ,Three-phase,PV: 480V,Taps: 2 at -5% FCBN,SV: 240 delta/120 midtap,115°C,45 kVA,Al windings,Frame:244H,Indoor-OutdoorEaton
$20,960.57$20,910.57 -
Eaton Z48E28T30CUSS Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPTZ, copper, NEMA 3R, 243H, 60 Hz, three-phase, 480 V, 208Y/120 V, 1 at +5% FCAN, 1 at -5% FCBN, 115 °C rise
Model: EAT-Z48E28T30CUSS
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPTZ, copper, NEMA 3R, 243H, 60 Hz, three-phase, 480 V, 208Y/120 V, 1 at +5% FCAN, 1 at -5% FCBN, 115 °C riseEaton
$31,611.51$31,561.51 -
Eaton Y48M25T45CU General purpose encapsulated transformer, EPT, copper, 244, 60 Hz, three-phase, 480 V, 220 V, 2 at +2.5% FCAN 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 85A
Model: EAT-Y48M25T45CU
Eaton General purpose encapsulated transformer, EPT, copper, 244, 60 Hz, three-phase, 480 V, 220 V, 2 at +2.5% FCAN 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 85AEaton
$33,012.07$32,962.07 -
Eaton Y60G28T03CU General purpose encapsulated transformer, EPT, copper, NEMA 3R, 201, 60 Hz, three-phase, 600 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 3 KVA, indoor-outdoor, 70B
Model: EAT-Y60G28T03CU
Eaton General purpose encapsulated transformer, EPT, copper, NEMA 3R, 201, 60 Hz, three-phase, 600 V, 208Y/120 V, 2 at -5% FCBN, 115 °C rise, 3 KVA, indoor-outdoor, 70BEaton
$8,792.46$8,742.46 -
Eaton Z48N11S15CU Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPZ, Single-phase, Primary voltage: 480V, Taps: None, Secondary voltage: 120/240V, 115°C, 15 kVA, Copper windings, FR180H, 524H, Indoor-Outdoor, 60 Hz, NEMA 3R
Model: EAT-Z48N11S15CU
Eaton Class 1 Division 2 Groups A, B, C, and D Hazardous Location Transformer, EPZ, Single-phase, Primary voltage: 480V, Taps: None, Secondary voltage: 120/240V, 115°C, 15 kVA, Copper windings, FR180H, 524H, Indoor-Outdoor, 60 Hz, NEMA 3R.Eaton
$8,889.90$8,839.90 -
Eaton Z48G37T50 Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 380Y/220V, 115°C, 50 kVA, Aluminum windings, FR245H, 66A, Indoor-Outdoor, 60 Hz
Model: EAT-Z48G37T50
Eaton Class 1 Div. 2 Groups A, B, C, and D Hazardous Location Transformer, EPTZ, Three-phase, Primary voltage: 480V, Taps: 2 at -5% FCBN, Secondary voltage: 380Y/220V, 115°C, 50 kVA, Aluminum windings, FR245H, 66A, Indoor-Outdoor, 60 HzEaton
$24,822.33$24,772.33 -
Eaton Y48M38T75 General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 245, 60 Hz, three-phase, 480 V, 380 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 75 KVA, indoor-outdoor, 85A
Model: EAT-Y48M38T75
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 245, 60 Hz, three-phase, 480 V, 380 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 75 KVA, indoor-outdoor, 85AEaton
$36,978.21$36,928.21 -
Eaton Y48M28T45CUX General purpose encapsulated transformer, EPT, copper, NEMA 3R, 244, 50-60 Hz, three-phase, 480 V, 208Y/120 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 84A
Model: EAT-Y48M28T45CUX
Eaton General purpose encapsulated transformer, EPT, copper, NEMA 3R, 244, 50-60 Hz, three-phase, 480 V, 208Y/120 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 45 KVA, indoor-outdoor, 84AEaton
$37,985.61$37,935.61 -
-
Eaton ZN400 Old Line Neutral/Ground
Model: EAT-ZN400
Warranties Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Certifications CSA Certified UL 857 IEEE...Eaton
$1,392.14$1,342.14 -
Eaton Y72M34T25X General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 243, 50-60 Hz, three-phase, 200 V, 400Y/231 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 25 KVA, indoor-outdoor, 48C
Model: EAT-Y72M34T25X
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 243, 50-60 Hz, three-phase, 200 V, 400Y/231 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 115 °C rise, 25 KVA, indoor-outdoor, 48CEaton
$25,939.21$25,889.21 -
Eaton Z48N11B15CU Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPZ, copper, NEMA 3R, 180H, 60 Hz, single-phase, 480 V, 120/240 V, NONE, 80 °C rise, 15 KVA, indoor-outdoor, 524H
Model: EAT-Z48N11B15CU
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPZ, copper, NEMA 3R, 180H, 60 Hz, single-phase, 480 V, 120/240 V, NONE, 80 °C rise, 15 KVA, indoor-outdoor, 524HEaton
$11,250.03$11,200.03 -
Eaton Y48M28B45CUESLS45 General purpose encapsulated transformer, EPT, copper, NEMA 3R, 245, 60 Hz, low sound 45 dB, three-phase, 480 V, 208Y/120 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 80 °C rise, 45 KVA, indoor-outdoor, 500A
Model: EAT-Y48M28B45CUESLS45
Eaton General purpose encapsulated transformer, EPT, copper, NEMA 3R, 245, 60 Hz, low sound 45 dB, three-phase, 480 V, 208Y/120 V, 2 at +2.5% FCAN, 4 at -2.5% FCBN, 80 °C rise, 45 KVA, indoor-outdoor, 500AEaton
$46,946.43$46,896.43 -
Eaton Z12N29S02 Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPZ, aluminum, 68H, 60 Hz, three-phase, 120 V, 208 V, None, 115 °C rise, 2 KVA, indoor-outdoor, 519X
Model: EAT-Z12N29S02
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups a b c and d hazardous location transformer, EPZ, aluminum, 68H, 60 Hz, three-phase, 120 V, 208 V, None, 115 °C rise, 2 KVA, indoor-outdoor, 519XEaton
$1,658.41$1,608.41 -
Eaton Y48M28T75N Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 75 kva, al windings, frame: 245, indoor-outdoor.
Model: EAT-Y48M28T75N
Eaton, general purpose encapsulated transformer, ept, three-phase, pv: 480v, taps: 2 at +2.5% fcan, 4 at -2.5% fcbn, sv: 208y/120v, 115°c, 75 kva, al windings, frame: 245, indoor-outdoor.Eaton
$32,173.74$32,123.74 -
Eaton Z38M62T30CU Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 380V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 460Y/266V, 115°C, 30 kVA, Cu windings, Frame: 243, Indoor-Outdoor
Model: EAT-Z38M62T30CU
Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 380V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 460Y/266V, 115°C, 30 kVA, Cu windings, Frame: 243, Indoor-OutdoorEaton
$28,283.66$28,233.66 -
Eaton Z48N28T03CU Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPTZ, copper, NEMA 3R, 201H, 60 Hz, three-phase, 480 V, 208Y/120 V, NONE, 115 °C rise, 3 KVA, indoor-outdoor, 71A
Model: EAT-Z48N28T03CU
Eaton Hazardous location encapsulated transformer, class 1 division 2 groups c and d, hazardous location transformer, EPTZ, copper, NEMA 3R, 201H, 60 Hz, three-phase, 480 V, 208Y/120 V, NONE, 115 °C rise, 3 KVA, indoor-outdoor, 71AEaton
$3,502.23$3,452.23 -
Eaton Z48G28T45A Hazardous location encapsulated transformer, Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 208Y/120V, 115°C, 45 kVA, Al windings, Frame: 244, Indoor-Outdoor
Model: EAT-Z48G28T45A
Eaton Hazardous location encapsulated transformer, Class 1 Division 2 Groups A, B, C, D Hazardous Location Transformer, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 208Y/120V, 115°C, 45 kVA, Al windings, Frame: 244, Indoor-OutdoorEaton
$19,064.57$19,014.57 -
Eaton Y48G51T09A General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 103, 60 Hz, three-phase, 480 V, 416Y/240 V, 2 at -5% FCBN, 115 °C rise, 9 KVA, indoor-outdoor, 70S
Model: EAT-Y48G51T09A
Eaton General purpose encapsulated transformer, EPT, aluminum, NEMA 3R, 103, 60 Hz, three-phase, 480 V, 416Y/240 V, 2 at -5% FCBN, 115 °C rise, 9 KVA, indoor-outdoor, 70SEaton
$10,053.44$10,003.44 -
Eaton Z48G22T30SS Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 240 delta/120 midtap, 150°C, 30 kVA , Al windings, Frame: 243H, Indoor-Outdoor
Model: EAT-Z48G22T30SS
Class 1 Division 2 Groups C and D, Hazardous Location Transformer, EPTZ, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 240 delta/120 midtap, 150°C, 30 kVA , Al windings, Frame: 243H, Indoor-OutdoorEaton
$23,790.91$23,740.91